Single Beam UV Visible Spectrophotometer UA-300C 
with 2nm Bandwidth and 190-1100nm Wavelength
Advanced Intelligent Architecture
  • High-Speed Processing: Integrated with a high-performance ARM chip to ensure rapid data computation.
  • Graphical Interface: Features a 128x64 dot-matrix backlit LCD for crystal-clear visual data presentation.
  • Seamless Data Transfer: Equipped with a USB port for the convenient export of analytical results.
  • Simplified Updates: Supports instant, one-click system firmware upgrades.
  • Flexible Calibration: Allows users to input customized wavelength correction parameters for enhanced precision.
  • Autonomous Alignment: Features self-acting wavelength calibration, removing the necessity for manual intervention.
  • Lamp Life Tracking: Automatically records cumulative light source usage to streamline maintenance scheduling.
  • Eco-Friendly Management: The light source menu allows users to deactivate unused lamps, significantly prolonging their operational life.
Comprehensive Functional Menu
  • Versatile Testing Suites: Pre-loaded with applications for photometric testing, standard curve quantification, spectral scanning, kinetics, DNA/Protein analysis, GLP validation, and multi-wavelength assays.
Optimized Data Management
  • Robust Onboard Storage: Capable of archiving up to 1,000 distinct data entries locally.
  • Versatile Printing Options: Supports integration with either internal or external micro-printers for hard-copy output.
  • Desktop Synchronization: Facilitates PC connectivity for sophisticated data interpretation and post-experimental analysis.
Photometric Analysis
  • Wide-Spectrum Detection: Measures transmittance or absorbance across the 190-1100nm range using flexible single-point testing protocols.
  • Direct Concentration Readout: Determines sample density instantly by configuring standard concentrations or specific slope factors.
Quantitative Analysis
  • Advanced Curve Modeling: Calculates unknown concentrations via pre-set parameters or by generating automated standard curves.
  • Mathematical Fitting: Provides linear, zero-intercept, quadratic, and cubic curve fitting, alongside dual-wavelength and three-point correction methods.
  • Curve Memory: Allows for the long-term storage and rapid retrieval of calibrated standard curves.
Spectrum Scanning
  • High-Resolution Scans: Enables interval-based measurements of absorbance, energy, or reflectance for both solids and liquids across up to 100 data points.
  • Automated Peak Analysis: Identifies peaks and valleys automatically, with full support for saving and printing historical spectral graphs.
Kinetic Time Scanning
  • Reaction Monitoring: Tracks absorbance or transmittance fluctuations over a defined duration at specific wavelengths to study reaction dynamics.
  • Rate Computation: Converts raw absorbance data into reaction rates or concentration values using customizable input factors.
Multi-Wavelength Mode
  • Concurrent Testing: Permits the simultaneous configuration of 10 wavelength coordinates for rapid sample solution screening.
DNA/Protein Quantification
  • Biomolecular Assessment: Evaluates DNA/Protein ratios and concentrations by measuring specific absorbance peaks at 260nm, 280nm, 230nm, and 320nm.
GLP Instrument Verification
  • Compliance & Validation: Audits wavelength precision, photometric accuracy, and stray light levels, producing verifiable results for storage, export or printing.
Additional Functions

Accumulated operating time for deuterium and tungsten lamps, independent on/off control for deuterium and tungsten lamps, switching between UV and visible light wavelength points, and automatic wavelength calibration.

Packing list
  • Spectrophotometer x1
  • 10-50mm 4-position adjustable holder x1
  • dust cover x1
  • 1cm quartz cuvette x2
Multiple Optional Accessories
  • 8-position automatic sample rack
  • Single-slot microsample rack (minimum measurable 50u samples)
  • 5-10 cm sample racks (suitable for water quality testing)
  • Single-slot or three-slot water bath colorimetric dish rack (suitable for temperature-controlled sample requirements)
  • PC control software for extended functionality
  • Printer
Specifications
Mode UA-300C
Optical System Single beam with 1200-line/mm grating
Wavelength range(nm) 190-1100
Spectral Bandwidth(nm) 2
Wavelength Accuracy(nm) ±1
Wavelength Repeatability(nm) ≤0.5
Transmittance Accuracy(%T) ≤0.5
Stray Light(%T) 0.1 @360nm@220nm
Spectral Range 0-200%T,-3.010~3A,0-9999C(0-9999F)
Light Source Tungsten lamp & Deuterium lamp
Monitor Graphic LCD(128*64)
Data Output Flash Disk,Bluetooth,Upload to PC by USB port
Data Format CSV
Power Supply AC90-250V/50-60Hz
Dimensions (LxWxH,mm) 450x390x210
Weight (Kg) 12

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company SENOVA BIOTECH (SHANGHAI) CO., LTD.
Location No. 22, Lane 295, Jigao Road, MinHang District, Shanghai 201107, China
Contact Person Ricky Chang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.