IEC60335-1 Clause 8.1.4 Anti - Shock Probe Experiment Device

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 15 Days
Brand: Sinuo
Product Description

 

IEC60335-1 Clause 8.1.4 Anti - Shock Probe Experiment Device

 

Product Information:

This anti-shock probe experiment device is designed and manufactured meet the requirements of the standard of IEC60335-1 Clause 8.1.4, IEC 60065:2014 clause 9.1.1.2, and etc. It is used together with the testing probe for checking whether the probe can contact the live parts of electrical appliance, to verify the protection of persons against access to hazardous parts inside the enclosure.
For the two output electrodes, one of electrodes is connected with the energized part of the electrical appliance and the other electrodes is connected with the input terminal of the probe used. Then turn on the POWER switch of the device, and use the probe to touch the parts that maybe electrified. If the alarm of the equipment sounds, it is proved that the testing part is electrified. Then press the button of reset and cut off the circuit.

 

Technical Parameters:

Applied standard IEC60335-1
Applied clause Clause 8.1.4
Working voltage AC 220V±10%, 50HZ±1%
Electrode output the testing voltage AC40-50V
Working temperature 0-40
Relative humidity: ≤80%
Environment No shaking and no corrosive gas
Operation Steps:
1. Connect one of the two output electrodes with live part of electrical appliance, connect another with the test finger probe.

2. Then turn on the POWER switch, use the test finger probe to touch other parts of the electrical appliance.

3. If test finger probe touches a live part, electrical contact indicator alarm, buzzer sound, indicating the touched part is a live part, or it is not.

4. Press RESET button to stop alarm and cut off the power supply.

 

Notice:

1. Check whether connecting wires are conductive.

2. Please do not place two connecting wires on same metal part, so as to avoid the formation of the circuit and error alarm.

3. Be careful of electric shock.

 

Details:

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Sinuo Testing Equipment Co. , Limited
Location Room 101, 1st Floor, No. 6, Third Street, Pingshan Industrial Zone 511495, Shibi Street, Panyu District, Guangzhou, China
Contact Person Zoe Zou

Request A Quote

Please check your email address.
Your message must be at least 20 characters.