Standard:Conforms to IEC 60335-2-6 clause 22.111, etc.
Application:It is used to check whether flammable gases are emitted from the vents during the cleaning process of pyrolytic self-cleaning ovens and whether there is an ignition hazard.
Technical Parameters:
1. Spark length: about 3mm;
2. Energy of each spark: at least 0.5J;
3. Spark generation mode: bipolar output;
4. Peak voltage: ±7kv;
5. Current: 40mA; 20kHz;
6. Ignition distance: 2-5mm adjustable.