Plastic Immersion Heat Exchanger Precise Heater Surface Finishing
Plastic Immersion-Type Heat Exchanger -Precise Heater
| Teflon(Fluorpolymer) Heating and cooling coils | |||||
|
Exchange area Sq.Ft |
Connections Inch |
Length In./mm |
Width In./mm |
Thickness In./mm |
Model No. |
| 5.5 | 3/4 FNPT | 11.5(292) | 11.5(292) | 2(51) | XC-12-12 |
| 11 | 3/4 FNPT | 15.5(394) | 15.5(394) | 2(51) | XC-16-16 |
| 16.5 | 3/4 FNPT | 17.5(445) | 17.5(445) | 2.36(60) | XC-18-18 |
| 22 | 3/4 FNPT | 19.7(500) | 15.7(400) | 2.36(60) | XC-20-16 |
| 27.5 | 3/4 FNPT | 19.7(500) | 19.7(500) | 2.36(60) | XC-20-20 |
| 33 | 3/4 FNPT | 23.5(597) | 23.5(597) | 2.36(60) | XC-24-24 |
| 38.5 | 3/4 FNPT | 27.5(700) | 23.5(597) | 2.36(60) | XC-28-24 |
| 44 | 3/4 FNPT | 27.5(700) | 27.5(700) | 2.76(70) | XC-28-28 |
| 49.5 | 3/4 FNPT | 31.5(800) | 31.5(800) | 2.76(70) | XC-32-32 |
| 55 | 1 FNPT | 33.9(860) | 33.9(860) | 2.76(70) | XC-34-34 |
| 60.5 | 1 FNPT | 35.5(900) | 31.5(800) | 2.76(70) | XC-36-32 |
| 66 | 1 FNPT | 35.5(900) | 33.9(860) | 2.76(70) | XC-36-34 |
| 71.5 | 1 FNPT | 35.5(900) | 35.5(900) | 2.76(70) | XC-36-36 |
| 77 | 1 FNPT | 39.5(1000) | 33.9(860) | 3.15(80) | XC-40-34 |
| 83.5 | 1 FNPT | 39.5(1000) | 35.5(900) | 3.15(80) | XC-40-36 |
| 89 | 1 FNPT | 39.5(1000) | 39.5(1000) | 3.15(80) | XC-40-40 |
| 94.5 | 1 FNPT | 39.5(1000) | 39.5(1000) | 3.15(80) | XC-41-41 |
| 99 | 1 FNPT | 43.3(1100) | 39.5(1000) | 3.15(80) | XC-43-40 |
| 104 | 1-1/2 FNPT | 43.3(1100) | 39.5(1000) | 3.54(90) | XC-44-40 |
| 110 | 1-1/2 FNPT | 45.3(1150) | 39.5(1000) | 3.54(90) | XC-45-40 |
| 115 | 1-1/2 FNPT | 47.2(1200) | 39.5(1000) | 3.54(90) | XC-47-40 |
| 120 | 1-1/2 FNPT | 47.2(1200) | 39.5(1000) | 3.54(90) |
XC-48-41 |
Further details:
Possible materials: PE-RT,PFA,FEP, PP and PVDF
Temperature range: -22 to 284 °F (depending on the material chosen)
Working pressure range: 45.5 to 232 oF (depending on the material chosen and the operating temperature)
Cooling/heating/condensing
Heating and cooling of corrosive or scale forming fluids and highly concentrated inorganic acids in open tanks
Heating, cooling, condensing or evaporation of corrosive media in vessels
Customized design from modular, pre-manufactured tube sections
10 to 375 ft2 heat transfer surface
For use with water, steam or cooling media
High cooling and heating efficiency Flexible and compact design
Fully corrosion resistant
Safe heat transfer medium
Best in class flow efficiency
Easy maintenance and cleaning More than 30 years of experience
NOTE: Vacuum breakers recommended for fluoropolymer heat exchanger steam heating installations. Please consult factory regarding pressure reduced steam applications.
Custom exchange area and size are available
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.