Thermocouple Cable
PTFE / PVC / PFA Thermocouple Cable Type K with +NiCr / -NiAl Material
PTFE / PVC / PFA Thermocouple Cable Type K with +NiCr / -NiAl Material Description of chromel alumel thermocouple wire: Chromel alumel thermocouple wire consists of two conductors of different materials (usually metal alloys) that produce a voltage in the vicinity of the point where the two conductors are in contact. The voltage produced is dependent on, but not necessarily proportional to, the difference of temperature of the junction to other parts of those conductors.
20AWG K Type Thermocouple Cable PTFE Insulation For Extension Application
20AWG K Type Thermocouple Cable PTFE Insulation For Extension Application Item No. K-FP-FP-0.81 Conductor Material +Chromel, -Alumel Conductor Dia 0.81mmX2 Insulation material FEP Insulation color + yellow, -red Cable Construction Parallel Inner Shielding material / Jacket material FEP Jacket color Brown Outer Shielding Material / Insulated DIA 1.0mm Cable DIA 1.4mm*2.8mm Cable Dielectric Test DC.500v Net weight 16kg/km 1. style:Extension Wire 2. thermocouple copper wire
Industrial Grade 316L Stainless Steel Overbraided Mineral Insulated Thermocouple
Industrial-Grade 316L Stainless Steel Overbraided Mineral Insulated Thermocouple For Mineral insulated (MI) thermocouples, the basic parts are measuring element, insulation, protecting sheath. At most situation, MI thermocouples matched with flexible connector to add bending possibilities and compensation cables to improve the measure accuracy. Armor Style Thermocouple Structure 1. For the measuring wire, there are several common used type: Type K N E T J 2. Insulation
K Type Thermocouple Extension Cable With Yellow Fiberglass Insulation 1.29mm*2
K type thermocouple extension cable with yellow fiberglass insulation 1.29mm*2 Type K( CHROMEL vs ALUMEL) is used in oxidizing, insert or dry reducing atmospheres.Exposure to Vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres.Reliable and accurate at high temperatures. 1. Style:Extension Wire 2. Thermocouple extension wire Thermocouple wire Classification 1. Thermocouple level (high temperature level). This type of
Diameter 0.65mmx7/2 Type K Fiberglass Insulated Extension Cable Red Yellow
Diameter 0.65mm*7/2 type K red and yellow fiberglass insulated extension cable Type K( CHROMEL vs ALUMEL) is used in oxidizing, insert or dry reducing atmospheres.Exposure to Vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres.Reliable and accurate at high temperatures. 1. Style:Extension Wire 2. Thermocouple extension wire Thermocouple wire Classification 1. Thermocouple level (high temperature level). This type of
24AWG Chromel Alumel Thermocouple Wire With Kapton Insulation PTFE
24AWG thermocouple wire with kapton insulation and PTFE Conductor material: Material Chemical composition(%) Ni Al Cr Si Mn Chromel 90 10 Alumel 95 1-2 1-2 0.5-1.5 Structure: Conductor size 0.5mm Resistance value (ohm/m) PFA Insulation layer 0.2mm Inner braid shielding Kapton Out jacket 0.08mm OD of cable 1mmX2mm Weight/meter 0.85kg/100meter Working Temperature Long-term max standing temperature 260℃ Shor-term max standing temperature 300℃ Calibration tolerance:+/-1.1 ℃ or +/
Solid PVC Thermocouple Extension Cable Type T For Electrical Equipment
Type T Thermocouple Extension Cable Conductor specification TYPE T (Copper vs Constantan) is used or service in oxidizing, inert or reducing atmospheres or in vacuum. It is highly resistant to corrosion from atmospheric moisture and condensation and exhibits high stability at low temperatures. It is the only type with limits of error guaranteed for cryogenic temperatures. 1. Chemical Composition Material Chemical composition (%) Ni Cu Si Iron Al TP(Copper) 100 TN(Constantan)
0.5mm*2 Type J Thermocouple Cable with Iron/Constantan Conductors and PVC Insulation 20 AWG 220V
0.5mm*2 Type J Thermocouple Compensating Cable with Iron/Constantan Conductors Nickel Conductor PVC Insulation 20 AWG 220V TYPE J (Iron vs Constantan) is used in vacuum, oxidizing, inert or reducing atmospheres. Iron element oxidizes rapidly at temperatures exceeding 538'C, and therefore heavier gauge wire is recommended for longer life at these temperatures 1. Chemical Composition Material Chemical composition (%) Ni Cu Si Iron Al JP(Iron) 100 JN(Constantan) 45 55 2.
