Zhenglan Cable Technology Co., Ltd
                                                                                                           
Verified Supplier
30 Years
Since 1996
Menu
Power Cables

CAAI Overhead Insulated Cable 0.6-1kv Low Voltage Aerial Bundled Cable

Price Negotiable
Price: negotiable
MOQ: 1000 meters
Delivery Time: 15 days
Product Description

0.6-1kv CAAI Cable

Tags : LV aerial bundled cable,LV ABC cable,1kv CAAI cable

Summary: 0.6/1kv CAAI cable also called insulated ABC Cable usually used for urban and rural overhead secondary distribution networks, with voltages up to 1000 V.

 

DESCRIPTION

 

0.6/1kv CAAI cable also called insulated ABC Cable, suitable for copper core, aluminum core or aluminum alloy core weatherproof PVC, PE and XLPE insulated overhead cable under AC rated voltage of 1kv in overhead power line. 0.6/1kv Aerial Insulated Cable consists of Aluminum, Hard Copper or Soft Copper, Aluminum alloy Core, PVC/PE/XLPE Insulation.

0.6/1kv CAAI cable Construction:

1. Conductor: Aluminium 1350, class 2.

2. Insulation: Cross linked polyethylene XLPE.

3. Public lighting: Aluminium 1350 insulated with cross-linked polyethylene XLPE.

4. Insulated neutral messenger: AAAC - All Alloy Aluminium 6201 - XLPE.

5. Core identification: rib markings

0.6/1kv CAAI cable reference STANDARDS

IEC 60228; IEC 60811-201; IEC 60811-401; IEC 60811-402; IEC 60811-501; IEC 60811-502; IEC 60811-507; IEC 60811-511; ASTM B 231; ICEA S-76-474;

NTP 370.254; NTP 370.258; NTP-IEC 60228; NFC 33-209

Marking:

(Nb. Cores x Section) + (Nb. conductors x public lighting section) + NA(Neutral messenger section) - Year - Sequential length.

0.6/1kv CAAI cable Application:This cable usually used for urban and rural overhead secondary distribution networks, with voltages up to 1000 V. They permit longer spans, lower mounting, minimum support, and simplified installation, particularly among trees or in congested areas. It also offers maximum personnel safety and protection against outage. Resistance to abrasion, flexing, and effects of heat, moisture, sunlight and cold assure high dependability through long years of services.

 

SPECIFICATIONS

0.6/1kv CAAI cable Parameters

DESCRIPTION INSULATED CONDUCTORS   CABLE BUNDLE
Type Nominal Cross Section Wire Number Maximum Resistance at 20 ℃ Average Diameter of Conductors Rated Strength Average insulation Thickness Overall Diameter
mm2 Minimum Ohm/km Min.mm Max.mm Min kN mm Min. mm Max.mm
Phase neutral and public lighting 16 7 1.91 4.6 5.1 1.9 1.2 7 7.8
25 7 1.2 5.8 6.3 3 1.4 8.6 9.4
35 7 0.868 6.8 7.3 - 1.6 10 10.9
50 7 0.641 7.9 8.4 - 1.6 11.1 12
70 12 0.443 9.7 10.2 - 1.8 13.3 14.2
95 19 0.32 11 12 - 1.8 14.6 15.7
120 19 0.253 12 13.1 - 1.8 15.6 16.7
150 19 0.206 13.9 15 - 1.7 17.3 18.6
Porter 54.6 7 0.63 9.2 9.6 16.6 1.6 12.3 13
70 7 0.5 10 10.2 20.5 1.5 12.9 13.6
95 19 0.343 12.2 12.9 27.5 1.6 15.3 16.3
Nominal Area

Number /Dia.

