GXYZ-A2.5/25 High/Low Lubrication Station 25L/Min LBZ-25 1.1 KW 1450RPM

 

 

 

 

General Conditions

 

 

When the main engine is running normally, one low-pressure pump is working and the other is standby. If the system pressure drops to a certain value, the standby pump will be started and put into operation, and the standby pump will stop when the normal pressure is reached. If the pressure still drops to a lower value after the standby pump is started, an alarm signal should be sent and the main engine should be considered to stop.


When the high-pressure plunger pump fails, oil can be supplied by the standby manual oil pump.


The filter is placed in front of the cooler, so that the less viscous oil passes through the filter first to improve the filtering effect. One filter is working and the other is standby, controlled by the manual switching valve.


When the oil level of the fuel tank is too low or too high, the oil level signaler will send a signal to manually refuel or stop refueling.


There is a magnetic net filter in the oil return tank, which can filter the oil and absorb iron particles in the oil at the same time.


When the thin oil station is supplied as a complete set, it is equipped with instruments and electric control boxes to display operating parameters and realize automatic control, manual control or alarm of the thin oil station.


The oil tank is equipped with an electric contact bimetallic thermometer. When the oil temperature is low, a signal is sent to manually switch on the electric heater. When the set temperature is reached, the electric heater is automatically cut off.

 

 

Technical Details

 

 

Parameters Type GXYZ-A2.5/16 GXYZ-A2.5/25 GXYZ-A2.5/40 GXYZ-A2.5/63 GXYZ-A2.5/100 GXYZ-A2.5/125
low pressure system Pump unit model LBZ-16 LBZ-25 LBZ-40 LBZ-63 LBZ-100 LBZ-125
Flow 16L/min 25L/min 40L/min 63L/min 100L/min 125L/min
Oil supply pressure ≤0.4 MPa
Oil supply temperature 40±3
Motor Model Y90S-4,V1 Y100S-4,V1 Y112S-4,V1
Power 1.1 KW 2.2 KW 4 KW
Speed 1450 r/min 1440 r/min 1440 r/min
Fuel tank capacity m3 0.8 1.2 1.6
High pressure system Pump unit model 2.5MCY14-1B
Flow 2.5 L/min
Oil supply pressure 31.5 MPa
Motor Model Y112M-6 B35
Power 2.2 Kw
Speed 940 r/min
Filtration accuracy m2 0.08~0.12
Filter Area m2 3 5 7
Cooling Area m2 1 1.5 3.6 5.7 9 11.25
Electric heating power Kw 3 x 4 3 x 4 6 x 4
Dimension (mm) 1820 x 1130 x 1320 1880 x 1220 x 1650 2180 x 1550 x 1850
Notes All filter switching pressure difference is 0.15MPa

 

 

 

Working Principal

 

 

 

 

 

 

 

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company CDINDUSTRY(INTERNATIONAL).INC
Location RM 14-1, BUILDING 13, HUANGSHAN AVENUE YUBEI DISTRICT, CHONGQING, 401121, CHINA
Contact Person Jason

Request A Quote

Please check your email address.
Your message must be at least 20 characters.