Class One 3mm K Type MI Cable Mineral Insulated Cable With SS316 Sheath
Class One 3mm K Type MI Cable Mineral Insulated Cable With SS316 Sheath Mineral insulated metal sheathed thermocouple cable designed for industrial temperature measurement applications with high reliability and precision. Product Specifications Specification Details Product Name Mineral insulated metal sheathed thermocouple cable Type K, J, T, E, R, etc Insulation Material 99.6% high purity MgO Core Number 2 wires, 3 wires, 4 wires, 6 wires Sheath Materials SS304, SS321,
K Type MI Cable Ni90Cr10/NiSi Conductor MgO Insulation Industrial Temperature Measurement with N06600 Sheath
K Type MI Cable Ni90Cr10/NiSi Conductor MgO Insulation Industrial Temperature Measurement with N06600 Sheath Mineral insulated metal sheathed thermocouple cable designed for industrial temperature measurement applications with high reliability and precision. Product Specification Details Product Name Mineral insulated metal sheathed thermocouple cable Type K, J, T, E, R, etc Insulation Material 99.6% high purity MgO Core Number 2 wires, 3 wires, 4 wires, 6 wires Sheath
High-Temperature K-Class Cable | 2*0.6mm Twisted Pair | ANSI MC96.1 | -270°C to 1372°C
High-Temperature K-Class Cable | 2*0.6mm Twisted Pair | ANSI MC96.1 | -270°C to 1372°C Specifications: 1. Style:Compensation Wire 2. Thermocouple J wire Thermocouple J wire Classification 1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc. 2. Compensating wire level (low temperature level). This type of thermocouple
RTD PT100 Thermocouple Cable Double Fiberglass Insulated Tinned/Silver/Nickel Plated Copper
RTD PT100 Thermocouple Cable Double Fiberglass Insulated Tinned/Silver/Nickel Plated Copper 1. Chemical Composition Material Chemical composition (%) Ni Cu Si Mn other P(copper) >99.9 99.9 196 1.71(20℃) >30 N(copper) 8.9 1084 >196 1.71(20℃) >30 2. Size and Insulation Material Reference Size and Insulation Material Reference Type Cross-Section (mm2) Diameter Insulation Material/ Jacket Material Shield AWG (SingleCore) mm (Multi-Core) SC RC BC KCA KCB KX NC NX EX JX LX 0.07 - 1
K Type Thermocouple Mineral Insulated With SS304 Sheath Extension Cable Fast Response
Mineral Insulated K Type Thermocouple With 2 Contacts Connector SS304 Sheath Extension Cable Fast Response For Mineral insulated (MI) thermocouples, the basic parts are measuring element, insulation, protecting sheath. At most situation, MI thermocouples matched with flexible connector to add bending possibilities and compensation cables to improve the measure accuracy. Armor Style Thermocouple Structure For the measuring wire, there are several common used type: Type K N E T
High Temperature Silica Fiber Insulated Type N Thermocouple Cable
High Temperature Silica Fiber Insulated type N thermocouple cable Insulation: FEP, TOFLON, PVC, PTFF, PFA, Fiberglass, Silicone rubber TYPE N (NiCrSi Vs.NiCrMg) is used in oxidizing, inert or dry reducing atmospheres. Exposure to vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres. Reliable and accurate at high temperatures. 1. Chemical Composition Material Chemical composition (%) Ni Cr Si Mg Al NP(NiCrSi) bal 13.7-14.7
High-Temp Ni80Cr20 Heating Wire With High-Silica Fiber Insulation 800°C Continuous For Industrial Furnace Systems
