ABB NTDI01 Digital I/O Termination Unit with 16 Individual Signals and 120 VAC Power Connections

Price Negotiable
Price: 66USD
MOQ: 1
Delivery Time: 2-3 work days
Brand: ABB
Product Description
ABB NTDI01 Digital I/O Termination Unit

The Digital I/O Termination Unit (NTDI01) is an interface for INFI 90 Process Management System I/O signals. These signals are used to control and monitor processes. Termination units provide the physical connection points for process field wiring and configure the system I/O signals.

Below is an example of an INFI 90 application using a TDI for termination.

INFI 90 application example with TDI 
NTDI01 mounting illustration
Mounting
  • Attaches to NFTP01 Field Termination Panel inside INFI 90 cabinet
  • Secured with 2 screws and spacers
I/O Capacity
  • Up to 16 individual signals
  • XU1-XU16: Signal configuration points
  • TB1-TB4: Physical terminal connections
Connectivity
  • P1: Termination cable socket to slave/master module
  • E1, E2, E3: I/O power connections (24 VDC, 125 VDC, 120 VAC)
Protection & Configuration
  • F1, F2: On-board fuses for power and field devices
  • XU17: Configures TDI signal routing for specific applications
NTDI01 protection and configuration details 
NTDI01 replacement procedures
Tools Required
  • Flat head screwdriver
  • Cross head screwdriver
  • Chip puller
  • Shunt cutting tool (AMP PN 435862-1)
Note: A TDI does not have any active components, which limits replacement requirements due to failure.
To Remove a TDI
Step 1 - Power Off

Turn off the INFI 90 cabinet power. Ensure any external power supply feeding the termination unit is also turned off.

Step 2 - Remove Field Wiring

Disconnect all wiring from TB1-TB4. Label wires if not already labeled.

Step 3 - Disconnect System Power & Ground

Remove connections from E1, E2, E3. Label wires if needed.

Step 4 - Disconnect Termination Cable

Remove NKTU01 from P1.

Step 5 - Remove TDI

Unscrew the two screws and slide the board out. Hold the unit while removing screws.

Step 6 - Dipshunt Configuration

Transfer or configure dipshunts as on the old unit. Cut straps carefully.

Step 7 - Install Fuses

Insert fuses into fuse holders (see Installing Fuses section).

Step 8 - Mount New TDI

Slide tabs into standoff slots, then secure with screws.

Step 9 - Reconnect Power, Ground, and Cable

Reconnect system power to E1/E2, ground to E3, and termination cable to P1.

Step 10 - Reconnect Field Wiring & Verify

Reconnect all wiring to TB1-TB4. Verify connections before powering on.

NTDI01 quality check and logistics information
Quality Check
  • Status: Brand New & Original
  • Warranty: 1 Year
Logistics Path
  • Carrier: DHL/FedEx/UPS/Aramex
  • ETA: Approx. 5 Days
  • Cost: Per Email Quote
Financial Rules
  • Term: 100% T/T Advance
  • Quote Validity: 30 Days
Value Added
  • Virtual Inspection: ENABLED for In-Stock Items
Contact Information

Miya Zheng [Sales Manager]
Email: sales@amikon.cn
Direct: +86-18020776792

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company AMIKON LIMITED
Location 32D units,GuoMao Building No 388 Hubin South Road Siming district Xiamen, Fujian China
Contact Person Miya

Request A Quote

Please check your email address.
Your message must be at least 20 characters.