1000L Climate Chamber CMS-1000A with lighting
1000L Climate Chamber CMS-1000A with lighting
Features:
- Utilizes a PID temperature control system supporting programmable operation modes.
- Features a large LCD touch screen that displays all operating parameters in real-time.
- Dual air circulation system combining forced convection with vertical diffusion.
- High-quality antibacterial stainless steel chamber with rounded corners for easy cleaning.
- Three-sided lighting system with 5 adjustable intensity levels, accurately simulating natural day-night cycles.
- Independent drainage pipes prevent chamber debris from contaminating the humidification water source.
- Automatic defrosting function prevents temperature and humidity drift caused by evaporator frosting.
- Detachable protective cover for temperature and humidity sensors prevents failure from poor contact.
- Equipped with universal dual-wheel casters with brakes for safe and convenient mobility.
- Unique air duct structure resistant to high and low temperatures, paired with a specialized fan.
- External RS485 communication interface enables remote PC control and monitoring.
- Comprehensive safety protections: leakage protection, independently adjustable temperature safety device.
- Water shortage/overflow protection, compressor overvoltage protection, cooling fan overheating protection.
- Triple alarm system for door opening, power failure, and sensor failure.
- Core components include German compressors and Swiss Rotronic humidity sensors.
- Optional infrared CO2 concentration monitoring and control system.
Specifications
| Model | CMS-300A | CMS-450A | CMS-800A | CMS-1000A |
| CMS-300B | CMS-450B | CMS-800B | CMS-1000B | |
| Convection Mode | Forced convection | |||
| Control Mode | Balance | |||
| Temperature Resolution | 0.1℃ | |||
| Temperature Control Range | With illumination: 10℃~65℃ Without illumination: 0℃~65℃/±0.1℃ | |||
| Humidity Control Range | <20~95%RH/±1.5%RH | |||
| Illumination | 0~25000LX,5-grade adjustment(Optional: 0-30000LX) | |||
| Working Temperature | 5℃~30℃ | |||
| Programme Control | Programmable LCD with touch screen | |||
| Overall Dimensions(W*D*H,mm) | 800*910*1610 | 790*990*1860 | 1200*1100*1900 | 1540*1100*1900 |
| Chamber Dimensions(W*D*H,mm) | 600*565*900 | 605*650*1150 | 1020*700*1150 | 1280*700*1150 |
| Volume | 305L | 452L | 822L | 1030L |
| Refrigerant | R134a | |||
| Rated Power | 2200W | 2450WV | 3100W | 3500W |
| Water Tank Capacity | 20L | |||
| Power Supply | AC-220V,50/60HZ | |||
| Safety Protection | Compressor over pressure protection, over heat protection,current leakage progection, over load, under pressure, water shortage protction | |||
| Shelf Qty. | 3 | |||
| Notes: Humidity control,water tank and water pipes are not available for CMS-300A/450A/800A/100A | ||||
Introduction about incubator
The reliability of any scientific instrument hinges on rigorous calibration and maintenance, and laboratory incubators are paramount in this regard. Given their role in sustaining sensitive biological processes, even minor deviations in temperature, humidity, or CO2 can compromise months of research. Regular calibration against NIST-traceable standards is non-optional. Temperature uniformity mapping, often performed annually, ensures every shelf location within the chamber meets the setpoint, critical for multi-rack experiments. CO2 sensors, whether thermal conductivity (TC) or infrared (IR), require routine calibration with certified gas mixtures; IR sensors generally offer greater stability and resistance to humidity fluctuations. Humidity control, often managed via a passive water pan or active steam generator, needs monitoring to prevent under-humidification (causing media desiccation) or over-humidification (risking condensation and contamination).
Preventive maintenance includes cleaning and decontamination protocols, often using hydrogen peroxide vapor or specialized disinfectants, coupled with replacing HEPA filters to ensure clean airflow. Modern units feature data logging and alarm systems that document conditions and alert researchers to deviations, a feature essential for Good Laboratory Practice (GLP) and regulatory compliance in pharmaceutical or clinical work. Thus, a well-maintained incubator is not just a box that provides heat; it is a validated, traceable component of the research infrastructure, directly safeguarding data integrity and reproducibility.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.