150kV Hamamatsu X Ray Source 5μM Spot Industrial NDT High Power 75W
Price:
Negotiable
MOQ:
1
Delivery Time:
Negotiable
Brand:
Hamamatsu
Product Description
Hamamatsu 150KV Microfocus X-Ray Source 5μm Focal Spot Industrial NDT
HAMAMATSU 150 kV MICROFOCUS X-RAY SOURCE L12161-07
FEATURES
- Focal spot size: 5 μm (at 4 W) - The sealed type X-ray tube offers sharp and clear X-ray images even at high magnification
- High power: Maximum output 75 W
- External control via RS-232C interface
- High speed ramping-up - Up to 3 times faster than conventional 150 kV microfocus X-ray sources
- No high voltage cable connection required - High voltage power supply is integrated
APPLICATIONS
- Non-destructive inspection
- X-ray CT
Applicable objects
- Semiconductor device
- Electronic component
- Printed circuit board
- Ceramic
- Plastic component
- Die casting
- Metal component
SPECIFICATIONS
GENERAL
| Parameter | Description/Value | Unit |
|---|---|---|
| X-ray tube voltage setting range | 0 to 150 | kV |
| X-ray tube current setting range | 0 to 500 | mA |
| X-ray tube voltage operational range 1 | 40 to 150 | kV |
| X-ray tube current operational range 1 | 10 to 500 | mA |
| Maximum output | Small Focus Mode: 10 W Middle Focus Mode: 30 W Large Focus Mode: 75 W |
W |
| X-ray focal spot size (Nominal value) | Small Focus Mode: 7 (5 mm at 4 W) Middle Focus Mode: 20 Large Focus Mode: 50 |
mm |
| X-ray beam angle 2 | Approx. 43 | degree |
| Focus to object distance (FOD) | Approx. 17 | mm |
| Rated output | Continuous rating | -- |
| Communication method | Interface: RS-232C (9-pin D-sub connector) | -- |
X-RAY TUBE UNIT
| Parameter | Description/Value | Unit |
|---|---|---|
| X-ray output window material / Thickness | Beryllium / 0.2 | mm |
| Target material | Tungsten | -- |
| Operating ambient temperature | +10 to +40 | °C |
| Storage ambient temperature | 0 to +50 | °C |
| Operating and storage humidity | 20 to 85 (No condensation) | % |
| Weight | Approx. 13.5 | kg |
X-RAY CONTROL UNIT
| Parameter | Description / Value | Unit |
|---|---|---|
| Input voltage (AC) | Single phase 100 to 240 (50 Hz / 60 Hz) | V |
| Power consumption | Less than 220 | W |
| Operating ambient temperature | +10 to +40 | °C |
| Storage ambient temperature | 0 to +50 | °C |
| Operating and storage humidity | 20 to 85 (No condensation) | % |
| Weight 3 | Approx. 6 | kg |
REGULATION AND STANDARDS
| Parameter | Description | Unit |
|---|---|---|
| RoHS directive | EN 50581 Category 9 | -- |
| EMC | IEC/EN 61326-1 Emission limits: CISPR 11 Group 1 Class A Immunity requirements: Table 2 | -- |
| Safety | IEC/EN 61010-1 | -- |
CONTROL SOFTWARE 4
| Parameter | Description | Unit |
|---|---|---|
| Applicable PC | PC / AT compatible | -- |
| Applicable OS | Windows® XP, 7 | -- |
| Interface | RS-232C interface | -- |
NOTE:
1. See the graph of the X-ray tube voltage / current operation range.
2. Reference value: With 50% of maximum X-ray emission.
3. This weight includes the accessories of approx. 1.5 kg.
4. The control software is provided as sample software for the purpose of MFX operation. The performance of the software is not guaranteed.
1. See the graph of the X-ray tube voltage / current operation range.
2. Reference value: With 50% of maximum X-ray emission.
3. This weight includes the accessories of approx. 1.5 kg.
4. The control software is provided as sample software for the purpose of MFX operation. The performance of the software is not guaranteed.

Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
SHENZHEN WEIMING PHOTOELECTRIC CO.,LTD.
Location
5F,B3, Anda ElectronicsIndustrial Factory, HepingCommunity, Fuhai Street, BaoanDistrict, Shenzhen
Contact Person
Jeff Chan