Hitachi Aloka Alpha 7 EP555500 Channel Board Repair Resolution
Hitachi Aloka Alpha 7 EP555500 Channel Board Repair Resolution
1. Repair time: 2-4 days
2. Warranty: with 60 days after fixed
3. Part number: EP555500
4. Compatible with Alpha 7
Other ultrasound parts related to Aloka that we can offer:
| Brand | Model | Name | Part Number |
| Aloka | Alpha 6 | CPU mainboard | EP537000/EP563000 |
| Aloka | Alpha 6 | TX/RX | EP555300 |
| Aloka | Alpha 6/Alpha 7 | DOM | EP550000AA |
| Aloka | Alpha 7 | RX Beam Former /DBF1 | EP539100BB/EP539500DG/EP539501DG |
| Aloka | Alpha 7 | CPU mainboard | EP558900 |
| Aloka | Alpha 7 | TX BOARD | EP548300BB |
| Aloka | Alpha 10 | wave generator Transmitting Board | EP495000HH/EP495000HJ/EP495000FF |
| Aloka | Alpha 10 | High-voltage Board | EP541800 |
| Aloka | Alpha 10 | CPU mainboard | EP496000 |
Ultrasound Transducer Probe Which are Compatible with Alpha 7
| Brand | Machine | Model |
| ALoka | Alpha 7 | UST-9120 |
| ALoka | Alpha 8 | UST-9123 |
| ALoka | Alpha 9 | UST-9124 |
| ALoka | Alpha 10 | UST-9130 |
| ALoka | Alpha 11 | UST-9133 |
About Us
Rongtao Medical, one of the leading service companies in China, has sold over 10,000+ probes, 20,000+ medical parts and repaired 5,000+ machines in the worldwide from 2014. As a comprehensive medical device company, we provide a wide range of diagnostic ultrasound services and other associated items (endoscopy, patient Monitor and ventilator).
What information do customers need to offer in advance before repair?
1. The brand and model of the machine
2. Video or pictures of machine malfunction
3. Natural failure or artificial failure (for example, has it been repaired)
4. Accidental failure or frequent failure
5. All machines can do self-test, the same is true for HI VISION Avius and Preirus
6. Whether there is difference between connecting probe or not ( test selectively according to the machine fault, for example, if there is voltage error, the probe can be disconnected for test)
Knowledge point
Basic components of color Doppler ultrasound
1. Monitor (CRT/LCD)
2. Control panel (Touch screen, Numeric keyboard)
3. Front end (Probe interface board, FEC, AIM, CB)
4. Back end (Graphics card, DSC, Uavio, Mainboard )
5. Power supply(AC,PSA)
6. CD driver
7. Probe
Common failures of color Doppler ultrasound
1. Control panel failure
2. System software, application software failure
3. Back end failure
4. Power failure (Main power supply, Low-voltage power supply, High-voltage power supply)
5. Transducer Probe failure
6. Front-end failure (Interface board, Transmitter, Receiver, Control, VIDEO, Front-end connection)
7. Display failure (Display, Workstation, Touch screen)
8. Failure caused by external environment