Lightweight Sealed Lead Acid Rechargeable Battery 12V 180AH For Electric Power

Price Negotiable
Price: Negotiation
MOQ: 50 pcs
Delivery Time: 30 days
Brand: CGB
Product Description

Lightweight Sealed Lead Acid Rechargeable Battery 12V 180AH For Electric Power

 

Specifications:

 

Nominal Voltage 12V Capacity C10 180Ah (10.5V, at 25℃)
Nominal Capacity (C10) 180Ah (10.5V,at 25℃) C5 144Ah (10.5V, at 25℃)
Dimension Length 560mm C3 135Ah (10.5V, at 25℃)
Width 125mm C1 99Ah (10.2V, at 25℃)
Height 316mm Internal Resistance Approx. 3.6 mΩ (25℃)
Total Height 316mm Max Short-duration Discharge Current 3600A(25℃)
Weight Approx. 54.50kg Terminal RT-62

 

 

Description:

● Designed life for floating charge is 10 years (20℃);

● Special polybasic alloys material of grid, strong

corrosion-resisting character, special formula of

lead paste, advanced plate curing technology,

long service life;

● AGM valve regulated sealing technology;

● High strength ABS material for container & lid;

● Wide temperature scope of application (-15~45℃);

● Best temperature of application (20±5℃);

● The shape is long and narrow, positive and

negative terminals are at the same side, it is very

convenient to install, monitor and maintain;

● Special protective cover for post, it is great to avoid

short circuit between positive and negative terminals;

● Special sealing technology of post and superior

sealing glue for post to make sure that there is no leaking on terminals;

● The acid filter and anti-explosion design can make sure the low

remitting of acid mist, ensure the safe and reliable application.

 

Applications:

● UPS & EPS System

● Telecommunication

● Banks & Financial Centre

● Hospital& Testing Laboratories

● Telecommunication

● Solar & Wind Energy System

 

TECHNICAL FEATURES:

• Sealed Construction

The unique construction and sealing techniques ensure no electrolyte leakage from case or terminals.

 

• Electrolyte Suspension System

All batteries utilize an electrolyte suspension system consisting of a high porosity, glass fiber material which in conjunction with plates, totally absorb and contain the electrolyte.

 

• Gas Recombination

CGB batteries incorporate a built-in design that controls gas generation and induces recombination of more than 99% of gases generated during float or cyclic usage.

 

• Maintenance Free Operation

There is no need to check specific gravity of the electrolyte or add water to batteries during float service life. In fact, there is no provision for this type of maintenance.

 

• Low Pressure Valve Regulated System..

All batteries are equipped with safety release valves, designed to operate between 1.5 and 6 psi (10-40kPa) and automatically reseal. Hence, there is never an excessive accumulation of gas within the battery.

 

• Heavy Duty Grids

Heavy duty lead calcium tin alloy grids provide an extra margin of performance and service life in either float or cyclic applications.

 

• Cyclic Service Life

More than 600 discharge/recharge cycles can be realized from CGB CB and HR batteries, dependent on the average depth of discharge.

 

• Float Service Life

SE and CB, HR Series batteries have an expected life span of 3 to 5 years in float service applications.

 

• Self Discharge - Shelf Life

The self discharge rate at room temperature is approximately 3% of rated capacity per month.

 

• Operating Temperature

CGB Batteries may be operated over a broad range of ambient temperatures.

 

• Terminals

The batteries are manufactured using a range of terminals which vary in size and type. Please refer to details as shown

 

 

CHARGE

Using Mode Charging Voltage Temperature Compensation Max Charging Current
Standby Use 2.275±0.025V/cell (25℃) -3.3mV/℃/cell 45A
Cyclic Use 2.45±0.05V/cell (25℃) -5mV/℃/cell

 

 

Caution

1) The valve regulated sealed lead acid battery is maintenance free and without acid adding, any top cover opening is forbidden during use.
(2) Battery should be charged once every 6 months after leaving the factory.
(3)Checking the battery appearance before using, and avoid strong vibration or mechanical damage.
(4)Recommend recycling using temperature 25℃ ± 5% , the battery is strictly prohibited get wet in the rain and soaking.
(5)Battery installation and removal should be uniform stress, stress at the shell should be part of the battery, avoid damage the terminal.
(6)If you need batteries in parallel, do not exceed three parallel.
(7) Battery when used in multiple circuits, it must be according to battery marks "+", "-" in order of priority and space cannot be less than 15mm.
(8)Before you connecting with device, make it disconnected, then connect 6V200Ah battery positive to the devices positive, negative connected to negative terminal, and fix the cable.
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Wuhan Changguang Battery Co., Ltd
Location Wuhan Economic & Technology Development Zone, Wuhan, 430056 China
Contact Person Song_Gao

Request A Quote

Please check your email address.
Your message must be at least 20 characters.