Linke Cable Technology (DongGuan) CO.,LTD
                                                                                                           
Verified Supplier
22 Years
Since 2004
Menu

3034/0.20 Structure Multi Core Flexible Power Cable Electric Wire for Easy Maintenance

Price Negotiable
Price: Negotiable
MOQ: 1000m
Delivery Time: 7-15 days
Brand: Linke
Product Description

5core 7core 9core OEM Automotive Trailer Truck Cable
 

2 3 4 5core Multi Core Instruction Flexible Power Cable Electric Wire

 
 

Structural parameter table:

Category

Wire specifications

Reference current

(A)

Diameter

(mm)

UL:EVE,EVT

600V

3×16AWG 12 10.8
3×14AWG 16 13.4
3×12AWG 23 14.2
3×10AWG 32 16.2
3×16AWG+1×18AWG 12 11.4
3×14AWG+1×18AWG 16 13.6
3×12AWG+1×18AWG 23 14.3
3×10AWG+1×18AWG 32 15.9
3×8AWG+1×18AWG 46 21.8
2×8AWG+10AWG+18AWG 46 20.9
2×6AWG+8AWG+18AWG 63 23.1
2×4AWG+6AWG+18AWG 75 26.5
2×2AWG+4AWG+18AWG 100 30.1
3×16AWG+2×18AWG 12 12.1
3×14AWG+2×18AWG 16 13.9
3×12AWG+2×18AWG 23 15.0
3×10AWG+2×18AWG 32 16.6
2×8AWG+10AWG+2×18AWG 46 21.9
2×6AWG+8AWG+2×18AWG 63 24.8

UL:EVJE,EVJT

300V

3×16AWG 12 8.2
3×14AWG 16 9.0
3×12AWG 23 10.1
3×16AWG+1×18AWG 12 8.8
3×14AWG+1×18AWG 16 9.5
3×12AWG+1×18AWG 23 11.2
3×16AWG+2×18AWG 12 9.5
3×14AWG+2×18AWG 16 12.1
3×12AWG+2×18AWG 23 13.2

2 3 4 5core Multi Core Instruction Flexible Power Cable Electric Wire

ELECTRICAL CHARACTERISTICS PHYSICAL PROPERTIES
Rated voltage:DC 1000V Tensile strength:≥20MPa High temperature pressure test:≤50%      
Rated temperature:Jacket  -40~90ºC Elongation:≥300% Heat shock test:No  crack                       
                                 Insulation  -40~125ºC Aged condition:110±1ºC×168h Compatibility test:GB/T 33594
Max. conductor resistance(20ºC): Percent of original tensile strength:≤±30% Crush resistance test:GB/T 33594
A:0.242Ω/km  B:0.78Ω/km  C:4.95Ω/km   D&E:26Ω/km Percent of original elongation:≤±30% Curved around the test:GB/T 33594
Insulation  Voltage withstand(Core A&B,10m): Flame  test:GB/T 18380.12-2008 Min.  Bend  radius:6*OD
AC 2.5kV/5min,leakage current ≤5mA Artificial weathering test:GB/T 33594 Abrasion resistance:≥2000times
Completed cable  Voltage withstand(Core A  to A&B,10m): Low-temperature impact test :-40ºC×16H,No  crack Resistance against chemicals:GB/T 33594
AC 3.5kV/15min,leakage current ≤5mA Chemical stress acidN-Oxal-acid alkaline solution, N-sodium hydroxide solution:GB/T 33594
Min. Insulation resistance(20ºC, Core A  to  A&B):500MΩ.km Vehicle rolling:Requirements and test methods should be consistent with GB/T 20234.1-2015 7.21
 
 
2 3 4 5core Multi Core Instruction Flexible Power Cable Electric Wire
Conductor : Flexible Bare annealed copper wire 
Insulation:Silicone
Choice of Black, Orange, Red or Yellow Blue jacket, single & double insulated.
SQ MM sizes (European style) :4 sq mm to 240 sq mm
AWG sizes (North American style) :0AWG-10AWG,
Wide temperature range: -60°C to 200°C 
 
 
2,Low viscosity appearance
2 3 4 5core Multi Core Instruction Flexible Power Cable Electric Wire
Conductor : Flexible Bare annealed copper wire 
Insulation:Silicone
Choice of Black, Orange, Red or Yellow Blue jacket, single & double insulated.
SQ MM sizes (European style) :4 sq mm to 240 sq mm
AWG sizes (North American style) :0AWG-10AWG,
Wide temperature range: -60°C to 200°C 
2 3 4 5core Multi Core Instruction Flexible Power Cable Electric Wire2 3 4 5core Multi Core Instruction Flexible Power Cable Electric Wire2 3 4 5core Multi Core Instruction Flexible Power Cable Electric Wire2 3 4 5core Multi Core Instruction Flexible Power Cable Electric Wire2 3 4 5core Multi Core Instruction Flexible Power Cable Electric Wire
Company Profile:

Wire and cable manufacturer Linke Cable Technology Co., Ltd is a leading cable supplier in China. In the past over 10 years,

Linke Cable has been focusing on R&D, production and marketing of wire and cable. Linke provide various cables&custom

cable solutions for all over the world. We are specialized in EV charging cable, medical cable, silicone cable, spring cable,

braided cable, towlobe cable, UL wire, automotive cable, etc.

At Linke cable, we believe there's a better way to bring better cables to market. We use an engineer-to-engineer approach

to develop better cables for customers and  improve the quality of one's life.
 

Our certification:

We past UL1007,UL1185,UL1672,UL10070,UL10483,UL1015,UL1569,UL10012,UL10269

(Single conductor,thermoplastic insulation)
UL2095,UL2129,UL2468,UL2586,UL2725,UL20233,UL20280,UL20963,UL2103,UL2463,UL2517,UL2587,UL2835,

UL20276,UL20549,UL21198,2104,UL2464,UL2576,UL2661,UL2919,UL20279,UL20886,UL21664

ISO9001 and ISO13485,TS16949

CNR- Appliance Wiring Material,

Extruded PVC Insulated Single,rated 105ºC,1000V,ClassI,GroupA,B,or AB, FT1 and/or FT2.

Extruded PVC Non-integral Jacketed Cable, rated 105"C, 1000V, Class I, Class or Class I/Il, Group A, B, or AB, FT1 and/or FT2.

Extruded TPU Non-integral Jacketed Cable, rated 80"C, 300V, Class I, Class or Class I/Il, Group A, B, or AB, FT1 and/or FT2

FAQ

1. Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first begining to the last. 

Welcome to visit us. We'll pick you up in Shenzhen.
 

2. How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.

 

3. What's your Minimum Order Quantity?
Normally 100m. However, the cable is very heavy. 
You'd better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.

 

4. Can I get a discount?
It depends on your quantity, We can make a discount and afford the freight. Pls kindly contact us.

 

5. Does your company accept OEM production?
Yes, could print your company name, we even custom the quality card to promote your company

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Linke Cable Technology (DongGuan) CO.,LTD
Location No. 1, Yiheng Road, Qinghu Private Park, Qishi Town, Dongguan City, Guangdong Province
Contact Person William Liu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.