Guangzhou Rongtao Medical Tech LTD.
                                                                                                           
Verified Supplier
12 Years
Since 2014
Menu
Home Products Ultrasound Probe Repair

Ultrasound Probe Repair

China GE C1-5-D Convex Array Ultrasound Probe Transducer Maintenance Change Crystal for sale

GE C1-5-D Convex Array Ultrasound Probe Transducer Maintenance Change Crystal

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

GE C1-5-D Convex Array Ultrasound Probe Transducer Maintenance Change Crystal Model: GE C1-5-D Fault Phenomenon: The probe has been repaired before, the cable is aging, and the strain relief is aging and damaged. About 3 channels of the computer image are missing, there has interference while waving the cable, and the cable is faulty. Suggestion: Replace strain relief and connector cable, and crystal 2D Probe Repair Service Brand GE,Siemens,Hitachi Aloka,Toshiba,Biosound

China GE C1-5-D Ultrasound Probe Repair Strain Relief Lens Replacement for sale

GE C1-5-D Ultrasound Probe Repair Strain Relief Lens Replacement

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

GE C1-5-D Ultrasound Probe Repair Strain Relief Lens Replacement Model: GE C1-5-D Fault Phenomenon: about 3 images of the machine are missing, the image will be missing while moving the line, and the connector cable is faulty. Suggestion: Replace the strain relief and connector cable. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement

China Aloka UST-5299 Ultrasound Transducer Probe Replace Crystal Solutions for sale

Aloka UST-5299 Ultrasound Transducer Probe Replace Crystal Solutions

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

Aloka UST-5299 Ultrasound Transducer Probe Replace Crystal Solutions Model: Aloka UST-5299 Fault Phenomenon: The connector cable is aging, the housing cover is deformed and there are gaps, the computer image is seriously missing and interference, the crystal is broken. Maintenance Plan: Replace housing cover and crystal. Other Aloka probes we can repair: Brand Model Compatible System Aloka UST-5024N-3.5 SSD-256,280 Aloka UST-52101N SSD-5500, Alpha 5, Alpha 7 Aloka ust-52105

China GE RAB4-8-RS Ultrasound Probe Repair Dome Original Condition Oil Filling for sale

GE RAB4-8-RS Ultrasound Probe Repair Dome Original Condition Oil Filling

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

GE RAB4-8-RS Ultrasound Probe dome Repair Original Condition Oil Filling The dome is damaged and leaking oil Suggestion: replace the dome (filling oil) Other hot GE models we can repair: GE C1-5-D GE C1-5-RS GE 4C GE 4C-RS GE 4C-A GE 4C-D GE 4C-SC GE E8C/E8C-RS GE E8CS GE RIC5-9-D GE 3CRF-D GE C1-6-D GE RAB4-8-RS GE RAB2-5-RS GE 6S-RS GE 12L-RS GE 3SC-RS GE L6-12-RS GE 11L GE 11L-D GE 12L-RS GE 8C GE 3S GE 3S-RS Common ultrasound Probe Damage(Specialty 3D/4D Volume probes)

China Aloka UST-5299 Ultrasound Transducer Probe Replace Crystal Solutions for sale

Aloka UST-5299 Ultrasound Transducer Probe Replace Crystal Solutions

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

Aloka UST-5299 Ultrasound Transducer Probe Replace Crystal Solutions Model: Aloka UST-5299 Fault Phenomenon: The connector cable is aging, the housing cover is deformed and there are gaps, the computer image is seriously missing and interference, the crystal is broken. Maintenance Plan: Replace housing cover and crystal. Other Aloka probes we can repair: Brand Model Compatible System Aloka UST-5024N-3.5 SSD-256,280 Aloka UST-52101N SSD-5500, Alpha 5, Alpha 7 Aloka ust-52105

China Aloka UST-5299 Ultrasound Transducer Probe Replace Housing And Connector for sale

Aloka UST-5299 Ultrasound Transducer Probe Replace Housing And Connector

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

Aloka UST-5299 Ultrasound Transducer Probe Replace Housing And Connector Model: Aloka UST-5299 Fault Phenomenon: The connector cable is aging, the housing cover is deformed and there are gaps, the computer image is seriously missing and interference, the crystal is broken. Maintenance Plan: Replace housing cover and crystal. Other Aloka probes we can repair: Brand Model Compatible System Aloka UST-5024N-3.5 SSD-256,280 Aloka UST-52101N SSD-5500, Alpha 5, Alpha 7 Aloka ust

China Micro Convex Endocavity 11mm Ultrasound Transducer Probe GE E8C-RS for sale Video

