12V 100AH Lead Acid Battery Rechargeable Renewable Energy Storage Batteries
12V 100AH Lead Acid Battery Rechargeable Renewable Energy Storage Batteries
| Nominal Voltage | 12V | |
| Nominal Capacity (C20) | 100Ah (10.8V,at 25℃) | |
| Dimension | Length | 329mm |
| Width | 174mm | |
| Height | 223mm | |
| Total Height | 223mm | |
| Weight | Approx. 32.50 kg | |
| Terminal | Cable of φ6mm | |
| Internal Resistance | Approx. 6.5 mΩ (25℃) | |
| Max Short-duration Discharge Current | 2000A(25℃) | |
Description:
● Designed life is 5~8 years (20℃);
● High tin alloy, imported colloid electrolyte and special lead plaster;
● Wide temperature scope of application (-30~45℃);
● Best temperature of application (20±5℃);
● No leaking, safe and reliable;
● Standing or lying down for using, convenient to transport and install;
● Good performance on long-term insufficient charge and frequency discharge;
● The battery with unique waterproof technical treatment cables ensure the stable operation of solar street lamp products.
● Low self-discharge rate.
Applications:
● Energy Storage
● Automotive
● Telecommunication
● Banks & Financial Centre
● Hospital& Testing Laboratories
● Emergency Power System
● Alarm & Security system
● High Power Backup Supply
● Power systems
STORAGE
● Batteries should be stored in dry and clean warehouse which has good air exchange system. Batteries should avoid direct sunlight. Batteries should not be near to heat (such as radiator, the distance should more than1m). Batteries should avoid any toxic gas and organic solvent.
● When the ambient temperature is less than 25℃, the longest storage life is 6 months.
● Batteries should be recharged within the storage life or before using.
Charging methods: maximum charging current 8A, constant voltage 2.45±0.05V/cell (25℃);
Charging time: 15~20h; Temperature compensation coefficient: -5mV/℃/cell.
TECHNICAL FEATURES:
• Sealed Construction
The unique construction and use waterproof battery cable to offer reliable guarantee for stable operation of solar street lamp products.
• Electrolyte Suspension System
All batteries utilize an electrolyte suspension system consisting of a high porosity, glass fiber material which in conjunction with plates, totally absorb and contain the electrolyte.
• Gas Recombination
CGB batteries incorporate a built-in design that controls gas generation and induces recombination of more than 99% of gases generated during float or cyclic usage.
• Maintenance Free Operation
There is no need to check specific gravity of the electrolyte or add water to batteries during float service life. In fact, there is no provision for this type of maintenance.
• Low Pressure Valve Regulated System..
All batteries are equipped with safety release valves, designed to operate between 1.5 and 6 psi (10-40kPa) and automatically reseal. Hence, there is never an excessive accumulation of gas within the battery.
• Heavy Duty Grids
Heavy duty lead calcium tin alloy grids provide an extra margin of performance and service life in either float or cyclic applications.
• Self Discharge - Shelf Life
The self discharge rate at room temperature is approximately 3% of rated capacity per month.
• Operating Temperature
CGB Batteries may be operated over a broad range of ambient temperatures.
• Deep Discharge Recovery
The batteries recover their capacities even after repeated deep discharges.
Caution
(1) The valve regulated sealed lead acid battery is maintenance free and without acid adding, any top cover opening is forbidden during use.
(2)Battery should be charged once every 6 months after leaving the factory.
(3)Checking the battery appearance before using, and avoid strong vibration or mechanical damage.
(4)Recommend recycling using temperature 25℃ ± 5% , the battery is strictly prohibited get wet in the rain and soaking.
(5)Battery installation and removal should be uniform stress, stress at the shell should be part of the battery, avoid damage the terminal.
(6)If you need batteries in parallel, do not exceed three parallel.
(7) When used in multiple circuits, it must be according to battery marks "+", "-" in order of priority and space cannot be less than 15mm.
(8)Before you connecting with device, make it disconnected, then connect battery positive to the devices positive, negative connected to negative terminal, and fix the cable.
Services:
CGB has an extensive range of services to ensure that you get the best performance from your battery and charger investment. From design and installation to maintenance and recycling, you can count on the expertise of our engineers and service technicians.
• Monitor, control and eliminate, where possible, all environmental emissions, discharges and waste generated by our operations.
• Develop products that will have a minimum effect on our environment.
• Work with organizations to develop equitable and realistic laws, regulations and standards to protect public health and the environment.
FAQ
Q: What should I notice while I'm using the battery?
A: Before you use it, please ensure it's full charging.
Q: When the battery is not using for a long time, what should I do?
A: You should charge it full at first.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.