Refrigerant Desiccant
XH-5 1.7mm Molecular Sieve Air Dryer
Product Description XH-5 used commercially for dehydration and drying of refrigerants R12, R22. XH-7 used for dehydration and drying of new refrigerants R-134a in household and commercial refrigerators, iceboxes and air conditioners. It is also used for specialized refrigerants such as butane in "green" refrigerators. XH-9 used commercially in drying refrigerants in air conditioners, iceboxes and refrigerators in cars, station wagons,
CAS 1318-02-1 XH-7 Refrigerant Desiccant
Product Description The service life of most refrigeration systems depends on when the refrigerant leaks. The leakage of refrigerants is caused by the corrosion of pipes by the harmful substances produced by the refrigerant and the trace moisture contained in it. The molecular sieve has the characteristics of low dew point control, high strength, low wear and does not damage the chemical stability of the refrigerant. Characteristics of
CAS 1318-02-1 XH-7 Refrigerant Desiccant
Product Description The service life of most refrigeration systems depends on when the refrigerant leaks. The leakage of refrigerants is caused by the corrosion of pipes by the harmful substances produced by the refrigerant and the trace moisture contained in it. The molecular sieve has the characteristics of low dew point control, high strength, low wear and does not damage the chemical stability of the refrigerant. Characteristics of
2.4mm XH-5 Refrigerant Desiccant Chemical Auxiliary Agent
Product Description XH seriesMolecular Sieve regenerated and reused. To regenerate the sieve you need to remove the adsorbed moisture and other materials. To regenerate XH series Molecular Sieve heat to 250℃to 450℃.The service life of most refrigeration systems depends on when the refrigerant leaks. The leakage of refrigerants is caused by the corrosion of pipes by the harmful substances produced by the refrigerant and
1.7mm XH-7 Refrigerant Desiccant Beads
Product Description Molecular Sieve type XH-7 is an alkali alumina silicate. It has high chemical compatibility with the particular refrigerant, high mechanical strength and particle integrity necessary to prevent crushing or attrition. Also with high moisture adsorption. XH-7 molecular sieve mainly applied to drying for R-134a and butane refrigerant used by refrigerator,freezer and air-condition. Description of refrigerant select
2.4mm Refrigerant Molecular Sieve Desiccant
XH-7 Molecular Sieve Pellets Introduction XH refrigerant desiccant effectively remove moisture and other contaminants from refrigerant, thus, avoiding ice formation and protecting the system from blockage and corrosion. With higher crush strength and lower attrition, they are playing an important role in minimizing the refrigerant dew point and widely used in different kinds of refrigerant plants. XH-5 molecular sieve is mainly used
Low Wear 0.80kg/L Refrigerant Desiccant XH-7
Product Description XH refrigerant desiccant effectively remove moisture and other contaminants from refrigerant, thus, avoiding ice formation and protecting the system from blockage and corrosion. With higher crush strength and lower attrition, they are playing an important role in minimizing the refrigerant dew point and widely used in different kinds of refrigerant plants. Description of refrigerant select molecular sieve The
Molecular Sieve Desiccant Beads XH-7
High Purity Product Description The service life of most refrigeration systems depends on when the refrigerant leaks. The leakage of refrigerants is caused by the corrosion of pipes by the harmful substances produced by the refrigerant and the trace moisture contained in it. The molecular sieve has the characteristics of low dew point control, high strength, low wear and does not damage the chemical stability of the refrigerant. Descriptio
Low Wear Rate Refrigerant Desiccant 1.7mm XH-5
Product Description Refrigerants mainly consist of chloride and fluoride of containing hydrocarbons, refrigeration principle is that refrigerant quickly spread. In the process of its diffusion, some of water leakage and freeze in diffuser valve and block system, at the same time, the refrigerant hydrolysis to generate the corrosive gas such as hydrogen chloride and fluoride, the corrosive gas can cause refrigerant leakage,