SHENZHEN WEIMING PHOTOELECTRIC CO.,LTD.
                                                                                                           
Verified Supplier
8 Years
Since 2018
Menu

Hamamatsu X Ray Source 130 kV Microfocus X Ray Source for Component Control

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: Negotiable
Brand: Hamamatsu
Product Description
Hamamatsu X Ray Source 130 kV Microfocus X Ray Source for Component Control
Product Overview

Hamamatsu X Ray Source 130 kV Microfocus X Ray Source L9181-02 is designed for precision component inspection and control applications.

Applicable Objects
  • Electronic components
  • Printed circuit boards
  • Plastic components
  • Metal components
Control Software Specifications
Parameter Description Unit
Applicable PC PC/AT compatible --
Applicable OS Windows® XP, 7 --
Interface RS-232C --
Technical Ratings
Parameter Description/Value Unit
Input voltage (DC) +24 (+2.4,-0) V
Power consumption Less than 120 W
Read output Continuous rating --
Operating ambient temperature +10 to +40
Storage ambient temperature 0 to +50
Operating and storage humidity 20 to 85 (No condensation) %
Compliance & Standards
Parameter Description Unit
RoHS Directive EN 50581 Category 9 --
EMC IEC/EN 61326-1
Emission limits: CISPR 11 Group 1 Class A
Immunity requirements: Table 2
--
General Specifications
Parameter Description/Value Unit
X-ray tube voltage setting range 0 to 130 kV
X-ray tube current setting range 0 to 300 μA
X-ray tube voltage operational range 40 to 130 kV
X-ray tube current operational range 10 to 300 μA
Maximum output Small focus mode: 8 W
Middle focus mode: 16 W
Large focus mode: 39 W
W
X-ray focal spot size (Nominal value) Small focus mode: 8 (5μm at 4 W)
Middle focus mode: 20
Large focus mode: 40
μm
X-ray output window material/Thickness Beryllium/0.2 mm
X-ray beam angle Approx.45 degree
Focus to object distance (FOD) Approx.13 mm
Target material Tungsten --
Weight Approx.10.5 kg
Communication method Interface: RS-232C (9-pin D-sub connector) --
Important Notes

① See the graph of the X-ray tube voltage/current operation range.

② Reference value: With 50% of maximum X-ray emission.

③ This weight includes the accessories of approx. 0.25 kg.

④ The control software is provided as a sample software for the purpose of MFX operation. The performance of the software is not guaranteed.

Hamamatsu X Ray Source product overview showing complete unit Close-up view of X Ray Source components and connectors Technical diagram showing X Ray Source specifications and dimensions

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company SHENZHEN WEIMING PHOTOELECTRIC CO.,LTD.
Location 5F,B3, Anda ElectronicsIndustrial Factory, HepingCommunity, Fuhai Street, BaoanDistrict, Shenzhen
Contact Person Jeff Chan

Request A Quote

Please check your email address.
Your message must be at least 20 characters.