Insulation Thickness

Dcresistance PHASE

NEUTRAL Rated Strength kn

Delivery Lerngth

mm2

mm

mm

& Ω /km

AAC

AAAC

km

1×16+16

7/1.70

1.3

1.7986

3.02

4.69

10

2×16+16

7/1.70

1.3

1.7986

3.02

4.69

7.5

3×16+16

7/1.70

1.3

1.7986

3.02

4.69

5

4×16

7/1.70

1.3

1.7986

3.02

4.69

5

1×25+25

7/2.10

1.3

1.1787

4.36

7.15

6.5

2×25+25

7/2.10

1.3

1.1787

4.36

7.15

5

3×25+25

7/2.10

1.3

1.1787

4.36

7.15

3.2

4×25

7/2.10

1.3

1.1787

4.36

7.15

3.2

1×35+35

7/2.50

1.3

0.8317

6.01

10.14

4.5

2×35+35

7/2.50

1.3

0.8317

6.01

10.14

3.5

3×35+35

7/2.50

1.3

0.8317

6.01

10.14

2.2

4×35

7/2.50

1.3

0.8317

6.01

10.14

2.2

1×50+50

7/3.0

1.5

0.5776

8.41

14.6

3

3×50+50

7/3.0

1.5

0.5776

8.41

14.6

1.3

1×70+70

19/2.10

1.5

0.4367

11.85

19.41

2.2

3×70+70

19/2.10

1.5

0.4367

11.85

19.41

0.8

3×95+95

19/2.50

1.6

0.3081

16.32

27.51

0.5

Code Word 3×25mm2+1×54.6mm2 3×35mm2+1×54.6mm2 3×50mm2+1×54.6mm2 3×70mm2+1×54.6mm2 3×35mm2+1×54.6mm2+1×16mm2 3×70mm2+1×54.6mm2+1×16mm2 3×70+1×70mm2
Phase Conductor Cross Section (mm) 25 35 50 70 35 70 70
Number of Wires 7 7 7 12 7 12 12
Insulation Thickness (mm) 1.4 1.6 1.6 1.8 1.6 1.8 1.8
D.C.Resistance At 20 ℃(Ohm/km) 1.2 0.868 0.641 0.443 0.868 0.443 0.443
Minium Rated Strength(daN) 300 - - - - - -
Messenger Cross Section (mm) 54.6 54.6 54.6 54.6 54.6 54.6 70
Number of Wires 7 7 7 7 7 7 7
Insulation Thickness (mm) 1.6 1.6 1.6 1.6 1.6 1.6 1.5
D.C.Resistance A 20 ℃( Ohm/km) 0.63 0.63 0.63 0.63 0.63 0.63 0.5
Minium Rated Strength(daN) 1660 1660 1660 1660 1660 1660 2050
Public Lighting Cross Section (mm) - - - - 16 16 -
Number of Wires - - - - 7 7 -
Insulation Thickness (mm) - - - - 1.2 1.2 -
D.C.Resistance At 20 ℃(Ohm/km) - - - - 1.91 1.91 -
Minium Rated Strength(daN) - - - - 190 190 -
Conductor Diameter Phase Max 6.3 7.3 8.4 10.2 7.3 10.2 10.2
  Min 5.8 6.8 7.9 9.7 6.8 9.7 9.7
Messenger Max - - - - 5.1 5.1 -
  Min - - - - 4.6 4.6 -
Public Lighting Max - - - - 5.1 5.1 -
  Min - - - - 4.6 4.6 -
Overall Diameter Phase Max 9.4 10.9 12 14.2 10.9 14.2 14.2
  Min 8.6 10 11.1 13.3 10 13.3 13.3
Messenger Max 13 13 13 13 13 13 13.6
  Min 12.3 12.3 12.3 12.3 12.3 12.3 12.9
Public Lighting Max - - - - 7.8 7.8 -
  Min - - - - 7 7 -
Code Word 3×70mm2+1×16mm2 3×95mm2+1×70mm2 3×95mm2+ 1×70+ 1×16mm2 3×120mm2+1×70mm2 3×120mm2+1×70+1×16mm2 3×150mm2+1×70mm2 3×70mm2+1×70mm2+1×16mm2
Phase Conductor Cross Section (mm) 70 95 95 120 120 150 150
Number of Wires 12 19 19 19 19 19 19
Insulation Thickness (mm) 1.8 1.8 1.8 1.8 1.8 1.7 1.7
D.C.Resistance At 20 ℃( Ohm/km) 0.443 0.32 0.32 0.253 0.253 0.206 0.206
Minium Rated Strength(daN) - - - - - - -
Messenger Cross Section (mm) 70 70 70 70 70 70 70
Number of Wires 7 7 7 7 7 7 7
Insulation Thickness (mm) 1.5 1.5 1.5 1.5 1.5 1.5 1.5
D.C.Resistance At 20 ℃( Ohm/km) 0.5 0.5 0.5 0.5 0.5 0.5 0.5
Minium Rated Strength(daN) 2050 2050 2050 2050 2050 2050 2050
Public Lighting Cross Section (mm) 16 - 16 - 16 - 16
Number of Wires 7 - 7 - 7 - 7
Insulation Thickness (mm) 1.2 - 1.2 - 1.2 - 1.2
D.C.Resistance At 20 ℃( Ohm/km) 1.91 - 1.91 - 1.91 - 1.91
Minium Rated Strength(daN) 190 - 190 - 190 - 190
Conductor Diameter Phase Max 10.2 12 12 13.1 13.1 15 15
  Min 9.7 11 11 12 12 13.9 13.9
Messenger Max 10.2 10.2 10.2 10.2 10.2 10.2 10.2
  Min 10 10 10 10 10 10 10
Public Lighting Max 5.1 - 5.1 - 5.1 5.1 5.1
  Min 4.6 - 4.6 - 4.6 4.6 4.6
Overall Diameter Phase Max 14.2 15.7 15.7   16.7 16.7 18.6
  Min 13.3 14.6 14.6   15.6 15.6 17.3
Messenger Max 13.6 13.6 13.6   13.6 13.6 13.6
  Min 12.9 12.9 12.9   12.9 12.9 12.9
Public Lighting Max 7.8 - 7.8   7.8 7.8 7.8
  Min 7 - 7   7 7
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Zhenglan Cable Technology Co., Ltd
Contact Person linda

Request A Quote

Please check your email address.
Your message must be at least 20 characters.