Gefran M31-6-M-P10M-1-4-D 2130X000X00 10000 psi Transducer
High-Range Melt Pressure Measurement
The Gefran M31-6-M-P10M-1-4-D 2130X000X00 is an M3-series melt pressure transducer configured for a 0–10,000 psi measurement range. It is identified by Gefran ordering number F008653 and produces a nominal 3.33 mV/V output for a compatible strain-gauge measurement circuit.
This version combines a 6-inch rigid stem with an 18-inch flexible capillary. The mechanical construction separates the electrical housing from the heated extrusion-barrel connection while maintaining hydraulic pressure transmission to the internal sensing element.
Model-Specific Data
| Complete Model | M31-6-M-P10M-1-4-D 2130X000X00 |
| Ordering Number | F008653 |
| Pressure Range | 0–10,000 psi |
| Output | 3.33 mV/V |
| Accuracy Class | 0.5% FSO |
| Connector | 6-pin |
| Process Thread | 1/2-20 UNF |
| Rigid Stem | 6 inches |
| Flexible Capillary | 18 inches |
| Pressure Transmission | Mercury-filled |
| Process Temperature Capability | Up to 400°C under specified conditions |
Range and Controller Scaling
The 10,000 psi calibration is the primary difference from F008650. Even if the two models share the same stem, connector and capillary dimensions, controller scaling must correspond to the correct full-scale pressure. Substituting a 5000 psi model would change the pressure represented by a given electrical output and could affect alarm and shutdown settings.
Installation and Thermal Protection
Verify that the sensing tip is positioned correctly in the process stream without bottoming against the mounting hole. Support the housing independently and maintain a safe bend radius in the flexible section. The capillary should not contact sharp edges, moving guards or surfaces that could damage it through vibration.
Electrical Commissioning
Confirm bridge excitation, signal polarity, input sensitivity, shield termination and R-Cal procedure. Perform zero and span checks according to the controller and Gefran documentation. The 3.33 mV/V signal must not be wired as a current-loop output.
Lifecycle and Application Restrictions
The model’s product condition and current supply status must be confirmed at quotation. Mercury-filled M3 products are intended for applicable fixed industrial installations or qualifying B2B laboratory equipment. Regional restrictions and machine requirements should be reviewed before selection.
Related Models
M31-6-M-P05M-1-4-D F008650 is the corresponding 5000 psi configuration. W31-6-M-P10M-1-4-D F021516 uses FDA-compatible diathermic oil instead of mercury. K31 configurations use NaK for higher process-temperature applications.
Related models are provided for family reference only and are not automatically interchangeable.
Inquiry and Supply Notes
Provide the complete label, pressure range, controller type and photographs of the installed stem and capillary. Suggested internal-link anchor text is “Gefran M31 10000 psi Melt Pressure Transducer." Calibration status and included mating cable require confirmation.