Canon X-Ray Image Intensifier E5877J-P1K with Adjustable FOV 4/2-inch Modes
The X-ray Image Intensifier E5877J-P1K is a high-performance industrial imaging solution engineered to deliver clear and detailed X-ray images. With very high resolution and efficient soft X-ray penetration, it's ideal for non-destructive inspection applications in electronics, automotive, and aerospace industries. This lightweight, compact equipment enhances imaging efficiency and precision for reliable, accurate results.
Key Features:
- Very high resolution up to 110 Lp/cm in M mode for detailed imaging
- Compact design (226 mm length, 164 mm diameter) for easy integration
- Lightweight construction (8.0 kg) for convenient handling
- CsI direct deposit input screen reduces X-ray scatter and improves detection efficiency
- Anti-reflective coating on output screen enhances image quality
- Dual operation modes (N mode and M mode) for versatile imaging needs
- Fast setup with preheat time under 3 minutes
- Compliance with international safety standards
Technical Specifications
Mechanical Specifications:
| Overall Length | 226±3 mm |
| Maximum Diameter | 164±3 mm |
| Weight | approx. 8.0 kg |
| Nominal Entrance Field Size | typ. 100 mm |
| Output Image Diameter | 20±1 mm |
Electrical Specifications:
| Parameter | N Mode | M Mode |
|---|---|---|
| Anode Voltage | 25 to 30 kV | 25 to 30 kV |
| G3 Electrode Voltage | 1.5 to 3.5 kV | 9.0 to 12.0 kV |
| G2 Electrode Voltage | 350 to 750 V | 150 to 550 V |
| G1 Electrode Voltage | 50 to 250 V | 150 to 350 V |
| Photocathode Voltage | 0 V | |
Power Supply Specifications:
| Input Voltage | 100 to 240 Vac 30VA |
| Output Voltage | 24±1 Vdc |
| Output Current | 400 mA max. |
| Weight | approx. 1 kg |
Environmental Specifications:
| Parameter | Operating Range | Storage Range |
|---|---|---|
| Temperature | 5°C to 40°C | -15°C to 45°C |
| Humidity | 30% to 85% RH (non-condensing) | 10% to 90% RH (non-condensing) |
| Pressure | 70 to 106 kPa | 50 to 106 kPa |
Performance Specifications:
| Parameter | N Mode | M Mode |
|---|---|---|
| Central Resolution | 77 Lp/cm | 110 Lp/cm |
| Conversion Factor (Gx) | 90 cd/m² (typ.) for 10 μGy/s | 90 cd/m² (typ.) for 1 mR/s |
| Contrast Ratio | 22:1 (10% area) | - |
Safety and Handling Specifications:
| Maximum Fluoroscopic X-ray Tube Voltage | 125 kVp |
| Maximum Input Dose Rate (Continuous) | 4.37*10⁻⁴ Gy/min [50 mR/min] |
| Maximum Input Dose Rate (Pulsed) | 8.73*10⁻³ Gy/min [1 R/min] |
| Minimum Distance Between Focal Spot and Entrance Plane | 73 cm |