Zhenglan Cable Technology Co., Ltd
                                                                                                           
Verified Supplier
30 Years
Since 1996
Menu
Power Cables

XLPE Insulated Overhead Insulated Cable Duplex Service Drop Cable 600 Volts

Price Negotiable
Price: negotiable
MOQ: 1000 meters
Delivery Time: 15 days
Product Description

Duplex Service Drop Cable​ 

Tags : duplex service drop cable,overhead service drop cable,service drop cable neutral supported

Summary: This duplex service cable is composed of an PE or XLPE insulated aluminum conductor and a bare AAAC, or ACSR conductor as neutral or messenger cable twisted together

 

DESCRIPTION

 

This duplex service drop cable is composed of an PE or XlPE insulated aluminum conductor and a bare AAAC, or ACSR conductor as neutral or messenger cable twisted together. It also belong to the ABC cable group, usually used from a pole mounted transformer to the service entrance of a structure, or as secondary distribution between poles. It is also used to supply 120 volts aerial service for temporary service at construction sites, outdoor or street lighting. The cable should be limited to 600V phase to phase and not exceed 90˚C.

Duplex service drop cable CONSTRUCTION

One insulated phase conductors twisted around a bare aluminum alloy or ACSR neutral conductor.

Conductors: Aluminum alloy 1350-H19 wire.

Insulation: Black thermoset cross-linked polyethylene (XLPE).

Neutral: Bare aluminum alloy or ACSR

Conductor Phase ID: Extruded ridges.

Duplex service drop cable STANDARDS

ASTM B-230: Aluminum 1350-H19 wire for electrical purposes.

ASTM B-231: Concentric lay stranded aluminum 1350 conductors.

ICEA S-76-474: Neutral supported power cable assemblies with weather resistant extruded insulation rated at 600V.

ASTM B-232: Concentric lay stranded aluminum conductors coated-steel reinforced

Duplex service drop cable Specifications

Maximum operating voltage: 600 volts

Maximum conductor operation temperatures: Wet and dry locations

PE

• Normal: 75 °C

• Emergency: 95 °C

• Short Circuit: 150 °C

XLPE

• Normal: 90 °C

• Emergency: 130 °C

• Short Circuit: 250 °C

Service Drop Cable Configurations (Assemblies):

Duplex: Consist of one black phase insulated conductor twisted around a bare neutral conductor.

Triplex: Consist of two black phase insulated conductor (Second conductor with 1 ridge) twisted around a bare neutral conductor.

Quadruplex: Consist of three black phase insulated conductor (Second conductor 1 ridge, third conductor 2 ridges) twisted around a bare neutral conductor

 

SPECIFICATIONS

Aluminum Alloy Duplex Service Drop Cable parameters

Code*word

Phase conductor

Bare Neutal messager

Weight Per 1000 ft. (lbs.)

Allowable Ampacities+

  Size(AWG)

Strand- ing

Insul. Thick. (mils)

Equiv.Dia (AWG)

Size (kcmil)

Strand- ing

Rated Strength (lbs.)

XLPE

POLY

XLPE

POLY

6201 ALLOY NEUTRAL-MESSENGER

Chihuahua

6

1

45

6

30.58

7

1110

65

65

85

70

Vizsla

6

7

45

6

30.58

7

1110

68

68

85

70

Harrier

4

1

45

4

48.69

7

1760

99

99

115

90

Whippet

4

7

45

4

48.69

7

1760

103

103

115

90

Schnauzer

2

7

45

2

77.47

7

2800

157

157

150

120

Heeler

1/0

19

60

1/0

123.3

7

4460

250

250

205

160

Code*word

Phase conductor

Bare

Neutal messager

Weight Per 1000 ft. (lbs.)

Allowable Ampacities+

  Size (AWG)

Strand- ing

Insul. Thick. (mils)

Size (AWG)

Strand- ing

Rated Strength (lbs.)

XLP

POLY

XLP

POLY

AAC NEUTRAL-MESSENGER

Pekingese

6

1

45

6

7

563

61

61

85

70

Collie

6

7

45

6

7

563

64

64

85

70

Dachshund

4

1

45

4

7

881

92

92

115

90

Spaniel

4

7

45

4

7

881

96

96

115

90

Doberman

2

7

45

2

7

1350

147

147

150

120

Malemute

1/0

19

60

1/0

7

1990

234

234

205

160

Code* word

Phase conductor

Bare Neutal messager

Weight Per 1000 ft. (lbs.)

Allowable Ampacities+

  Size (AWG)

Strand- ing

Insul. Thick. (mils)

Size (AWG)

Strand- ing

Rated Strength (lbs.)

XLP

POLY

XLP

POLY

ACSR NEUTRAL-MESSENGER

Setter

6

1

45

6

(6)/(1)

1190

72

72

85

70

Shepherd

6

7

45

6

(6)/(1)

1190

75

75

85

70

Eskimo

4

1

45

4

(6)/(1)

1860

110

110

115

90

Terrier

4

7

45

4

(6)/(1)

1860

115

115

115

90

Chow

2

7

45

2

(6)/(1)

2850

176

176

150

120

Bull

1/0

19

60

1/0

(6)/(1)

4380

280

280

205

160

Note: Designated sizes are ACSR 6/1 diameter equivalent resistivity per ASTM-B-399 for 6201. Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperatures of 40°C;

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Zhenglan Cable Technology Co., Ltd
Contact Person linda

Request A Quote

Please check your email address.
Your message must be at least 20 characters.