Ultrasound Probe Repair
Original Linear Array Ultrasound Probe Medical Parts Probe Repair GE Logiq E9 11L-D
GE Logiq E9 11L-D Linear Array Ultrasound Probe Medical Parts Probe Repair 1. Type: Linear 2.Compatible system: Logiq E9, Vivid E9, Vivid E95, Voluson E6, Voluson E8 3. Frequency: 5.9-17.3 MHz. 4. Application: Vascular, MSK, Thyroid, and Contrast 5. With 60 days warranty after fixed and 3-5 working days to repair 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range
GE Voluson S8 Ultrasound Probe Repair C1-5-RS Convex Array Transducer
GE Voluson S8 Ultrasound Probe C1-5-RS Convex Array Transducer Repair 1. Type: Convex 2.Compatible system: Logiq e R7, Logiq P9, Logiq Q e, Vivid iq, Voluson S8 3. Frequency: 1.5-5 MHz. 4. Application: OB-GYN, urology, pediatrics and abdominal imaging applications 5. With 60 days warranty after fixed and 3-5 working days to repair 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity
GE Voluson E8 Ultrasound Probe IC5-9-D Endovaginal Transducer Repair
GE Voluson E8 Ultrasound Probe IC5-9-D Endovaginal Transducer Repair 1. Type: Endovaginal 2.Compatible system: Logiq E9, Logiq S7, Logiq S8, Voluson E6, Voluson E8 3. Frequency: 3.3-8.6 MHz. 4. Application: OB/GYN, Urology 5. With 60 days warranty after fixed and 3-5 working days to repair 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement
Wisonic L15-4 Ultrasound Transducer Probe Replace Acoustic Lens For Color Doppler
Lens Replacement for Wisonic L15-4 Ultrasound Transducer Probe Model: Wisonic L15-4 Fault description: The lens is blistered and the acoustic lens cannot detect. Maintenance scheme: Replace acoustic lens. Common Probe failure 1. Lens: Acoustic lens damage or bulge 2. Cable: the cable is damaged and the shell is cracked 3. Image attenuation: aging attenuation 4. Shadow: dark vertical line 5. Not recognized: probe not recognized 6. Interference: probe interference 2D Probe
CA123 Ultrasound Probe Repair Maintenance Replace Crystal
Biosound Biosound CA123 Ultrasound Transducer Probe Replace Crystal Model: Biosound Biosound CA123 Fault description: The image on the machine is seriously missing and the crystal is broken. Maintenance scheme: Replace crystals. We provide repair service on most common probes (Linear, convex, sector), 3D/4D transducers, and Endocavity/TEE probes. With 10 years experiences on probe repair, our technical engineer team owns the most advanced probe repair processes, which enables us
Biosound Biosound SL1543 Linear Array Ultrasound Probe Repair Replace Lens And Crystal
Biosound Biosound SL1543 Linear Array Ultrasound Transducer Probe Replace Lens and Crystal Model: Biosound SL1543 Fault description: The lens is broken, the capacitor is grounded at three points, and there are three dark shadows on the machine. Maintenance scheme: Replace lens and crystals. We provide repair service on most common probes (Linear, convex, sector), 3D/4D transducers, and Endocavity/TEE probes. With 10 years experiences on probe repair, our technical engineer team
Toshiba PVT-375BT Ultrasound Transducer Probe Connector Housing Crystal Array Cable Replacement
Toshiba PVT-375BT Ultrasound Transducer Connector Housing/Crystal Array/Cable Replacement 1. Model: Toshiba PVT-375BT 2. Fault Phenomenon: The cable is wrapped with tape, the connector housing is worn and broken, the matching layer of the crystal array is aged and damaged, the cable is aged and broken, the strain relief is aged, the lens is peeled off, the image on the machine is seriously missing, and the crystal array is damaged. 3. Suggestion: Replace the connector housing
GE 9L-RS Ultrasound Probe Maintenance Replace Acoustic Lens Probe Repair
GE 9L-RS Ultrasound Probe Maintenance Replace Acoustic Lens Model: GE 9L-RS Fault Phenomenon: The lens is blistered, and the images on the machine have dark shadows. Suggestion: Replace the acoustic lens. 2D Probe Repair Service Brand GE,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal/Array replacement,Plastic
GE C1-6-D Convex Array Ultrasound Probe Transducer Maintenance Strain Relief And Connector Cable Replacement
Probe Maintenance for GE C1-6-D Ultrasound Transducer Strain Relief and Connector Cable Replacement Model: GE C1-6-D Fault Phenomenon: The probe has been repaired before, the cable is aging, and the strain relief is aging and damaged. About 3 channels of the computer image are missing, there has interference while waving the cable, and the cable is faulty. Suggestion: Replace strain relief and connector cable. 2D Probe Repair Service Brand GE,Siemens,Hitachi Aloka,Toshiba
GE IC5-9-D Ultrasound Probe Repair Replace Original Crystal
