China GE Vivid S6 Ultrasound Machine Repair Interference In CW Mode Replace PIB Board for sale

GE Vivid S6 Ultrasound Machine Repair Interference In CW Mode Replace PIB Board

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

GE Vivid S6 Ultrasound Machine Repair Interference In CW Mode Replace PIB Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Interference In CW Mode Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related to GE that we can offer: GE vivid E9 BEP Power P/N::GA200040 or 5145000-10 GE vivid E9 Main Power P/N::GA200004 GE vivid E9 Control Panel GE Logiq E9/vivid E9 GTX 2.4/GTX-TLP

China Hitachi ARIETTA 60 Can Not Start Up Ultrasound Machine Repair Replace BE Board for sale Video

Hitachi ARIETTA 60 Can Not Start Up Ultrasound Machine Repair Replace BE Board

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Hitachi ARIETTA 60 Can Not Start Up Ultrasound Machine Repair Replace BE Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Can Not Start Up Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related that we can offer: Brand Compatible System Description Hitachi EUB-5500 CW Doppler board EZU-ST5 Hitachi EUB-5500 MAP-A WU8012-2 Hitachi EUB-5500 MAP WB8002-A Hitachi EUB-5500

China Hitachi Aloka Ascendus Image Missing Ultrasound Machine Repair Replace TRX Board for sale

Hitachi Aloka Ascendus Image Missing Ultrasound Machine Repair Replace TRX Board

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Aloka Hitachi Ascendus Image Missing Ultrasound Machine Repair Replace TRX Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Image Missing Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related that we can offer: Brand Compatible System Description Hitachi EUB-5500 CW Doppler board EZU-ST5 Hitachi EUB-5500 MAP-A WU8012-2 Hitachi EUB-5500 MAP WB8002-A Hitachi EUB-5500

China Aloka Hivision Ascendus Report Error Ultrasound Machine Repair Replace Cell Board for sale Video

Aloka Hivision Ascendus Report Error Ultrasound Machine Repair Replace Cell Board

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Aloka Hivision Ascendus Report Errors Ultrasound Machine Repair Replace Cell Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Report Error And Show Blurred Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related that we can offer: Brand Compatible System Description Hitachi EUB-5500 CW Doppler board EZU-ST5 Hitachi EUB-5500 MAP-A WU8012-2 Hitachi EUB-5500 MAP WB8002-A

China Replace 5541 Mainboard Ultrasound Machine Repair Aloka Prosound A7 Report 5541 And Unable To Start Up for sale

Replace 5541 Mainboard Ultrasound Machine Repair Aloka Prosound A7 Report 5541 And Unable To Start Up

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Aloka Prosound A7 Report 5541 And Unable To Start up Ultrasound Machine Repair Replace 5541 Mainboard 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Report 5541 And Unable To Start up Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related that we can offer: Brand Compatible System Description Hitachi EUB-5500 CW Doppler board EZU-ST5 Hitachi EUB-5500 MAP-A WU8012-2 Hitachi EUB

China Aloka Alpha 7 Report Error Ultrasound Machine Repair Replace RX Beamformer Board EP539501 for sale

Aloka Alpha 7 Report Error Ultrasound Machine Repair Replace RX Beamformer Board EP539501

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Aloka Alpha 7 Report Error Ultrasound Machine Repair Replace RX Beamformer Board EP539501 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Report Error And Show Blurred Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related that we can offer: Brand Compatible System Description Hitachi EUB-5500 CW Doppler board EZU-ST5 Hitachi EUB-5500 MAP-A WU8012-2 Hitachi EUB-5500 MAP WB8002

China Hitachi HI VISION Report Error And Show Blurred Ultrasound Machine Repair Replace Cell Board for sale

Hitachi HI VISION Report Error And Show Blurred Ultrasound Machine Repair Replace Cell Board

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Hitachi HI VISION Report Error And Show Blurred Ultrasound Machine Repair Replace Cell Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Report Error And Show Blurred Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related that we can offer: Brand Compatible System Description Hitachi EUB-5500 CW Doppler board EZU-ST5 Hitachi EUB-5500 MAP-A WU8012-2 Hitachi EUB-5500 MAP

China Hitachi Aloka Ascendus Image Shadow Ultrasound Machine Repair Replace TRX Board for sale

Hitachi Aloka Ascendus Image Shadow Ultrasound Machine Repair Replace TRX Board

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Hitachi Aloka Ascendus Image Shadow Ultrasound Machine Repair Replace TRX Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Image Shadow Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related that we can offer: Brand Compatible System Description Hitachi EUB-5500 CW Doppler board EZU-ST5 Hitachi EUB-5500 MAP-A WU8012-2 Hitachi EUB-5500 MAP WB8002-A Hitachi EUB-5500 Control

China Hitachi Noblus Image Missing Ultrasound Machine Repair EUB-5500 MAP-A WU8012-2 for sale

Hitachi Noblus Image Missing Ultrasound Machine Repair EUB-5500 MAP-A WU8012-2

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Hitachi Noblus Image Missing Ultrasound Machine Repair 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Image missing Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related Hitachi that we can offer: Brand Compatible System Description Hitachi EUB-5500 CW Doppler board EZU-ST5 Hitachi EUB-5500 MAP-A WU8012-2 Hitachi EUB-5500 MAP WB8002-A Hitachi EUB-5500 Control Panel KB319385

China Toshiba Aplio 500 Freeze Images Automatically Ultrasound Repair Service Replace Control Panel for sale Video

