CPT-III Single Phase or Three Phase Portable Current Transformer Tester
Price:
USD1.0
MOQ:
1 set Current Transformer Tester
Delivery Time:
10 days
Product Description
CPT-III Single Phase or Three Phase Current Transformer Tester
Application:
Tests for current transformer:
- Excitation curve and parameters test
- Turns ratio test
- Ratio and phase error test
- Polarity mark check
- Winding resistance measurement
- Secondary loop burden measurement
- Error line curve test for protection CT
- Transient CT parameters test
- CT nameplate guess
- Saturation hysteresis loop curve measurement
Tests for voltage transformer:
- Turns ratio test
- Ratio error and phase angle error test
- Polarity test
- Secondary burden test
- Winding resistance test
Applications for Transformer Tester:
- CT nameplate check
- CT parameters check in work burden
- CT transient parameters analysis
- CT ratio and phase error calibration
-
PT routine test
Parameters:
| No. | Item Name | CPT-III Portable Current Transformer Tester |
| 1 | Test standards | IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13 |
| 2 | Power supply | AC220V±10%,50Hz/60Hz±10% |
| 3 | Power output | 0.1~180V (AC) |
| 4 | Current output | 0.001~5A(RMS) |
| 5 | Power output | 300VA |
| 6 | Max. knee voltage measurement | 45kv |
| 7 | Current measurement range | 0~10A (automatically change range in 0.1/0.4/2/10A) |
| 8 | Current measurement error | <±0.1%+0.01%FS |
| 9 | Voltage measurement range | 0~200 V (automatically change range in 1V/10V/70V/200V) |
| 10 | Voltage measurement error | < ±0.1%+0.01%FS |
| 11 | Turns ratio measurement range | 1~35000; 1~2000 error<0.05%; 2000~5000 error>0.1%; 5000~35000 error<0.2% |
| 12 | Phase measurement | error:±2min,resolution:0.01min |
| 13 | Coil resistance measurement | Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm) Error< 0.2%RDG+0.02%FS Maximum resolution: 0.1mΩ |
| 14 | Temperature measurement | -50~100 Celsius degree, error<3 Celsius degree |
| 15 | CT Secondary burden | Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm) Error <0.2%RDG+0.02%FS Maximum resolution 0.001ohm |
| 16 | PT Secondary burden | Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm) Error <0.2%RDG+0.02%FS Maximum resolution: 0.1ohm |
| 17 | PT ratio measurement | Range: 1~35000, 1~5000 error<0.2% 5000~35000 error<0.5% |
| 18 | Saved data groups | >1000groups |
| 19 | Work condition | Temperature:-10℃-50℃, moist:≤90% |
| 20 | Size | 485mm×356mm×183mm |
| 21 | Weight | <15Kg |
Real Picture:
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Delta Technology (Chongqing) Co., Ltd.
Location
No.85 Zhong Shan Yi Road, Yu Zhong District, Chongqing, China. 400010
Contact Person
Tina Chen