High-Temp Ni80Cr20 Heating Wire with High-Silica Fiber Insulation, 800°C Continuous for Industrial Furnace Systems Product brief introduction Kapton Fiberglass Insulated NiCr 0Cr20Ni80 Nickel alloy wire for High Temperature Heating Ohmalloy not only produce the bare resistance wire. It can also provide the resistance wire with insulation as we have 30 years in producing the thermocouple extension cable. The insulated resistance wire are widely used for standard resistor,
Industrial-Grade Mica Tape Impregnated High-Temp Wire UL-Certified -80°C To 500°C
Industrial-Grade Mica Tape Impregnated High-Temp Wire, UL-Certified (-80°C to 500°C) Cable Specification Item Name Mica Wrap Fiber Glass PWHT Thermocouple Type K Cable Item Number K-BH-MA-BH-0.6 Conductor Material +Chromel -Alumel Conductor Dia 2*0.6mm( ±0.01mm) Inner Insulation and Thickness High Temperature Fiberglass (long term: 600℃, short term: 700℃) Mica Wrapped(650℃) Inner Insulation Diameter 1.2mm(±0.2mm) Outer Jacket Material High Temperature Fiberglass (long term:
ANSI Green Type T Thermocouple Mini Plug Cu / Constantan For Cryogenic Sensors
ANSI Green Type T Thermocouple Mini Plug (Cu/Constantan) for Cryogenic Sensors Thermocouple Type K Middle Size Connector Round Chromel Alumel Pin Thermometer Plug ANSI Connector Type Middle Type(same as OMEGA middle type) Connector Dimension HxWxT:48.95mmx25.25mmx13.48mm Pin Material Chromel Alumel Connector Standard ANSI Standard Connector Part Male/Female Connector Application Connecting thermocouple probe/wire terminals to extension /compensating cables Thermocouple Type K
Platinum Rhodium Type B/R/S Mineral Insulated MI Thermocouple Cable For Heating Elements
Mineral Insulated Thermocouple Cable Type K J RTD N S Stainless Steel Sheath It is known as inorganic substance insulation thermocouple cable internationally. It is the mould-pressed solid integrity of combined stainless steel protective pile (1) magnesium oxide insulation powder. (2) and thermocouple thread materials . (3) Its merits include press endurance, vibration resistance, bending capability, mini size, quick respond, etc. It acts as the key material of sheath
1.29mm*2 K Type Thermocouple Compensation Cable With Yellow Fiberglass Insulation
K type thermocouple extension cable with yellow fiberglass insulation 1.29mm*2 Type K( CHROMEL vs ALUMEL) is used in oxidizing, insert or dry reducing atmospheres.Exposure to Vacuum limited to short time periods. Must be protected from sulfurous and marginally oxidizing atmospheres.Reliable and accurate at high temperatures. 1. Style:Extension Wire 2. Thermocouple extension wire Thermocouple wire Classification 1. Thermocouple level (high temperature level). This type of
Type J Fe CuNi45 Thermocouple Wire 0.193mm Diameter Compliant for High-Temperature Sensing
Type J (Fe CuNi45) Thermocouple Wire 0.193mm Diameter Compliant for High-Temperature Sensing TYPE J (Iron vs Constantan) is used in vacuum, oxidizing, inert or reducing atmospheres. Iron element oxidizes rapidly at temperatures exceeding 538'C, and therefore heavier gauge wire is recommended for longer life at these temperatures 1. Chemical Composition Material Chemical composition (%) Ni Cu Si Iron Al JP(Iron) 100 JN(Constantan) 45 55 2. Physical properties and Mechanical