Leeb810A A type Shore Hardness Tester For Thermoplastics Hard Resins

Price Negotiable
Price: Based on quantity
MOQ: 1 Set
Delivery Time: In 7-10 work days
Brand: LEEB
Product Description

Leeb810A A type Shore Hardness Tester For Thermoplastics Hard Resins

 

Integration Digital High Precision Shore A Hardness Tester & Shore Durometer With 0.1HA Resolution

 

 

Function & Feature:
 
1, Leeb810A is the Shore A type digital hardness tester for the rubber.
2, It applies to plastic (such as films, medical equipment, etc.), synthetic rubber
     (such as seals, tires, rubber roller, wire and cable, etc.), and other related chemical products.
3, Maximum locking storage, automatic calculation of the mean and under-voltage alarm.
4, Integrating measurement device and data processing
5, connected to the PC by RS232 interface
 

 

Application

 

Mainly used to determine the hardness of hard plastics and hard rubbers, such as: thermoplastics, hard resins, floor materials, bowling balls, etc., especially suitable for on-site hardness measurement of rubber and plastic products

 

 

Technical Parameters

 

Technical Parameters
Model No.
Leeb810A
Measuring range
0~100HA
Resolution
0.1HA
Accuracy
≤±1HA (At the range of 20 to 90HA)
Size of pressure
needle head
Φ0.79mm
Pressure needle  
stroke
2.5mm
Operating
temperature
0℃~40℃
Dimensions
173×56×42mm
Power supply
3×1.5V Button batteries
Weight
233g

 

 

 

Calibration:


1, Zero calibration: After turning on, the hardness tester is in working state, and the length of the pressing needle is extended at this time, the screen show zero for hardness value.
2, Non-zero calibration:
Please make the bottom surface of the hardness tester and the flat glass plate contact fully , so that the extended length of the pressure pin is zero. At this time, the screen hardness value should be 100.

Note: the needle tip and the glass plate should be strictly avoided strong contact and impact during calibration in order to protect the conical needle tip of the hardness tester, otherwise it is easy to damage the hardness tester needle, and the hardness tester can not work properly.

 

 

Maintenance:


1, The hardness tester should avoid impact and heavy pressure, and should not be placed in the environment of strong magnetic field, humidity or oil stains;
2, If the hardness tester is not used for a long time, three button batteries should be taken out and stored properly;

 

 

Packing box: Equipment Box

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Chongqing Leeb Instrument Co.,Ltd
Location High&New Technology Industrial Park, Yubei District, Chongqing, China
Contact Person Leeb Team

Request A Quote

Please check your email address.
Your message must be at least 20 characters.