Heating Cooling Immersion Coils
Heating & Cooling Immersion Coils for Metal Pickling & Finishing
| EXCHANGE AREA (Sq. ft.) |
NO. OF TUBES | WIDTH in./(mm) | LENGTH in./(mm) | PROTECH MODEL NUMBER | SHIP WT. Lbs./(kg) |
|---|---|---|---|---|---|
| 4.6 | 8 | 12.5 (318) | 24 (610) | *8G-24 | 13 (6) |
| 5.6 | 8 | 12.5 (318) | 30 (762) | *8G-30 | 14 (6.5) |
| 6.7 | 8 | 12.5 (318) | 36 (915) | *8G-36 | 15 (7) |
| 8.8 | 8 | 12.5 (318) | 48 (1219) | *8G-48 | 18 (8) |
| 10.9 | 8 | 12.5 (318) | 60 (1524) | *8G-60 | 20 (9) |
| 13.7 | 8 | 12.5 (318) | 72 (1829) | *8G-72 | 25 (11.5) |
| 15.1 | 8 | 12.5 (318) | 84 (2134) | *8G-84 | 30 (13.5) |
| 17.2 | 8 | 12.5 (318) | 96 (2438) | *8G-96 | 35 (16) |
| 19.2 | 8 | 12.5 (318) | 108 (2743) | *8G-108 | 38 (17) |
| 21.3 | 8 | 12.5 (318) | 120 (3048) | *8G-120 | 42 (19) |
| 23.4 | 8 | 12.5 (318) | 132 (3353) | *8G-132 | 45 (20.5) |
| 25.5 | 8 | 12.5 (318) | 144 (3658) | *8G-144 | 50 (22.5) |
| EXCHANGE AREA (Sq. ft.) |
NO. OF TUBES | WIDTH in./(mm) | LENGTH in./(mm) | PROTECH MODEL NUMBER | SHIP WT. Lbs./(kg) |
|---|---|---|---|---|---|
| 6.8 | 12 | 18.5 (470) | 24 (610) | *12G-24 | 15 (7) |
| 8.4 | 12 | 18.5 (470) | 30 (762) | *12G-30 | 18 (8) |
| 10.0 | 12 | 18.5 (470) | 36 (915) | *12G-36 | 22 (10) |
| 13.2 | 12 | 18.5 (470) | 48 (1219) | *12G-48 | 28 (13) |
| 16.3 | 12 | 18.5 (470) | 60 (1524) | *12G-60 | 35 (16) |
| 19.5 | 12 | 18.5 (470) | 72 (1829) | *12G-72 | 45 (20.5) |
| 22.6 | 12 | 18.5 (470) | 84 (2134) | *12G-84 | 50 (22.5) |
| 25.7 | 12 | 18.5 (470) | 96 (2438) | *12G-96 | 56 (25.5) |
| 28.9 | 12 | 18.5 (470) | 108 (2743) | *12G-108 | 62 (28) |
| 32.0 | 12 | 18.5 (470) | 120 (3048) | *12G-120 | 68 (31) |
| 35.2 | 12 | 18.5 (470) | 132 (3353) | *12G-132 | 75 (34) |
| 38.3 | 12 | 18.5 (470) | 144 (3658) | *12G-144 | 90 (41) |
| EXCHANGE AREA (Sq. ft.) |
NO. OF TUBES | WIDTH in./(mm) | LENGTH in./(mm) | PROTECH MODEL NUMBER | SHIP WT. Lbs./(kg) |
|---|---|---|---|---|---|
| 9.4 | 16 | 24.5 (622) | 24 (610) | *16G-24 | 20 (9) |
| 11.5 | 16 | 24.5 (622) | 30 (762) | *16G-30 | 25 (11.5) |
| 13.6 | 16 | 24.5 (622) | 36 (915) | *16G-36 | 29 (13) |
| 17.8 | 16 | 24.5 (622) | 48 (1219) | *16G-48 | 35 (15.5) |
| 22.0 | 16 | 24.5 (622) | 60 (1524) | *16G-60 | 43 (19.5) |
| 26.1 | 16 | 24.5 (622) | 72 (1829) | *16G-72 | 50 (22.5) |
| 30.3 | 16 | 24.5 (622) | 84 (2134) | *16G-84 | 62 (28) |
| 34.5 | 16 | 24.5 (622) | 96 (2438) | *16G-96 | 70 (32) |
| 38.7 | 16 | 24.5 (622) | 108 (2743) | *16G-108 | 80 (36) |
| 42.9 | 16 | 24.5 (622) | 120 (3048) | *16G-120 | 88 (40) |
| 47.1 | 16 | 24.5 (622) | 132 (3353) | *16G-132 | 97 (44) |
| 51.3 | 16 | 24.5 (622) | 144 (3658) | *16G-144 | 105 (47.5) |
| EXCHANGE AREA (Sq. ft.) |
NO. OF TUBES | WIDTH in./(mm) | LENGTH in./(mm) | PROTECH MODEL NUMBER | SHIP WT. Lbs./(kg) |
|---|---|---|---|---|---|
| 11.5 | 20 | 30.5 (775) | 24 (610) | *20G-24 | 23 (10.5) |
| 14.2 | 20 | 30.5 (775) | 30 (762) | *20G-30 | 28 (13) |
| 16.8 | 20 | 30.5 (775) | 36 (915) | *20G-36 | 34 (15.5) |
| 22.0 | 20 | 30.5 (775) | 48 (1219) | *20G-48 | 40 (18) |
| 27.2 | 20 | 30.5 (775) | 60 (1524) | *20G-60 | 48 (22) |
| 32.5 | 20 | 30.5 (775) | 72 (1829) | *20G-72 | 55 (25) |
| 37.7 | 20 | 30.5 (775) | 84 (2134) | *20G-84 | 68 (31) |
| 42.9 | 20 | 30.5 (775) | 96 (2438) | *20G-96 | 75 (34) |
| 48.2 | 20 | 30.5 (775) | 108 (2743) | *20G-108 | 87 (39.5) |
| 53.4 | 20 | 30.5 (775) | 120 (3048) | *20G-120 | 100 (45.5) |
