Customized Slow EV Charging Station Auto Electronics Car Charger
Type 2 to Type 2 EV Cable Charger Type 2 to Type 2 EV Cable Charger detailed view
Product Specifications
SPECIFICATIONCABLE NAMEEV Cable
CABLE SPEC2C*80mm2+1C*25mm2+2C*4mm2+(3C*0.75mm2)(P2)+(7C*0.75mm2)
RoHS Compliant
Cable Construction Details
ItemA: 2C*80mm2B: 1C*25mm2C: 1C*4mm2D: (3C*0.75mm2)(P2)E: (7C*0.75mm2)
CONDUCTOR MaterialBared copper stranded
Size2580/0.20 ±0.008mm798/0.20 ±0.008mm224/0.15±0.008mm +10/1#Tinsel+1000D Kevlar40/0.15±0.008mm+ 10/0.19mmTinsel+200DKevlar40/0.15±0.008mm+ 10/0.19mmTinsel+200D Kevlar
O.D.(Ref.)12.40±0.25mm7.00±0.20mm2.70±0.15mm1.40±0.10mm1.40±0.10mm
INSULATION MaterialThermoplastic(EF2585,85±3A)
Min. average thickness1.60mm1.20mm1.00mm0.50mm0.50mm
Min.thickness at any point1.34mm0.98mm0.80mm0.35mm0.35mm
O.D.15.60±0.40mm9.60±0.30mm4.70±0.20mm2.50±0.10mm2.50±0.10mm
Additional Construction Features
CABLING-1Filler/CottonCotton
Material/AL-mylar(facing out)Non-woven
BRAID Material/Tinned copper/
Size/0.12mm,≥60%/
In-JACKET Material/TPETPE
Min. average thickness/0.60mm0.60mm
Min.thickness at any point/0.42mm0.42mm
O.D./7.20±0.25mm9.70±0.25mm
CABLINGFillerStrengthed PP rope
MaterialNon-woven(≥25% overlapping)
Assembly2C*80mm2+1C*25mm2+2C*4mm2+(3C*0.75mm2)(P2)+(7C*0.75mm2)
JACKET MaterialTPU
Min. average thickness2.80mm
Min.thickness at any point2.28mm
O.D.38.00+0.6/-1.00mm
Performance Characteristics
ELECTRICAL CHARACTERISTICSPHYSICAL PROPERTIES
Rated voltage: DC 1000VTensile strength: ≥20MPa
Rated temperature: Jacket -40~90ºC
Insulation -40~125ºC
Elongation: ≥300%
Max. conductor resistance(20ºC):
A:0.242Ω/km B:0.78Ω/km
C:4.95Ω/km D&E:26Ω/km
Aged condition: 110±1ºC*168h
Insulation Voltage withstand(Core A &B,10m):
AC 2.5kV/5min,leakage current ≤5mA
Percent of original tensile strength: ≤±30%
Completed cable Voltage withstand(Core A to A &B,10m):
AC 3.5kV/15min,leakage current ≤5mA
Percent of original elongation: ≤±30%
Min. Insulation resistance(20ºC, Core A to A &B):500MΩ.kmFlame test: GB/T 18380.12-2008
Artificial weathering test: GB/T 33594
Low-temperature impact test: -40ºC*16H,No crack
Chemical stress acid: N-Oxal-acid alkaline solution, N-sodium hydroxide solution:GB/T 33594
Vehicle rolling: Requirements and test methods should be consistent with GB/T 20234.1-2015 7.21
Additional Test Standards
High temperature pressure test: ≤50%
Heat shock test: No crack
Compatibility test: GB/T 33594
Crush resistance test: GB/T 33594
Curved around the test: GB/T 33594
Min. Bend radius: 6*OD
Abrasion resistance: ≥2000times
Resistance against chemicals: GB/T 33594
Cable Structure Specifications
NO.conductor mm2insulution20ºC conductor resistance (Ω/KM)
conductor mm2Structure(N/mm)Conductor DIA(mm)ConductorThickness (mm)MATERIALinsulution OD (mm)
EV-YJ1.548/0.201.60copper0.6silicone2.90±0.15≤12.7
EV-YJ2.580/0.202.06copper0.7silicone3.50±0.15≤7.60
EV-YJ4128/0.202.62copper0.8silicone4.30±0.15≤4.71
EV-YJ6196/0.203.50copper0.8silicone5.10±0.20≤3.14
EV-YJ10322/0.204.50copper1.00silicone6.70±0.20≤1.82
EV-YJ16513/0.205.70copper1.10silicone8.00±0.30≤1.16
EV-YJ25798/0.207.10copper1.3silicone9.80±0.30≤0.743
EV-YJ351121/0.208.50copper1.3silicone11.40±0.30≤0.527
EV-YJ501596/0.2010.10copper1.50silicone13.50±0.30≤0.368
EV-YJ702242/0.2012.10copper1.50silicone15.50±0.40≤0.259
EV-YJ953034/0.2014.10copper1.50silicone17.50±0.50≤0.196
Product Features
EV Cable construction details
Conductor: Flexible Bare annealed copper wire
Insulation: Silicone
Color Options: Choice of Black, Orange, Red or Yellow Blue jacket, single & double insulated
SQ MM sizes (European style): 4 sq mm to 240 sq mm
AWG sizes (North American style): 0AWG-10AWG
Wide temperature range: -60°C to 200°C
Low viscosity appearance
EV Cable cross-section EV Cable application EV Cable manufacturing EV Cable quality control EV Cable certifications
Quality Certifications
• UL1007, UL1185, UL1672, UL10070, UL10483, UL1015, UL1569, UL10012, UL10269 (Single conductor, thermoplastic insulation)
• UL2095, UL2129, UL2468, UL2586, UL2725, UL20233, UL20280, UL20963, UL2103, UL2464, UL2576, UL2661, UL2919, UL20279, UL20886, UL21664
• ISO9001 and ISO13485, TS16949
• CNR- Appliance Wiring Material
• Extruded PVC Insulated Single, rated 105ºC, 1000V, Class I, Group A, B, or AB, FT1 and/or FT2
• Extruded PVC Non-integral Jacketed Cable, rated 105ºC, 1000V, Class I, Class or Class I/II, Group A, B, or AB, FT1 and/or FT2
• Extruded TPU Non-integral Jacketed Cable, rated 80ºC, 300V, Class I, Class or Class I/II, Group A, B, or AB, FT1 and/or FT2
Frequently Asked Questions
1. Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first beginning to the last. Welcome to visit us. We'll pick you up in Shenzhen.
2. How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.
3. What's your Minimum Order Quantity?
Normally 100m. However, the cable is very heavy. You'd better order a suitable quantity to avoid the high freight. Sea transportation is the best option.
4. Can I get a discount?
It depends on your quantity. We can make a discount and afford the freight. Please kindly contact us.
5. Does your company accept OEM production?
Yes, we can print your company name, and we even custom the quality card to promote your company.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Linke Cable Technology (DongGuan) CO.,LTD
Location No. 1, Yiheng Road, Qinghu Private Park, Qishi Town, Dongguan City, Guangdong Province
Contact Person William Liu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.