Technical Parameters

 

 

Temperature -30℃~+180℃
pressure ≤0.8Mp a
Speed ≤12m/s
Medium Chemical raw materials

 

Materials

 

Rotary Ring SIC CAR CE 
Stationary Ring

SIC CAR CE 

Spring SUS304/SUS316
Stationary Seat SUS304/SUS316
Secondary Seal

 Fkm/EPDM

Rotary Ring Holder SUS304/SUS316

 

Product Description

YM Seal Type CM can be used in Pumps
CM1, CM3, CM5, CM1O, CM15, CM25, CME1, CME3, CME5, CME10, CME15, CME25, CMV Series Pump, With shaft size 12mm and 16mm

Products Features
Pumps Types
YM  Seal Type CM can be used in Pumps
For more information, please do not hesitate to contact our Technology department
 
 

 

Preperation:
1. Shaft Outside Diameter is within tolerance +-0.05mm
2. Shaft run out <0.1mm
3. Shaf end float <0.13mm
4, No sharp edges on the shaft over the o ring


Note:
During the installation,don't scratch or damage the o ring.lf anything is damaged,please contactwith Us to replace a new one.


Installation in strucstions:
1. The full set of cartridge seal is cleaned and exactly passed leakage examine before sale.Inorder to avoid damage,don't disassemble and clean the parts again before fixing.

 

2 The fitting allowance between the seal and shaft is dl h6 0.8,and there should be leading-inedge at the end of shaft.The outside diameter of shaft at the position of screw should be 01 0.2mm smaller,resisting the screw over-tighten.Lubricate the shaft with oil

 

3. Place the cartridge seal into the pump chamber,then:
A: Tighter four screw bolts of flanges,ensuring the medium leading in hole"G"at the top Position

B : Tighter four set screws and position the shaft sleeve on the shaft.
C: Remove four gauge plates.Please keep them and they wil be used in future installation and
disassemble.
D: Connect the medium lead_in pipe with hole"G"in order to flush away the friction heat and
flushing the seal chamber when pump running.


Note:
ter complete the installation,turning the shaft by hand to check for the rotationi he shat could not rotate smoothily,seal had been improperly installed.

 

 

 

We would like lo sincerely ooperale with Clients to supply high qually products and senice We beleve in establishing a long:erm cooperalive relalionshipis lhe key to suceess

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company YUEMI
Location Huadu District, Guangzhou City, Guangdong Province, China
Contact Person ZENG

Request A Quote

Please check your email address.
Your message must be at least 20 characters.