YUEMI
                                                                                                           
Verified Supplier
24 Years
Since 2002
Menu

Syrup Rotor Pump Mechanical Seal 106-20mm 25mm 30mm 35mm 40mm

Price Negotiable
Price: US $ 28.8-38.8/PCS
MOQ: 1/PCS
Delivery Time: 2 word days
Brand: YUE MI
Product Description
Syrup Rotor Pump Mechanical Seal
Available in sizes: 106-20mm, 25mm, 30mm, 35mm, 40mm
Product Overview
Single Mechanical Seals designed for SRU (SSP SR) & NMOG Range. Double Mechanical Seal version available as W03DU.
Most commonly used on twin lobe pumps found extensively in Food Process, Dairy and Brewery Industries. Available in Food Grade materials as standard with FDA compliant materials.
Compatible Seal Alternatives
  • John Crane 87 (EI/EC) seal
  • Roplan RTH87/R90 seal
  • Sterling 280W/282 seal
Syrup Rotor Pump Mechanical Seal product image
INOXPA Pump Seal Specifications
Mechanical seal ROTATING PART15 SILICIO/EPDM 35
Part Numbers: 1G330-4050035, 4G15-47.35, -105078
Mechanical seal STATIONARY PART B15 GRAF/EPDM 35
Part Numbers: 1G322-1050035, 105081, 4GB151-7.35
Installation Preparation
  • Shaft Outside Diameter tolerance: ±0.05mm
  • Shaft run out: <0.1mm
  • Shaft end float: <0.13mm
  • No sharp edges on the shaft over the O-ring
Important Note: During installation, avoid scratching or damaging the O-ring. If any damage occurs, contact us immediately for replacement.
Installation Instructions
The full set of cartridge seal is cleaned and passed leakage examination before sale. To avoid damage, do not disassemble and clean parts again before installation.
Step 1: The fitting allowance between seal and shaft is dl h6 0.8. Ensure leading-in edge at shaft end. Outside diameter at screw position should be 0.1-0.2mm smaller to resist screw over-tightening. Lubricate shaft with oil.
Step 2: Place cartridge seal into pump chamber, then:
  • Tighten four screw bolts of flanges, ensuring medium leading in hole "G" at top position
  • Tighten four set screws and position shaft sleeve on shaft
  • Remove four gauge plates (keep for future installation and disassembly)
  • Connect medium lead-in pipe with hole "G" to flush away friction heat and flush seal chamber during pump operation
Verification: After complete installation, turn shaft by hand to check rotation. If shaft does not rotate smoothly, seal has been improperly installed.
Mechanical seal installation diagram
We sincerely cooperate with clients to supply high quality products and service. We believe establishing long-term cooperative relationships is key to success.
Mechanical seal technical specifications