Toshiba Aplio 500 Freeze Images Automatically Ultrasound Repair Service Replace Control Panel

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Toshiba Aplio 300 Freeze Images Automatically Ultrasound Repair Service Replace Control Panel 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: Freeze Images Automatically Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range. Other ultrasound parts related to Toshiba that we can offer: Brand Compatible System Description Toshiba Famio 5 (SSA-510A) TFT board BSM31-5629 Toshiba Famio 8 SSA-530A PCB board I/O

China HD11 Ultrasound Imaging Equipment Repair  453561197144 for sale Video

HD11 Ultrasound Imaging Equipment Repair 453561197144

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

HD11 System Reports Error The parts with high failure rate&available in stock of this machine: 1.T/R board(453561448371) 2.SP Board(453561210154/453561343282) 3.ACB Board acquisition control board(453561197145/453561197144) 4.AIM board(453561197306) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson E6

China HD15 Transducer Sonography Repair 453561197145 for sale Video

HD15 Transducer Sonography Repair 453561197145

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

HD15 System Reports Error The parts with high failure rate&available in stock of this machine: 1.T/R board(453561448371) 2.SP Board(453561210154/453561343282) 3.ACB Board acquisition control board(453561197145/453561197144) 4.AIM board(453561197306) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson E6

China Abnormal Image Ultrasound Machine Repair Service Mindray DC-3 for sale

Abnormal Image Ultrasound Machine Repair Service Mindray DC-3

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

Mindray DC-3 Abnormal Image Ultrasound Machine Repair Service ​Model: Mindray DC-3 Mindray DC-3 image loss is abnormal. All probes are faulty after switching, and it is judged that it is caused by the fault of the transmitting board or the receiving board. Maintenance result: After replacing the transmitting board, the image of the machine probe is normal. Common Probe failure 1. Lens: Acoustic lens damage or bulge 2. Cable: the cable is damaged and the shell is cracked 3.

China Mindray DC-8 Blood Flow Button Fails And Machine Reports A Keyboard Card Key Alarm for sale

Mindray DC-8 Blood Flow Button Fails And Machine Reports A Keyboard Card Key Alarm

Price: Negotiable
MOQ: 1
Delivery Time: 1-3 work days

Mindray DC-8 The Blood Flow Button Fails And The Machine Reports A Keyboard Card Key Alarm ​Model: Mindray DC-8 Mindray DC-8 The Blood Flow Button Fails And The Machine Reports A Keyboard Card Key Alarm Repair results: After replacing the control panel, the machine returned to normal use. Common Probe failure 1. Lens: Acoustic lens damage or bulge 2. Cable: the cable is damaged and the shell is cracked 3. Image attenuation: aging attenuation 4. Shadow: dark vertical line 5.

China IE33 Ultrasound Machine Repair Small Parts Probe Image Loss for sale

IE33 Ultrasound Machine Repair Small Parts Probe Image Loss

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

IE33 Ultrasound Machine Repair Machine Small Parts Probe Image Loss 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: During use, the image on one side of the probe becomes dark and missing, and the image on the other probe is normal, which is judged to be a fault of the probe. Various GE/Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range. Other ultrasound parts related that we can offer: Brand System Description

China Ultrasound Image Without Echo Ultrasound Machine Repair Replace RFM Board for sale

Ultrasound Image Without Echo Ultrasound Machine Repair Replace RFM Board

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

GE Voluson E10 Ultrasound Image Without Echo Ultrasound Machine Repair Replace RFM Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: All probe switching is echo-free, consider RFM or power failure after RFM Replacement, the machine is back to work normally. Various GE/Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200

China HD7 Ultrasound Machine Repair DICOM Error Reported 453561184013 for sale

HD7 Ultrasound Machine Repair DICOM Error Reported 453561184013

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

HD7 Ultrasound Machine Repair DICOM Error Reported During Use 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: Philips HD7 reports DICOM errors during use, replaces the system, and troubleshoots Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range. Other ultrasound parts related to that we can offer: System Description Envisor control panel 453561184013 Envisor TR board M2540-20240 453561448371 Envisor RX/TX

China EPIQ 5 Ultrasound Machine Repair Abnormal Image Snowflake Interference Replace ACQ for sale

EPIQ 5 Ultrasound Machine Repair Abnormal Image Snowflake Interference Replace ACQ

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Philips EPIQ 5 Ultrasound Machine Repair Abnormal Image Snowflake Interference Replace ACQ 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:All probe images have snowflake interference, eliminate the probe problem, self-check CB error, and judge ACQ fault. Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range. Other ultrasound parts related to GE that we can offer: System Description Envisor control panel

China IU22 Ultrasound Machine Repair Machine Powers Off Immediately After Plugging for sale

IU22 Ultrasound Machine Repair Machine Powers Off Immediately After Plugging

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

IU22 Ultrasound Machine Repair Machine Powers Off Immediately After Plugging 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Machine Powers Off Immediately After Plugging Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related that we can offer: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540-20240 453561448371

China medical Ultrasound Machine Repair Samsung WS80A Automatically Power Off When Booting Up And Unable To Boot Up Normally for sale

medical Ultrasound Machine Repair Samsung WS80A Automatically Power Off When Booting Up And Unable To Boot Up Normally

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Samsung WS80A Automatically Power Off When Booting Up And Unable To Boot Up Normally 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Automatically Power Off When Booting Up And Unable To Boot Up Normally Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Knowledge point Importance of maintaining ultrasound machine Paying attention to preventive maintenance is the basic requirement of medical