Probe Maintenance for GE IC5-9-D Ultrasound Transducer Replace the Original Crystal Model: GE IC5-9-D Fault Phenomenon: The cable is aging and discolored, the housing cover is worn and discolored, there has some missing the image on the computer and crystals are damaged. Suggestion: Replace the original crystal. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range
GE RM6C Ultrasound Probe Repair Service 4D Maintenance
Ultrasound Transducer Repair Service GE RM6C 4D Maintenance Model: GE RM6C Fault Phenomenon: 4D doesn't work, and the housing cover has scratches Suggestion: Repair 4D. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal/Array replacement,Plastic housing repair,Connecting cable
GE C1-6-D Ultrasound Probe Repair Strain Relief And Connector Cable Replacement
GE C1-6-D Ultrasound Probe Repair Strain Relief and Connector Cable Replacement Model: GE C1-6-D Fault Phenomenon: It has been repaired before, the connector cable is aging, the strain relief is aging and damaged, about 3 images of the machine are missing, the image will be missing while moving the line, and the connector cable is faulty. Suggestion: Replace the strain relief and connector cable. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound
GE E8C-RS Ultrasound Transducer Crystal Array Replacement and Connector Housing Repair
GE E8C-RS Ultrasound Transducer Crystal Array Replacement and Connector Housing Repair Model: GE E8C-RS Fault Phenomenon: The connector housing is degummed and slightly worn, the lens falls off, and the image on the machine is missing two or so. Suggestion: Replace the crystal array and repair the connector housing (the image is not guaranteed, the matching layer needs to be dismantled and repaired, and inspect the lens. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka
GE C2-5-RS Ultrasound Transducer Crystal Array And Connector Housing Replacement
GE C2-5-RS Ultrasound Transducer Crystal Array and Connector Housing Replacement Model: GE C2-5-RS Fault Phenomenon: Lens foaming. 31 pieces of crystal array is damaged. Maintenance Plan: Replace the crystal and connector housing. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal
GE RIC6-12-D Ultrasound Transducer Probe 4D Maintenance
GE RIC6-12-D Ultrasound Transducer Probe 4D Maintenance Model: GE RIC6-12-D Fault Phenomenon: 1. The cable is aging and hard. 2. The whole probe is aging. 3. 4D does not work. 4. The crystal is missing Maintenance Plan: Repair 4D(replace the dome, due to the overall aging of the probe, the stability of the later use needs to be notified) 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector
GE RIC5-9-D 3D 4D Endovaginal Ultrasound Transducer Repair Dome Replacement
GE RIC5-9-D 3D 4D Endovaginal Ultrasound Transducer Maintenance Repair 4D and Dome Replacement Model: GE RIC5-9-D Fault Phenomenon: 4D does not work Suggestion: Repair 4D, replace dome (oil filling) 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal/Array replacement,Plastic
GE RAB6-D 4D Ultrasound Transducer Repair Cardiovascular Ultrasound Machine
GE RAB6-D 4D Ultrasound Transducer Repair Cardiovascular Ultrasound Machine Model: GE RAB6-D Fault Phenomenon: There is an error for 4D. Suggestion: Repair 4D. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal/Array replacement,Plastic housing repair,Connecting cable repair Common
Obstetrics GE 8C-RS Ultrasound Probe Repair Lens And Cable Repair Service
GE 8C-RS Ultrasound Probe Repair Lens And Cable Repair Service 1. Type: Curved Array 2.Compatible system: Abdominal, Obstetrics, Gynaecology 3. Frequency: 4.0 - 10.0 MHz. 4. Application: Abdominal, Cardiac 5. With 60 days warranty after fixed and 3-5 working days to repair 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief
GE RAB4-8-RS 4D Ultrasound Probe Repair Monitor Repair Dome
GE RAB4-8-RS 4D Ultrasound Probe Repair Monitor Repair Dome 1. Type: 3D/4D Curved Array 2.Compatible system: GE Voluson i; GE Voluson e 3. Frequency: 4.0 - 8.0 MHz. 4. Application: Obstetrics, Gynaecology 5. With 60 days warranty after fixed and 3-5 working days to repair 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief
GE RIC5-9A-RS Ultrasound Transducer Crystal Array And Dome Replacement 4D And Circuit Repairing
GE RIC5-9A-RS Ultrasound Transducer Crystal Array and Dome Replacement 4D and Circuit Maintenance Model: GE RIC5-9A-RS Fault Phenomenon: The dome leaks oil, the 4D does not work, the image is missing, the crystal is broken, the image has ghosting, and the circuit is faulty. Suggestion: Replace the original crystal, replace the dome, repair the 4D and the circuit. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type