Micro Convex Endocavity 11mm Ultrasound Transducer Probe GE E8C-RS

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

GE E8C-RS Micro Convex Endocavity 11mm Ultrasound Transducer/Probe 1. Type:convex 2. Frequency: 4-10mhz 3. Compatible system: Portable Voluson, Logiq, and Vivid series 4. Application: OB/GYN & urology 5. Condition: original, in good working condition 6. With 60 days warranty 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief

China Hitachi EUP-C715 Abdominal Ultrasound Probe Imaging Diagnosis for sale

Hitachi EUP-C715 Abdominal Ultrasound Probe Imaging Diagnosis

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

Hitachi EUP-C715 Abdominal Ultrasound Probe Imaging Diagnosis 1. Type: convex 2. Frequency:5-1MHz 3. Compatible system: EUB-405/500/525/2000/5500, H21/EUB-6500, EUB-7500, EUB-8500 Logos 4. Application:abdominal 5. Condition: original, in good working condition 6. With 60 days warranty Other Hitachi probes we can offer: Brand Model Compatible System Hitachi EUP-C314G EUB-405/525/555 Hitachi EUP-C514 EUB-6000 Hitachi EUP-C516 EUB-405/500/525/2000/5500/6500/8500 Hitachi EUP-C715

China GE 4C-RS Curved Array Abdominal Ultrasound Probe Hospital Instrument for sale

GE 4C-RS Curved Array Abdominal Ultrasound Probe Hospital Instrument

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

GE 4C-RS Curved Array Abdominal Ultrasound Probe Hospital Instrument 1.Type:convex 2.Frequency: 1.8 - 6.0 MHz 3.Compatible system: Vivid i Square/ Logiq e/ Vivid e 4.Application: Abdominal & OB/GYN 5.Condition: pre-owned one, original, in good working condition 6.With 60 days warranty Ultrasound probe Types (Classified by diagnostic part) 1 Ophthalmic ultrasound probe 2 Cardiac ultrasound probe 3 Abdominal ultrasound probe 4 Uterine ultrasound probe 5 Anal ultrasound probe 6

China GE Logiq E9 ML6-15-D Breast Ultrasound Probe Repair Linear Vascular Transducer for sale

GE Logiq E9 ML6-15-D Breast Ultrasound Probe Repair Linear Vascular Transducer

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

GE Logiq E9 ML6-15-D Breast Ultrasound Probe Repair Linear Vascular Transducer 1. Type: Linear 2.Compatible system: Logiq E9, Logiq S8, Vivid E9, Voluson E8 Expert 3. Frequency: 4.5-15 MHz. 4. Application: Vascular, Breast, Small Parts, Musculoskeletal, Thyroid 5. With 60 days warranty after fixed and 3-5 working days to repair 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity

China GE 11L-D Linear Ultrasound Probe Hospital Equipment Imaging Small Parts for sale Video

GE 11L-D Linear Ultrasound Probe Hospital Equipment Imaging Small Parts

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

GE 11L-D Linear Ultrasound Probe Hospital Equipment Imaging Small Parts 1. Type: Linear 2.Compatible system: Logiq E9, Vivid E9, Vivid E95, Voluson E6, Voluson E8 3. Frequency: 5.9-17.3 MHz. 4. Application: Vascular, MSK, Thyroid, and Contrast 5. With 60 days warranty after fixed and 3-5 working days to repair Knowledge point The GE 11L-D linear ultrasound transducer is a high-frequency linear transducer for GE’s premium ultrasound machines. It has a frequency range of 5.0-12

China GE RIC6-12-D Ultrasound Probe Repair 4D Dome Motor Replacement Solution for sale

GE RIC6-12-D Ultrasound Probe Repair 4D Dome Motor Replacement Solution

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

GE RIC6-12-D Ultrasound Probe Repair 4D Dome Motor Replacement Solution Model: GE RIC6-12-D Fault Phenomenon: Error reported in the 4D, oil sac falling off and leaking oil. Suggestion: Repair 4D and Replace the Dome. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal/Array

China GE C1-6-D Ultrasound Probe Repair Strain Relief Lens Replacement Service Solution for sale Video

GE C1-6-D Ultrasound Probe Repair Strain Relief Lens Replacement Service Solution

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

GE C1-6-D Ultrasound Probe Repair Strain Relief Lens Replacement Service Solution Model: GE C1-6-D Fault Phenomenon: It has been repaired before, the connector cable is aging, the strain relief is aging and damaged, about 3 images of the machine are missing, the image will be missing while moving the line, and the connector cable is faulty. Suggestion: Replace the strain relief and connector cable. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound

China Original Linear Array Ultrasound Probe Medical Parts Probe Repair GE Logiq E9 11L-D for sale

Original Linear Array Ultrasound Probe Medical Parts Probe Repair GE Logiq E9 11L-D

