Wuhan Changguang Battery Co., Ltd
                                                                                                           
Member Supplier
33 Years
Since 1993
Menu

CB640 Alarm Lighting Backup 6v 10ah Battery Non Spillable Maintenance Free

Price Negotiable
Price: Negotiation
MOQ: 300 pcs
Delivery Time: 30 days
Brand: CGB
Product Description

 

 

CB640 Alarm Lighting Backup 6v 10ah Battery Non Spillable Maintenance Free

 

 

Description

 

 

Sealed Construction

 

The unique construction and sealing techniques of the battery guarantee leak

 

proof operation in any position with no adverse effect to capacity or service life.

 

 

Electrolyte Suspension System

 

All batteries utilize an electrolyte suspension system consisting of a high

 

porosity, glass fiber material which in conjunction with plates, totally absorb and

 

contain the electrolyte.

 

 

Gas Recombination

 

CGB batteries incorporate a built-in design that controls gas generation and

 

induces recombination of more than 99% of gases generated during float or

 

cyclic usage.

 

 

Maintenance Free Operation

 

Due to the perfectly sealed construction and the recombination of gasses within

 

the cells, the battery is almost maintenance free.

 

 

Low Pressure Valve Regulated System..

 

All batteries are equipped with safety release valves, designed to operate

 

between 1.5 and 6 psi (10-40kPa) and automatically reseal. Hence, there is

 

never an excessive accumulation of gas within the battery.

 

 

Heavy Duty Grids

 

Heavy duty lead calcium tin alloy grids provide an extra margin of performance

 

and service life in either float or cyclic applications.

 

 

Cyclic Service Life

 

More than 600 discharge/recharge cycles can be realized from CGB CB and HR

 

batteries, dependent on the average depth of discharge.

 

 

Float Service Life

 

SE and CB, HR Series batteries have an expected life span of 3 to 5 years in

 

float service applications.

 

 

Self Discharge - Shelf Life

 

The self discharge rate at room temperature is approximately 3% of rated

 

capacity per month.

 

 

Operating Temperature

 

CGB Batteries may be operated over a broad range of ambient temperatures.

 

 

Deep Discharge Recovery

 

The batteries recover their capacities even after repeated deep discharges

 

 

 

 

Specifications

 

Nominal Voltage

 

6V

Nominal Capacity (C20)

 

10Ah (5.25V,at 25℃)
Dimension

Length

 

151mm

Width

 

50mm

Height

 

95mm

Total Height

 

101mm

Weight

 

Approx. 1.73kg

Terminal

 

FO-02/FO-03

Internal Resistance

 

Approx. 10 mΩ (25℃)

Max Charging Current

 

300A

 

 

 

Feature

 

 

Designed life for floating charge is 2~3 years (20℃);

 

 

Gas Recombination;

 

 

Wide temperature scope of application (-15~45℃);

 

 

Best temperature of application (20±5℃);

 

 

No leaking, safe and reliable;

 

 

Standing or lying down for using, convenient to transport and install;

 

 

High sealed reaction efficiency, little loss of water, no need to add distilled

 

water or electrolyte, simple to use and maintain

 

 

Application specific design.

 

 

 

Applications:

 

 

Alarm & Security system

 

 

Emergency Power Systerm

 

 

Fire-safety Emergency System,

 

 

Banks & Financial Centre

 

 

Hospital& Testing Laboratories

 

 

Telecommunication

 

 

Charge

 

Using Mode Charging Voltage Temperature Compensation Max Charging Current
Standby Use 2.275±0.025V/cell (25℃) -3.3mV/℃/cell 3.0A
Cyclic Use 2.45±0.05V/cell (25℃) -5mV/℃/cell

 

 

 

 

STORAGE

 

 

Batteries should be stored in dry and clean warehouse which has good air

 

exchange system. Batteries should avoid direct sunlight. Batteries should not

 

be near to heat (such as radiator, the distance should more than 1m). Batteries

 

should avoid any toxic gas and organic solvent.

 

 

When the ambient temperature is less than 25℃, the longest storage life is 6

 

months. If ambient temperature is higher, the longest storage life varies as

 

specified in below chart.

 

 

 

Storage Temperature (℃)

 

≤25

 

 

26~33

 

 

34~40

 

 

Storage Time (Month)

 

6

 

 

3

 

 

1

 

 

 

                                                                                                 

 

Batteries should be recharged within the storage life or before using.

 

Charging methods: maximum charging current 3.0A, constant voltage

 

2.45±0.05V/cell (25℃);

 

 

Charging time: 15~20h; Temperature compensation coefficient: -5mV/℃/cell.

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Wuhan Changguang Battery Co., Ltd
Location Wuhan Economic & Technology Development Zone, Wuhan, 430056 China
Contact Person Song_Gao

Request A Quote

Please check your email address.
Your message must be at least 20 characters.