Multifunctional Body Slimming Machine Vacuum Polar RF Cavitation
Body Slimming Machine Multi-functional Vacuum RF Slimming Machine Vacuum + Polar RF + Cavitation
2022 V9 New Product Vacuum Rf Cellulite Rolling Fat Removal Massage Slimming Machine
Theory
Infrared RF Vacuum technology combines infrared light, bi-polar radio frequency energy and vacuum, which cause deep heating of the fat cells, their surrounding connective tissue and the underlying dermal collagen fibers. This type of efficient heating and vacuum stimulates the growth of new and better collagen and elastin which results in localized reduction in skin laxity, body volume, and an overall improvement in skin structure and texture.
| Voltage | 220v/110v; 50Hz-60Hz |
| Screen | 8inch touch screen |
| Cavitation | 40KHz |
| Vacuum | 100Kpa |
| Energy of RF | 0-50J/cm2 |
| Monopolar | 6.8MHz |
| Bipolar RF and Three Polar RF | 5MHz |
| Vacuum RF | 5MHz |
| Power Consumption |
≤350W |
Scope of Treatment: Body contouring; Cellulite removal; Body slimming; Circumference reduction; Skin tightening; Face lifting; Wrinkle removal; Skin texture & tone.
3 Technologies in one machine - Vacuum + Polar RF + Cavitation
(1) Infrared laser reduces skin impedance by heating skin and RF energy penetrates deeply into connective tissue. The synergistic combination of infrared laser and conducted RF energies increases the oxygen intracellular diffusion by heating the skin.
(2) Vacuum plus specially designed rollers manipulate leads RF penetration to be even 5-15mm.
(3) The technology that vacuum folds skin makes RF energy penetrate a specific folded skin, greatly improve effect and safety, even for the upper eyelid area treatment.
Application:
Wrinkle removal
Body shaping
Body circumference reduction
Cellulite reduction
Skin tightening
Skin surface smooth
Massage
Eyelid area treatment
Body slimming
Skin lifting
(1) Open the package and get all the spare parts out;
(2) Connect the Vacuum Four Polar RF handle with port A;
(3) Connect the Vacuum RF handle with port B;
(4) Connect the Bipolar RF handle with port C;
(5) Connect the Three-polar RF handle with port D;
(6) Connect the 40KHz Cavitation Vela Vacuum handle with port E;
(7) Connect the Monopolar handle with port F;
(8) Connect the Electrode Plate with port G;
(9) Connect the Power Line with port H.
Product Service
(1) Warranty: The warranty date is one year from the date of purchasing. We are responsible for the maintenance in our facility in GZ. When the warranty date is expired, we will charge the service fee or the cost of the component.
(2) Professional Use: The merchandise of our Products is designed for professional use only and must be installed by a licensed professional electrician only. Failure to do so will void customer warranty.
(3) Manufacturer Defects: In the event of defects in material and workmanship our obligation shall be limited to free labor and parts repair or replacement, solely at our option, of any defective part for a period of one year from the date of purchase.
(4) Disclaimer of Damages: The remedies provided herein are the buyer’s sole and exclusive remedies and in no event shall our products be liable for direct, indirect, special, incidental, or consequential damages (including loss of profits) whether based on contract, tort, or any other legal theory.
(5) Returns: All damaged machines must return in 30 days after receiving the confirmation from our service department.
(6) Shipping Policy: For your protection, the acceptance of this shipment by the Transportation Company is an acknowledgement that the articles were delivered to them in good working condition and properly packed.
(7) Exceptions
- Inappropriate damage such as: dramatic impact, vibration, drops, condenser chamber burning, crystal rods destroying, etc.
- Inappropriate damage or loss of key components such as the handpiece, protective glasses, power lines, you will be charged for the cost of accessories.
- Consumer who repairs the machine caused by improper by himself.
- Due to irresistible forces (such as fires, earthquakes and other natural disasters) of damage.
- Beyond the period of warranty products.
9. Contraindications
(1) Polar RF
There are heart disease, self-contained heart rhythm device, and patients with hypertension. People with acute inflammation, deep venous thrombosis, goiter, asthma, cancer, etc. have ruptured blood vessels and have trauma, and the wound is bleeding. Pregnant women have undergone cosmetic surgery in areas with fillers, people with metal materials in their bodies (including metal teeth), skin inflammation, body puffiness, abnormal immune system function, and people who feel numb and do not respond to heat.
(2) Cavitation
There are heart disease, self-contained heart rhythm device, and patients with hypertension. People with acute inflammation, deep venous thrombosis, goiter, asthma, cancer, etc. have ruptured blood vessels and have trauma, and the wound is bleeding. Pregnant women. Skin has inflammation, and those with abnormal immune system function are forbidden.
(3) Vacuum RF
There are heart disease, self-contained heart rhythm device, and patients with hypertension. People with acute inflammation, deep venous thrombosis, goiter, asthma, cancer, etc. have ruptured blood vessels and have trauma, and the wound is bleeding. Pregnant women. People with inflammation of the skin, edema of the body, those with abnormal immune system functions, and those who feel numbness and do not respond to heat.
(4) Monopolar
People with heart disease or high blood pressure,or configured cardiac pacemaker.
Patients with acute inflammation,asthma, deep vein thrombosis, thyroncus,cancer.
People with hemorrhagic disease, trauma or who is bleeding.
Pregnant women.
Medical Plastic parts, or parts with artificial infilling inside.
People with metal inside the body(include metallic tooth).
Patient with skin inflammation or with edema.
People with an abnormal immune system.
Numb or insensitive to heat.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.