YUEMI
                                                                                                           
Verified Supplier
24 Years
Since 2002
Menu

Medium Pressure Pump Lo-wara Mechanical Seal Replacement 22-X G9 I.T.T. LO-WARA

Price Negotiable
Price: US $ 48.8~52.8/PCS
MOQ: 1/PCS
Delivery Time: 2 word days
Brand: YUE MI
Product Description

 


 

 

 

 

G-14B Lowara pump seal 14mm
LWR-01-12mm and 16mm Lowara pump seal 12mm and 16mm
LWR-02-22mm Lowara pump seal 22mm

 

 

Product Description

YM® Seal Type. LOW  can be used in I.T.T. LOWARA® Pumps
e-SV Series Pump

Products Features
I.T.T. LOWARA® Pumps Types
YM® Seal Type LOW  can be used in I.T.T. LOWARA® Pumps
For more information, please do not hesitate to contact our Technology department
Combination Materials
1. Rotary Face
Reaction Bonded Sic RBSIC 
Sintered Silicon Carbide SSlC 
Tungten Carbide. Ni-binder 
2. Stationary Seat
Reaction Bonded Sic RBSIC 
Sintered Silicon Carbide SSlC 
Carbon graphite, resin impreg 
Carbon graphite,antimony impreg 
3. Auxiliary Seal
EPDM 
FKM 
NBR 
4. Spring
GrNi-Steel (AlS1304) 
GrNiMo-Steel (AlS13 16) 
5. Metal Parts
GrNi-Steel (AlS1304) 
GrNiMo-Steel (AlS13 16) 
 
 

 

 

Preperation:
1. Shaft Outside Diameter is within tolerance +-0.05mm
2. Shaft run out <0.1mm
3. Shaf end float <0.13mm
4, No sharp edges on the shaft over the o ring


Note:
During the installation,don't scratch or damage the o ring.lf anything is damaged,please contactwith Us to replace a new one.


Installation in strucstions:
1. The full set of cartridge seal is cleaned and exactly passed leakage examine before sale.Inorder to avoid damage,don't disassemble and clean the parts again before fixing.

 

2 The fitting allowance between the seal and shaft is dl h6 0.8,and there should be leading-inedge at the end of shaft.The outside diameter of shaft at the position of screw should be 01 0.2mm smaller,resisting the screw over-tighten.Lubricate the shaft with oil

 

3. Place the cartridge seal into the pump chamber,then:
A: Tighter four screw bolts of flanges,ensuring the medium leading in hole"G"at the top Position

B : Tighter four set screws and position the shaft sleeve on the shaft.
C: Remove four gauge plates.Please keep them and they wil be used in future installation and
disassemble.
D: Connect the medium lead_in pipe with hole"G"in order to flush away the friction heat and
flushing the seal chamber when pump running.


Note:
ter complete the installation,turning the shaft by hand to check for the rotationi he shat could not rotate smoothily,seal had been improperly installed.

 

 

 

We would like lo sincerely ooperale with Clients to supply high qually products and senice We beleve in establishing a long:erm cooperalive relalionshipis lhe key to suceess

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company YUEMI
Location Huadu District, Guangzhou City, Guangdong Province, China
Contact Person ZENG

Request A Quote

Please check your email address.
Your message must be at least 20 characters.