China Modern Hitachi Aloka Alpha 6 Ultrasound Machine Repair Instrument Medical Surgical for sale Video

Modern Hitachi Aloka Alpha 6 Ultrasound Machine Repair Instrument Medical Surgical

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

Hitachi Aloka Alpha 6 System Reports Error The parts with high failure rate&available in stock of this machine: 1.Mainboard(EP493700DD) 2.CW( EP555700) 3.RX Beam Former(EP555501AA) 4.CPU mainboard(EP537000/EP563000) 5.TX/RX(EP555300) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson E6/Voluson E8 RSR

China Hitachi Aloka Alpha 10 Abdominal Ultrasound Machine Repair For Obstetrics for sale Video

Hitachi Aloka Alpha 10 Abdominal Ultrasound Machine Repair For Obstetrics

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

Hitachi Aloka Alpha 10 System Reports Error Faults phenomenon The ALOKA &α10 machine abdomen probe has no echo, the superficial probe has only a weak echo, and the heart probe has a normal echo. The parts with high failure rate&available in stock of this machine:mainboard, CW, RX Beam Former, CPU mainboard, TX/RX. Failure analysis Since the heart probe has a normal echo, it is necessary to first eliminate the fault caused by the probe itself, and replace the other abdominal

China 3d Ultrasound Machine Repair  IU22 Cow Scanning Equipment Repair for sale Video

3d Ultrasound Machine Repair IU22 Cow Scanning Equipment Repair

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

IU22 Cow Scanning Equipment Repair IU22 System Reports Error Fault phenomenon The screen of the IU22 ultrasound device stays on the scroll bar interface when it is turned on. After 30 s, a dialog box error code 518 appears. You can choose to enter the settings or directly shut down the dialog box below, but you cannot enter the system operation interface. Restarting the device cannot be solved. Fault analysis and Troubleshooting Enter the setting

China 453561419431  IE33 Ultrasound Machine Repair Diagnostic System for sale Video

453561419431 IE33 Ultrasound Machine Repair Diagnostic System

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

IE33 Ultrasound Diagnostic System Repair IE33 System Reports Error The parts with high failure rate&available in stock of this machine: 1.CB Board (Channel Board)(453561156011/453561156012/453561156014/453561164271/453561287451/453561303902) 2.AIM Board(453561210241/453561210243/453561210321/453561160675/453561160672/453561210243) 3.Front End Controller(453561278261/453561278266/453561464291/453561153751) 4.EMB Mainboard (excelsior motherboard)(453561419431

China IU22 Probe Frequency Ultrasound Machine Repair Diagnostic Supplies for sale Video

IU22 Probe Frequency Ultrasound Machine Repair Diagnostic Supplies

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

IU22 Probe Frequency Ultrasound Repair IU22 System Reports Error Fault phenomenon After pressing the power button, the screen of the IU22 ultrasound device does not display an image. Fault analysis and Troubleshooting The device's non-display failure is roughly divided into two categories: the display or the display cable is faulty; the computer host fails to start normally. After the device is turned on, you can feel the vibration of the host when it

China EPIQ5 Ultrasound Equipment Repair Ultrasonic Diagnostic Instrument for sale Video

EPIQ5 Ultrasound Equipment Repair Ultrasonic Diagnostic Instrument

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

EPIQ5 Ultrasound Machine Maintenance EPIQ5 System Reports Error The parts with high failure rate&available in stock of this machine: ACQ Acquisition Module board(453561734844 REV A /453561704246/453561734845/453561734843) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson E6/Voluson E8

China CX50 Ultrasound Machine Repair Common Surgical Instruments Maintenance for sale Video

CX50 Ultrasound Machine Repair Common Surgical Instruments Maintenance

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

CX50 System Reports Error Failure phenomenon The machine has a blue screen when it is turned on and cannot be started normally. Failure analysis On-site consultation using the doctor learned that the machine did not make any changes to the machine hardware and software before the blue screen appeared, the blue screen code is 0x000000ED, the code generally points to the hard disk failure. After the machine is disassembled, the hard disk of the machine is detected. It

China Ray Detector Ultrasound Probe Repair Affiniti 50 Sonography Machine Maintenance for sale Video

Ray Detector Ultrasound Probe Repair Affiniti 50 Sonography Machine Maintenance

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

Affiniti 50 Latest Sonography Machine Maintenance Affinitti 50 System Reports Error The parts with high failure rate&available in stock of this machine: ACQ Acquisition Module board(4535161610416/4535161610426) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson E6/Voluson E8 RSR

China Affiniti 70 Colour Doppler Machine Repair Hospital Equipments for sale Video

Affiniti 70 Colour Doppler Machine Repair Hospital Equipments

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

Affiniti 70 Colour Doppler Machine Maintenance Affinitti 70 System Reports Error The parts with high failure rate&available in stock of this machine: ACQ Acquisition Module board(4535161610416/4535161610426) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson E6/Voluson E8 RSR KTI301394-2

China Toshiba Aplio 300 Ultrasound Transducer Repair PM30-38696 for sale Video

Toshiba Aplio 300 Ultrasound Transducer Repair PM30-38696

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

Toshiba Aplio 300 Ultrasound Transducer Repair Toshiba Aplio 300 System Reports Error The parts with high failure rate&available in stock of this machine: 1.Motherboard (BV board)(PM30-38696) 2.TX Board (PM30-38691) 3.RX Board(PM30-39444) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson E6/Voluson E8

China Toshiba Xario 100 Medical Monitoring Equipment Repair 60 Days Warranty for sale Video

Toshiba Xario 100 Medical Monitoring Equipment Repair 60 Days Warranty

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

Toshiba Xario 100 Medical Monitoring Equipment Repair Toshiba Xario 100 System Reports Error The parts with high failure rate&available in stock of this machine: 1.TX(PM30-32732-1) 2.RX(PM30-32733-1) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson E6/Voluson E8 RSR KTI301394-2/KTI196357 GE Voluson E6

China Toshiba Xario 200 Ultrasound Machine Repair Personal Sonogram for sale Video

Toshiba Xario 200 Ultrasound Machine Repair Personal Sonogram

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

Toshiba Xario 200 Personal Sonogram Machine Repair Toshiba Xario 200 System Reports Error The parts with high failure rate&available in stock of this machine: 1.TX(PM30-32732-1) 2.RX(PM30-32733-1) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson E6/Voluson E8 RSR KTI301394-2/KTI196357 GE Voluson E6

9 10 11 12 13