WEYO AUTO TECH
                                                                                                           
Verified Supplier
23 Years
Since 2003
Menu

HPAS High-Pressure Single-Seat Angle Valve

Price Negotiable
Price: Based on oroiect reauirements
MOQ: Negotiable
Delivery Time: 7 - 15 days for small orders, 15 - 30 days for large orders
Brand: WEYO
Product Description
HPAS high-pressure single-seat angle valve is a top-guided control valve, featuring small pressure drop loss in the valve body, large flow rate and wide adjustable range. The angle valve can be selected according to the requirements of pipeline turning layout.

 

The valve core has a large guiding area and good vibration resistance. The control valve is equipped with a multi-spring diaphragm actuator, which has a compact structure and large output force. The angle valve can be widely used to control high-pressure fluids at various temperatures.
 
Cv value and stroke are shown in Table 1.
Nominal diameter (mm) 25 40 50 80
Valve seat diameter (mm)   25 32 40 32 40 50 50 65 80
Rated Cv value Equal percentage linearity JIS63K
ANSI9001500
0.25 0.4 0.63 1 1.6 2.5 4 6.3 12 12 17 25 17 25 47 47 75 110
ANSI2500 - 12 17 12 17 31 31 47 75
Rated stroke (mm) 14.3 25 38

 

Allowable pressure difference

I. Valves equipped with HA and VA actuators (with positioners) are shown in Tables 2 and 3.

A. Air-closed valves (Table 2)
Nominal pressure Actuator Supply pressure
(MPa)
Spring range
(MPa)
Allowable pressure difference
Valve seat diameter (mm) or Cv value
Cv≤4.0 Cv=6.3 Cv=12 32 40 50 65 80
ANSI
900
1500
JIS
63K
HA3D 0.28 0.04~0.20 16.3
15.2
16.1
14.9
10.2
9.2
5
4.2
3.2
2.7
1.8
1.4
1
0.70
0.70
0.40
0.3 20.7
19.6
20.5
19.2
13
12
6.4
5.7
4.2
3.6
2.4
1.9
1.4
1
0.90
0.60
0.35 26.4 26.4 20
19
10
9.2
6.6
6
3.8
3.4
2.3
1.9
1.6
1.3
0.4 - - 26.4
26
13.5
12.8
9.1
8.5
5.3
4.8
3.2
2.8
2.2
1.9
HA4D 0.28 - - 18.3
17.3
9.1
8.4
6.1
5.5
3.5
3
2.1
1.7
1.4
1.1
0.3 - - 23.1
22.1
11.6
10.9
7.7
7.1
4.5
4
2.7
2.3
1.9
1.6
0.35 - - 26.4 17.7
17
11.9
11.3
7
6.5
4.2
3.9
3
2.7
0.4 - - - 23.9
23.2
16.1
15.5
9.5
9
5.8
5.4
4.1
3.8
VA5D 0.26 0.02~0.10 - - - 26.3
25.5
17.7
17.1
10.4
10
6.3
6
4.5
4.2
0.28 - - - 26.4 20
19.4
11.8
11.4
7.2
6.8
5.1
4.8
ANSI
2500
HA3D 0.28 0.04~0.20 16.3
15.2
16.1
14.9
10.2
9.2
10.2
9.2
5
4.2
2.5
2
1.8
1.4
1
0.70
0.3 20.7
19.6
20.5
19.2
13
12
13
12
6.4
5.7
3.3
2.8
2.4
1.9
1.4
1
0.35 31.6
30.5
31.4
30.1
20
19
20
19
10
9.2
5.2
4.7
3.8
3.4
2.3
1.9
0.4 42.5
41.4
42.3
41
27
26
27
26
13.5
12.8
7.2
6.7
5.3
4.8
3.2
2.8
HA4D 0.28 - - 18.3
17.3
18.3
17.3
9.1
8.4
4.8
4.3
3.5
3
2.1
1.7
0.3 - - 23.1
22.1
23.1
22.1
11.6
10.9
6.1
5.6
4.5
4
2.7
2.3
0.35 - - 35.1
34.1
35.1
34.1
17.7
17
9.5
8.9
7
6.5
4.2
3.9
0.4 - - 44 44 23.9
23.2
12.8
12.3
9.5
9
5.8
5.4
VA5D 0.26 0.02~0.10 - - - - 26.3
25.5
14.1
13.6
10.4
10
6.3
6
0.28 - - - - 29.6
28.9
15.9
15.4
11.8
11.4
7.2
6.8
Remarks:
  1. The maximum allowable pressure difference shall not exceed the maximum value specified in the ANSI B16.34 standard.
  2. The maximum allowable pressure difference varies with the valve seat leakage. The pressure difference given in the upper part of the same cell indicates the condition when the valve seat leakage is ≤0.01%, while the pressure difference in the lower part indicates the condition when the valve seat leakage is ≤0.001%.
  3. The inlet pressure P1 shall not exceed the maximum allowable pressure difference when the valve is closed.

