Energy Storage Sealed Lead Acid Rechargeable Battery 12V Deep Cycle

 

 

Specifications:

Nominal Voltage 12V
Nominal Capacity (C20) 150Ah (10.8V,at 25℃)
Dimension Length 483mm
Width 170mm
Height 241mm
Total Height 241mm
Weight Approx. 46.30 kg
Terminal FP-31/RT-32
Internal Resistance Approx. 4.5 mΩ (25℃)
Max Short-duration Discharge Current 3000A(25℃)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Description:

● Designed life is 5~8 years (20℃);

● High tin alloy, imported colloid electrolyte and special lead plaster;

● Wide temperature scope of application (-30~45℃);

● Best temperature of application (20±5℃);

● No leaking, safe and reliable;

● Standing or lying down for using, convenient to transport and install;

● Good performance on long-term insufficient charge and frequency discharge;

● The battery with unique waterproof technical treatment cables ensure the stable operation of solar street lamp products.

● Low self-discharge rate.

 

Applications:

● Energy Storage

● Automotive

● Telecommunication

● Banks & Financial Centre

● Hospital& Testing Laboratories

● Emergency Power System

● Alarm & Security system

● High Power Backup Supply

● Power systems

 

STORAGE

● Batteries should be stored in dry and clean warehouse which has good air exchange system. Batteries should avoid direct sunlight. Batteries should not be near to heat (such as radiator, the distance should more than1m). Batteries should avoid any toxic gas and organic solvent.

● When the ambient temperature is less than 25℃, the longest storage life is 6 months. If ambient temperature is higher, the longest storage life varies as specified in below chart.

Storage Temperature (℃) ≤25 26~33 34~40
Storage Time (Month) 6 3 1

 

 

 

 

● Batteries should be recharged within the storage life or before using.

Charging methods: maximum charging current 8A, constant voltage 2.45±0.05V/cell (25℃);

Charging time: 15~20h; Temperature compensation coefficient: -5mV/℃/cell.

 

TECHNICAL FEATURES:

• Sealed Construction

The unique construction and use waterproof battery cable to offer reliable guarantee for stable operation of solar street lamp products.

 

• Electrolyte Suspension System

All batteries utilize an electrolyte suspension system consisting of a high porosity, glass fiber material which in conjunction with plates, totally absorb and contain the electrolyte.

 

• Gas Recombination

CGB batteries incorporate a built-in design that controls gas generation and induces recombination of more than 99% of gases generated during float or cyclic usage.

 

• Maintenance Free Operation

There is no need to check specific gravity of the electrolyte or add water to batteries during float service life. In fact, there is no provision for this type of maintenance.

 

• Low Pressure Valve Regulated System..

All batteries are equipped with safety release valves, designed to operate between 1.5 and 6 psi (10-40kPa) and automatically reseal. Hence, there is never an excessive accumulation of gas within the battery.

 

• Heavy Duty Grids

Heavy duty lead calcium tin alloy grids provide an extra margin of performance and service life in either float or cyclic applications.

 

• Self Discharge - Shelf Life

The self discharge rate at room temperature is approximately 3% of rated capacity per month.

 

• Operating Temperature

CGB Batteries may be operated over a broad range of ambient temperatures.

 

• Deep Discharge Recovery

The batteries recover their capacities even after repeated deep discharges.

 

Precautions:

• Always handle batteries with care.

• Always store upright.

• Always charge in a well ventilated place.

• Always wear eye protection when handling batteries.

• Wear protective clothing if there is any rick of acid splashing.

Danger

• Do not use at the places near fire. Hydrogen gas generated from battery may cause fire and explosion.

• This 12v battery is only for starting engine. Do not apply for other uses.

• Keep out of the reach of children or the personnel who do not understand the manual. It may cause blindness or severe burn.

• When using the battery, wear safety glasses and rubber gloves.Sulfuric acid may cause blindness or severe burn.

 

Warning

• Replacement of battery shall be performed as per following order. If failed, it may cause fire and explosion. Remove cable from negative terminal first.Connect cable to negative terminal last.

• When connect cable to battery, make sure not to get changed post of +and -. It may cause the damage of electronic components or fire.

• When ueing the battery ,handle with care,sulfuric acid may cause blindness or severe burn.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Wuhan Changguang Battery Co., Ltd
Location Wuhan Economic & Technology Development Zone, Wuhan, 430056 China
Contact Person Song_Gao

Request A Quote

Please check your email address.
Your message must be at least 20 characters.