| 58.6 | 20 | 30.5 (775) | 132 (3353) | *20G-132 | 115 (52) |
| 63.9 | 20 | 30.5 (775) | 144 (3658) | *20G-144 | 125 (57) |
| EXCHANGE AREA (Sq. ft.) |
NO. OF TUBES | WIDTH in./(mm) | LENGTH in./(mm) | PROTECH MODEL NUMBER | SHIP WT. Lbs./(kg) |
|---|---|---|---|---|---|
| 13.7 | 24 | 36.5 (927) | 24 (610) | *24G-24 | 38 (17) |
| 16.8 | 24 | 36.5 (927) | 30 (762) | *24G-30 | 42 (19) |
| 20.0 | 24 | 36.5 (927) | 36 (915) | *24G-36 | 45 (20.5) |
| 26.3 | 24 | 36.5 (927) | 48 (1219) | *24G-48 | 50 (22.5) |
| 32.5 | 24 | 36.5 (927) | 60 (1524) | *24G-60 | 57 (26) |
| 38.8 | 24 | 36.5 (927) | 72 (1829) | *24G-72 | 65 (29.5) |
| 45.1 | 24 | 36.5 (927) | 84 (2134) | *24G-84 | 75 (34) |
| 51.4 | 24 | 36.5 (927) | 96 (2438) | *24G-96 | 85 (38.5) |
| 57.7 | 24 | 36.5 (927) | 108 (2743) | *24G-108 | 100 (45.5) |
| 64.0 | 24 | 36.5 (927) | 120 (3048) | *24G-120 | 115 (52) |
| 70.3 | 24 | 36.5 (927) | 132 (3353) | *24G-132 | 130 (59) |
| 76.6 | 24 | 36.5 (927) | 144 (3658) | *24G-144 | 150 (68) |
| EXCHANGE AREA (Sq. ft.) |
NO. OF TUBES | WIDTH in./(mm) | LENGTH in./(mm) | PROTECH MODEL NUMBER | SHIP WT. Lbs./(kg) |
|---|---|---|---|---|---|
| 15.8 | 28 | 42.5 (1080) | 24 (610) | *28G-24 | 40 (18) |
| 19.5 | 28 | 42.5 (1080) | 30 (762) | *28G-30 | 45 (20.5) |
| 23.2 | 28 | 42.5 (1080) | 36 (915) | *28G-36 | 50 (22.5) |
| 30.6 | 28 | 42.5 (1080) | 48 (1219) | *28G-48 | 58 (26.5) |
| 38.0 | 28 | 42.5 (1080) | 60 (1524) | *28G-60 | 65 (29.5) |
| 45.4 | 28 | 42.5 (1080) | 72 (1829) | *28G-72 | 75 (34) |
| 52.8 | 28 | 42.5 (1080) | 84 (2134) | *28G-84 | 85 (38.5) |
| 60.2 | 28 | 42.5 (1080) | 96 (2438) | *28G-96 | 100 (45.5) |
| 67.6 | 28 | 42.5 (1080) | 108 (2743) | *28G-108 | 115 (52) |
| 75.0 | 28 | 42.5 (1080) | 120 (3048) | *28G-120 | 130 (59) |
| 82.4 | 28 | 42.5 (1080) | 132 (3353) | *28G-132 | 150 (68) |
| 89.8 | 28 | 42.5 (1080) | 144 (3658) | *28G-144 | 175 (79.5) |
-
-
-
For use in most alkaline or acid solutions
Vertical or horizontalconfigurations
Every inch of coil surfaceis active exchange area
2-inch thick, low profile design
316 stainless steel, Zirconium, Hastelloy C and Titanium
4.6 square foot to 89.9 square foot of exchange area
100 PSI working pressure (steam or water)
Features & Values
Wide variety of materials available for use in heating or cooling applications for alkaline or acid solutions and rinse tanks. Check solution guide or consult with your chemical supplier for proper sheath material.
Heavy wall, 20 gauge metal tubing available in steel, 316 stainless steel and titanium.
1” diameter tubing and 1” MNPT connection fittings
4.6 square foot to 89.9 square foot of exchange area
Single point connections reduce the potential for leaks and simplify installation.
NOTE: Inlet and outlet connections must be sized
to adequately handle water and steam volume requirements. Generally, larger inlet sizes are needed for grid coils larger than 33 sq. ft. (for steam) and 25 sq. ft. (for water).Safety Features
Integral inlet and outlet manifolds for single point connections greatly reduce the potential forleaks and simplifies installation
Preassure
100 PSI working pressure (steam or water)
Options
Mounting Hangers
Vertical or horizontal configurationsHeavier gauge tubing or pipe
Zirconium, Hastelloy C and other alloys available
Vacuum Breakers
Special riser sizes, fittings,lengths, and configurations
Non-conductive isolator couplings
-
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.