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

GE Logiq E9 11L-D Linear Array Ultrasound Probe Medical Parts Probe Repair 1. Type: Linear 2.Compatible system: Logiq E9, Vivid E9, Vivid E95, Voluson E6, Voluson E8 3. Frequency: 5.9-17.3 MHz. 4. Application: Vascular, MSK, Thyroid, and Contrast 5. With 60 days warranty after fixed and 3-5 working days to repair 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range

China Hitachi EUP-C715 Convex Abdominal Ultrasound Probe Repair Surgical Instruments for sale Video

Hitachi EUP-C715 Convex Abdominal Ultrasound Probe Repair Surgical Instruments

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

Hitachi EUP-C715 Surgical Instruments Convex Abdominal Repair Ultrasound Probe 1.Model: EUP-C715 2.Repair Time: 2-5 days 6.With 60 days warranty Parts of GE probes we can offer: Brand Model Compatible System GE 3.5C Logiq 3/ Logiq 5/ Logiq 7/ Logiq 9/ Logiq A5/ Logiq P5/ Logiq S6/Vivid7 GE 3C Logiq 3/ Logiq 5 GE 3Cb Logic 200 Pro GE 3CRF Logiq S6 GE 3CRF-D Logiq S8/ Logiq E9 GE 3SP LOGIQ P GE 3Sp-D Voluson E6/Voluson E8 / Bt08 & Higher vension GE 3S vivid & Logiq series GE 3S

China GE RIC6-12-D Ultrasound Probe Repair 4D Motor For Surgical Imaging for sale

GE RIC6-12-D Ultrasound Probe Repair 4D Motor For Surgical Imaging

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

GE RIC6-12-D Ultrasound Probe Repair 4D Motor Repair Medical Ultrasound Probe GE RIC6-12-D Repair 4D and Dome Replacement Model: GE RIC6-12-D Fault Phenomenon: Error reported in the 4D, oil sac falling off and leaking oil. Suggestion: Repair 4D and Replace the Dome. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief replacemen

China Samsung L3-12A Ultrasound Probe Transducer Replace Strain Relief Cable And Lense for sale

Samsung L3-12A Ultrasound Probe Transducer Replace Strain Relief Cable And Lense

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

Samsung L3-12A Ultrasound Probe Transducer Replace Strain Relief/Cable and Lense Model: Samsung L3-12A Fault Phenomenon: The cable is wrapped with tape, the cable is aged and broken, the strain relief is aged, the image on the machine has a dark shadow, and the lense is damaged. Maintenance Plan: Replace the strain relief, cable and lense. Other hot models we can repair: Brand Model Aloka UST-52101 Aloka UST-52105 Aloka UST-5299 Aloka UST-5412 Aloka UST-5413 Aloka UST-9118

China GE C1-6-D Ultrasound Probe Repair Strain Relief Lens Replacement for sale Video

GE C1-6-D Ultrasound Probe Repair Strain Relief Lens Replacement

Price: Negotiable
MOQ: 1
Delivery Time: 1-5 work days

GE C1-6-D Ultrasound Probe Repair Strain Relief and Connector Cable Replacement Model: GE C1-6-D Fault Phenomenon: It has been repaired before, the connector cable is aging, the strain relief is aging and damaged, about 3 images of the machine are missing, the image will be missing while moving the line, and the connector cable is faulty. Suggestion: Replace the strain relief and connector cable. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound

China GE 8C-RS Micro Convex Ultrasound Transducer Probe Replace Parts for sale Video

GE 8C-RS Micro Convex Ultrasound Transducer Probe Replace Parts

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

GE 8C-RS Micro Convex Ultrasound Transducer Probe Replace Parts For Ultrasound Probe GE 8C-RS Micro Convex Ultrasound Transducer Probe Replace Parts ​Model: GE 8C-RS Fault Phenomenon: The lens is damaged, the cable is yellow and aging, the image on the computer is seriously missing, the crystal and the cable are broken, and the cable length is about 1.5 meters. Maintenance Plan: Replace the original crystal array and cable 2D Probe Repair Service Brand GE,,Siemens,Hitachi

China GE E8C-RS Ultrasound Transducer Crystal Array Replacement And Connector Ultrasound Transducer Repair for sale Video

GE E8C-RS Ultrasound Transducer Crystal Array Replacement And Connector Ultrasound Transducer Repair

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

GE E8C-RS Ultrasound Transducer Crystal Array Replacement and Connector Housing Repair Model: GE E8C-RS Fault Phenomenon: The connector housing is degummed and slightly worn, the lens falls off, and the image on the machine is missing two or so. Suggestion: Replace the crystal array and repair the connector housing (the image is not guaranteed, the matching layer needs to be dismantled and repaired, and inspect the lens. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka