Product Description
PEPPERL FUCHS Fieldbus Barrier R4D0-FB-IA12.0
| Product Description |
|---|
| Fieldbus barrier, module for DIN rail mounting |
| General specifications | ||
|---|---|---|
| Design / Mounting | Cabinet installation | |
| Installation in hazardous area | Zone 1 / Div. 2 | |
| Fieldbus connection | ||
| Power dissipation | see table 1 | |
| Main cable (Trunk) | ||
| Rated voltage | 16 ... 32 V DC , min. 15 V in case of brown out |
|
| Rated current | trunk IN to trunk OUT max. 2 A see table 1 | |
| Cable shield grounding option | Capacitive via 5.7 nF Direct |
|
| Voltage drop | trunk IN to trunk OUT 100 mV max. | |
| Number of couplers | max. 3 per segment | |
| Reverse polarity protection | Built-In | |
| Outputs | ||
| Number of outputs | 8, 10 or 12 | |
| Number of devices per output | 1 | |
| Cable length | 120 m | |
| Rated voltage | 10 ... 14 V | |
| Rated current | max. 43 mA at one spur , max. 320 mA total current at all spurs |
|
| Short-circuit current | 53 mA , 1 mA in fallback state | |
| Cable shield grounding option | Capacitive via 4.4 nF | |
| Surge protection | Trunk overvoltage protection if voltage exceeds typ. 39 V, max. 41 V | |
| Diagnostic and Protection Features | ||
| Fault Isolation | Short Circuit Current Limitation at spurs Bounce Protection at spurs Signal inhibit at spurs |
|
| Physical Layer Diagnostic | Signal level at spurs Signal jitter at spurs Noise level at spurs |
|
| Indicators/operating means | ||
| Switch | S1 ON: diagnostic alarms activated S2 ON: diagnostic warnings activated S3-S8: not used |
|
| LED PWR | green: Fieldbus voltage > 16 V | |
| LED COM/ERR | yellow flashing: fieldbus communication and physical layer status , red: Hardware error |
|
| LED SPURS | red: 2 Hz flashing in short-circuit condition | |
| Galvanic isolation | ||
| Main wire/outputs | isolation is not affected by interference according to EN 60079-11, voltage peak value 375 V | |
| Output/Output | No Isolation | |
| Directive conformity | ||
| Electromagnetic compatibility | ||
| Directive 2014/30/EU | EN 61326-1:2013 | |
| Standard conformity | ||
| Electromagnetic compatibility | NE 21:2011 | |
| Degree of protection | IEC/EN 60529 | |
| Fieldbus standard | IEC 61158-2 | |
| Climatic conditions | IEC 60721 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Ambient conditions | ||
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Relative humidity | < 95 % non-condensing | |
| Shock resistance | 15 g 11 ms | |
| Vibration resistance | 1 g , 10 ... 150 Hz | |
| Corrosion resistance | acc. to ISA-S71.04-1985, severity level G3 | |
| Mechanical specifications | ||
| Connection type | screw terminal , pluggable or spring terminal , pluggable | |
| Core cross section | see table 2 | |
| Housing material | Polycarbonate | |
| Degree of protection | IP20 | |
| Mass | 2100 g | |
| Dimensions | see dimensions | |
| Mounting | DIN rail mounting | |
| Data for application in connection with hazardous areas | ||
| EU-type examination certificate | BVS 13 ATEX E 121 X | |
| Marking | II 2(1)G Ex eb ib mb [ia Ga] IIC T4 Gb II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I |
|
| Main cable (Trunk) | ||
| Maximum safe voltage |
253 V AC | |
| Outputs | in accordance to FISCO and Entity | |
| Power | 1.063 W | |
| Voltage | 17.1 V | |
| Current | 248.55 mA | |
| Inductance | gas group IIC 470 µH , gas group IIB 2 mH |
|
| Capacitance | gas group IIC 367 nF , gas group IIB 2.15 µF |
|
| Directive conformity | ||
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN 60079-18:2015 | |
| International approvals | ||
| CSA approval | CSA 14.70004139 | |
| Control drawing | 116-0400 | |
| Approved for | Class I, Division 2, Groups A, B, C, D T4 Class I, Zone 1, AEx/Ex e ib mb [ia Ga] IIC T4 Gb Class I, Zone 1, AEx/Ex e ib mb [ia IIC Da] IIC T4 Gb Associated equipment for Class I, Division 1 Groups A, B, C, D Associated equipment for Class II, Division 1 Groups E, F, G Associated equipment for Class III, Division 1 |
|
| IECEx approval | IECEx BVS 13.0119X | |
| Approved for | Ex eb ib mb [ia Ga] IIC T4 Gb [Ex ia Da] IIIC [Ex ia Ma] I |
|
| Certificates and approvals | ||
| FOUNDATION Fieldbus | FF-846 | |
Are the Products Genuine OEM Units?
These items have been certified by Achievers Automation Limited to be genuine OEM Units obtained through OEM or independent third-party channels.
Does Achievers sell to international Non-USA customers?
Yes, Achievers offers services to clients around the globe. In fact, a large portion of our company is international, and we have experience shipping to locations all over the world.
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Achievers Automation Limited
Location
RM 509, 5/F, THE CLOUD, 111,TUNG CHAU STREET, TAI KOKTSUI, KOWLOON,HONG KONG
Contact Person
Caroline Chan
II 2(1)G Ex eb ib mb [ia Ga] IIC T4 Gb