KFZ-I Power Transformer Capacity, Load and No Load Loss Tester
Introduction:
- Power transformers an important electrical equipment, and their safe and reliable operation is extremely important for power systems.
- After the impact of a short-circuit current, the transformer winding deformation test is very important.
- To short-circuit the low-voltage winding side of the transformer and apply a low voltage of the operating frequency (50Hz or 60Hz normally) to the high-voltage winding side of the transformer, the short-circuit impedance method measures the short-circuit impedance of the operating frequency.
- The test result is mainly leakage reactance component, determined by the geometry of the winding.
- The change of the transformer winding structure will cause changes in the transformer leakage reactance, resulting in transformer short circuit impedance numerical changes.
- KFZ Power Transformer Excitation Current, Capacity, Load Loss Tester follows the national power industry standards DLT 1093-2008, and can be used for IEC60076-5-2006.
- KFZ Power Transformer Excitation Current, Capacity, and Load Loss Tester can also be used for generator rotor AC impedance test, transformer load, and no load loss test.
Specifications:
-
Using six channels of AD chip of 16 bits;
-
With a 7-inch LCD touch screen which the brightness can be adjusted;
-
With a thermal printer the print thick can be adjusted;
-
It could store fifty groups of SCI data and thirty groups of GAI data, which could be read to the current screen or uploaded to the PC;
-
With PC software using which we could upload data, test, analyze data, print data, or create Word document;
-
Using USB2.0 to connect to the device;
-
Tester dimension: 49*31*25cm;
-
Weight: 8.0KG;
-
Power: AC220V±10%, (50 or 60)HZ ;
| 1 | Working power | Input voltage | 185Vac~250Vac |
| Allowable input voltage | 85Vac~264Vac | ||
| Frequency | 50/60Hz | ||
| Allowable frequency | 45Hz~65Hz | ||
| Input power | 40VA | ||
| 2 | AC voltage | Range | 10~650V |
| Resolution | 0.001V | ||
| Accuracy | 0.2%±0.001V | ||
| 3 | AC Current | Range | 0.5~60A |
| Resolution | 0.001A | ||
| Accuracy | 0.2%±0.001A | ||
| 4 | Frequency | Range | 45Hz~65Hz |
| Resolution | 0.001Hz | ||
| Accuracy | 0.2%±0.001Hz | ||
| 5 | Power | Range | 0~39kW |
| Resolution | 0.001kW | ||
| Accuracy | <±0.5% | ||
| 6 | Capacity test range | 10kV Dry type transformer | 30kVA~3150kVA |
| 10kV Oil immersed transformer | 30kVA~3150kVA | ||
| 35kV Oil immersed transformer | 50kVA~31500kVA | ||
| 20kV Dry type transformer | 50kVA~2500kVA | ||
| 35kV Dry type transformer | 50kVA~2000kVA | ||
| 7 | Environment | Operating temperature | -10℃~+50℃ |
| Storage temperature | -25℃~+70℃ | ||
| Relative humidity | 5%~95% | ||
| 8 | Dimension | 40cm*30cm*22cm | |
| 9 | Weight | ≈8kg (Excluding accessories) | |