Heat-Resistant UL1007 PVC Insulated Wire 16-28 AWG Tinned Copper Cable with Wide Temperature Range
Heat-Resistant UL1007 Electric PVC Insulated Wire
Linke cable technology (DongGuan) Co. Ltd. concentrate on R&D and provide professional solutions to the Cable&Wire,especially for the different industry customers.It contains :
- Humanoid robot cable
- AI power cable/data cable
- Semiconductor cable/industrial automatic cable
- Sensor cable
- New energy cable
- Medical beauty wire
- UL wire cable
Linke Cable has diversified product development capabilities and technical capabilities to support diversified customer needs. We have obtained the following product authorization:UL 758,CCC,RoHs,REACH,CE; We have obtained the following quality management system:ISO 9001-2015(All products); ISO 13485(Medical apparatus and instruments),IATF 16949(Auto industry)
Independent Laboratory • Complete Testing Equipment • Full Quality Control
We test every product by strict standards to ensure superior quality and reliable performance.
We operate an independent quality testing laboratory with complete testing facilities and standardized procedures. Our full set of product testing standards covers all key performance and safety indicators. Through systematic and rigorous inspection, we effectively control product quality, reduce risks, and provide you with safe, stable and high-quality products you can trust.
| No. | Test Item | Test Condition | Test Requirement | Test Data | Result |
|---|---|---|---|---|---|
| 1 | Structure Inspection | 1. Comply with wire size table 2. Minimum thickness ≥ 80% of average thickness |
Comply with wire size table | Refer to test record | Pass |
| 2 | Thermal Shock | Wind the sample on an iron rod of specified size, place in an aging oven at specified temperature for 1 hour, cool the sample to room temperature for at least 30 minutes, then observe the sample | No cracks on the sample surface | No cracks | Pass |
| 3 | Heat Deformation | 1. Measure sample thickness (mark measurement position) 2. Place sample and test fixture in aging oven for preheating at specified temperature for 1 hour 3. Place sample under pressure column of test fixture for 1 hour 4. Re-measure sample thickness at the same position |
1. Sample shall not be cracked by pressure column or expose conductor 2. Thickness reduction ≤ 50% |
Refer to test record | Pass |
| 4 | FT2 | Apply a standard flame at a height of 125mm once | 1. Flame shall not propagate along its length 2. Flame shall not spread to nearby flammable materials |
Refer to test record | Pass |
| 5 | Aging | 1. Take five sections of 200mm-long sheath 2. Place specimens in aging oven at 158℃ for 168 hours 3. After taking out specimens, place at room temperature 23±5℃ for 16 hours, then test elongation at break and tensile strength |
1. Elongation before aging ≥ 300%, elongation after aging ≥ 80% of that before aging 2. Tensile strength before aging > 1.41kg/mm², tensile strength after aging ≥ 80% of that before aging |
Refer to test record | Pass |
| 6 | Cold Bend | Store sample in low-temperature box at specified temperature for 4 hours, wind sample on iron rod of specified size with specified turns, complete winding within 30 seconds after sample is taken out of low-temperature box | No cracks on the sample surface | No cracks | Pass |
| 7 | Conductor Resistance | Measure resistance of one-meter core conductor with DC resistance meter | At 20℃, resistance of 8AWG ≤ 2.23Ω/km | Refer to test record | Pass |
Product Specifications
- Conductor: Flexible Bare Annealed Copper Wire
- Insulation Options: PVC, TPU, XLPE, Silicone
- Jacket Colors: Black, Orange, Red, Yellow, Blue (single & double insulated)
- European Sizes (SQ MM): 0.1-100SQ
- North American Sizes (AWG): 0AWG-10AWG
- Temperature Range: -60°C to 200°C
Certifications & Standards
Our cables meet rigorous international standards including:
UL Certifications
Single Conductor, Thermoplastic Insulation:
| 1007 | 1330 | 1333 | 1591 | 1723 | 10064 | 10369 |
| 1015 | 1331 | 1569 | 1592 | 1901 | 10070 | 10483 |
| 1185 | 1332 | 1577 | 1672 | 10012 | 10269 |
Multiple Conductor, Thermoplastic Insulation:
| 2095 | 2129 | 2468 | 2586 | 2725 | 20233 | 20280 | 20963 |
| 2103 | 2463 | 2517 | 2587 | 2835 | 20276 | 20549 | 21198 |
| 2104 | 2464 | 2576 | 2661 | 2919 | 20279 | 20886 | 21664 |
Single Conductor, Thermoset Insulation:
| 3075 | 3173 | 3320 | 3386 | 3530 | 3689 | 30005 | |
| 3123 | 3212 | 3321 | 3398 | 3577 | 3702 | ||
| 3132 | 3266 | 3331 | 3512 | 3644 | 3817 | ||
| 3135 | 3271 | 3385 | 3529 | 3674 | 3886 |
Additional Certifications: ISO9001, ISO13485, TS16949, CNR Appliance Wiring Material
Our cables are rated for various applications including extruded PVC insulated single conductor (rated 105°C, 1000V), extruded PVC non-integral jacketed cable (rated 105°C, 1000V), and extruded TPU non-integral jacketed cable (rated 80°C, 300V).
Frequently Asked Questions
Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first beginning to the last. Welcome to visit us. We'll pick you up in Shenzhen.
How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.
What's your Minimum Order Quantity?
Normally 100m. However, the cable is very heavy. You'd better order a suitable quantity to avoid the high freight. Sea transportation is the best option.
Can I get a discount?
It depends on your quantity. We can make a discount and afford the freight. Please kindly contact us.
Does your company accept OEM production?
Yes, we can print your company name and even customize the quality card to promote your company.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.