 

B. Air-to-open valves Table 3
Nominal pressure Actuator Supply pressure
(MPa)
Spring range
(MPa)
Allowable pressure difference (MPa)
Valve seat diameter (mm) or Cv value
Cv≤4.0 Cv=6.3 Cv=12 32 40 50 65 80
ANSI
900
1500
HA3R 0.26~0.04
(*4)
0.08~0.24 16.3
15.2
16.1
14.9
10.2
9.2
5
4.2
3.2
2.7
1.8
1.4
1
0.70
0.70
0.40
HA4R 18.7
18
18.5
17.7
18.3
17.3
9.1
8.4
6.1
5.5
3.5
3
2.1
1.7
1.4
1.1
VA5R - - - 12.7
12
8.5
7.9
5
4.5
3
2.6
2.1
1.8
VA6R 0.30(*1) 0.19~0.25 26.4 26.4 26.4 25.8 17.4 10.2 6.2 4.4
0.35(*2) 0.19~0.30
0.40(*3) 0.19~0.35 26.4 26.4 26.4 25.1 16.8 9.8 5.9 4.1
ANSI
2500
HA3R 0.26~0.40
(*4)
0.08~0.24 16.3
15.2
16.1
14.9
10.2
9.2
10.2
9.2
5
4.2
2.5
2
1.8
1.4
1
0.70
HA4R 18.7
18
18.5
17.7
18.3
17.3
18.3
17.3
9.1
8.4
4.8
4.3
3.5
3
2.1
1.7
VA5R 0.26~0.28
(*4)
- - - - 12.7
12
6.8
6.2
5
4.5
3
2.6
VA6R 0.30(*1) 0.19~0.25 32.9 32.8 32.7 32.7 25.8 13.8 10.2 6.2
0.35(*2) 0.19~0.30
0.40(*3) 0.19~0.35 32.5 32.3 32 32 25.1 13.3 7.8 5.9

 

II. Valves equipped with VP actuators (with positioners) are shown in Tables 4
公称压
执行
机构
供气
压力
(MPa)
允许压差(MP)
阀座直径(mm)或Cv值
Cv≤4.0 Cv=6.3 Cv=12 32 40 50 65 80
ANSI
900
1500
VP5 0.3 18.8
18.5
18.7
18.4
18.6
18.2
18.4
17.7
14.2
13.6
8.3
7.9
5
4.7
3.6
3.3
0.4 25.1
24.8
25.1
24.7
25
24.5
24.7
24.1
19.1
18.5
11.3
10.8
6.9
6.5
4.9
4.6
0.5 26.4 26.4 26.4 26.4 24
23.4
14.2
13.8
8.7
8.3
6.2
5.9
VP6 0.3 - - - - 17.9
17.5
14.6
14.2
8.9
8.6
6.4
6.1
0.4 - - - - 24
23.6
19.7
19.2
12.1
11.7
8.6
8.3
0.5 - - - - 26.4 24.8
24.3
15.2
14.8
10.9
10.6
VP7 0.3 - - - - - 17.5
17.1
13.8
13.5
9.9
9.6
0.4 - - - - - 23.4
23.1
18.6
18.2
13.3
13
0.5 - - - - - 26.4 23.3
22.9
16.7
16.4
ANSI
2500
VP5 0.3 18.8
18.5
18.7
18.4
18.6
18.2
18.6
18.2
18.4
17.7
11.3
10.7
8.3
7.9
5
4.7
0.4 25.1
24.8
25.1
24.7
25
24.5
25
24.5
24.7
24.1
15.2
14.7
11.3
10.8
6.9
6.5
0.5 31.5
32.2
31.4
31.1
31.3
30.9
31.3
30.9
31
30.4
19.2
18.6
14.2
13.8
8.7
8.3
VP6 0.3 - - - - - 17.8
17.3
14.6
14.2
8.9
8.6
0.4 - - - - - 23.9
23.5
19.7
19.2
12.1
11.7
0.5 - - - - - 30
29.6
24.8
24.3
15.2
14.8
VP7 0.3 - - - - - - 17.5
17.1
13.8
13.5
0.4 - - - - - - 23.4
23.1
18.6
18.2
0.5 - - - - - - 29.4
29
23.3
22.9
Remarks:
  1. If the actuator is equipped with an auxiliary air supply, the smaller one of the two supply pressures shall be selected as the basis for calculating the allowable pressure difference.
  2. The maximum allowable pressure difference shall not exceed the maximum value specified in the ANSI B16.34 or JIS B2201 standard.
  3. The inlet pressure P1 shall not exceed the allowable pressure difference when the valve is closed.
  4. The maximum allowable pressure difference varies with the valve seat leakage. The pressure difference given in the upper part of the same cell indicates the condition when the valve seat leakage is ≤0.01%, while the pressure difference in the lower part indicates the condition when the valve seat leakage is ≤0.001%.

 

Flange distance is shown in Table 5.
Table 5 Unit: mm
Nominal diameter A
JIS63KRF ANSI900 ANSI1500 ANSI2500
RF,SW,BW RJ RF,SW,BW RJ RF,SW,BW RJ
25 138 146 159 159
40 161.5 166.5 179 180.5
50 177 187.5 189 188 189 225 225
80 215.5 220 220 230 230 270 270

 

Equipped with HA,VA5,VA6,VP actuator

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company WEYO AUTO TECH
Location Room Milton103, Building 5 - 2, Lane 658, Jinzhong Road, Changning District, Shanghai.
Contact Person flnn

Request A Quote

Please check your email address.
Your message must be at least 20 characters.