Automated POCT HbA1c Analyzer Whole blood Sample For Glycated Hemoglobin Test

Price Negotiable
Price: Negotiation
MOQ: 1
Delivery Time: 15-20 working days
Brand: LABNOVATION
Product Description

Automated POCT HbA1c Analyzer For Glycated Hemoglobin Test

 

Intended Use

 

Automated POCT HbA1c Analyzer is a device that used for detection of glycosylated hemoglobin (HbA1c) in human blood.

The LD-100 is a one-step operation HbA1c analyzer. For the measurement of glycated hemoglobin by the well-established borate affinity method. Small amount of sample and easy operation which is aimed to help manage diabetes for patients and professionals in laboratory, clinic and hospital. Flexible workflow, easy to use with lab-quality results. LD-100 helps you to be more efficient in your lab workflow.

 

 

 

Feature

 

Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).


 

 

 

Reliable

IFCC calibrator Normal Abnormal Normal Abnormal
Mean HbA1c% 5.4 9.6 5.3 9.2
CV (%) 2.5% 1.9% 2.4% 1.8%

 

 

Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English;  Abnormal alarm function.

 

Certificate

 

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Labnovation Technologies, Inc.
Location 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Contact Person Aimee li

Request A Quote

Please check your email address.
Your message must be at least 20 characters.