IEC61386-1:2017 Clause 10.3 Low Temperature Impact Test Apparatus

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 30 days
Brand: Sinuo
Product Description

IEC61386-1:2017 Clause 10.3 Low Temperature Impact Test Apparatus



Product information:


Applicable Standards: IEC61386-1:2017clause 10.3

 

Specimens & Scope: Suitable for metal, non-metallic and composite conduits used to protect and manage insulated wires and/or cables for electrical or communication systems up to AC 1000 V and/or DC 1500 V.

 

Test Purpose: To evaluate the mechanical impact resistance of conduits after low-temperature conditioning.

 

Test Principle: The specimen is impacted by a falling hammer released freely from a specified height.

 

Structure & Features:

This device is used together with a low-temperature chamber.

The apparatus should be placed on a solid horizontal surface.

Before testing, the specimen shall be conditioned in a suitable low-temperature chamber, and the impact test shall be completed within 10 seconds after removal from the chamber.

 

Technical parameters:


No.

Item

parameters

1

Model

SN2127A

2

Test stations

Three stations

3

Specimen length

200 ± 5 mm

4

Drop hammer masses

0.5 kg, 1.0 kg, 2.0 kg, 6.8 kg (three pieces each), tolerance +1  0%

5

Drop height

100 mm, 300 mm, tolerance ±1%, adjustable

 

6

Steel anvil

Ø20 mm, bottom arc radius R300, 100 g

7

Release method

Manual, latch-type mechanical release

8

Structure figure


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Sinuo Testing Equipment Co. , Limited
Location Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Contact Person Zoe Zou

Request A Quote

Please check your email address.
Your message must be at least 20 characters.