400mm Petroleum Coke Graphite Electrodes Oxidation Corrosion Resistance
400mm Graphite Electrodes
400mm Graphite Electrode selects high quality petroleum coke, needle coke and so on as raw materials, through forming, roasting, macerating, graphitization and mechanical processing and made, as high quality conductive materials for the arc furnace.
- Product Details
The 400mm Graphite Electrodes select high quality petroleum coke, needle coke and so on as raw materials, through forming, roasting, macerating, graphitization and mechanical processing and made, as high quality conductive materials for the arc furnace.
The 400mm Graphite Electrodes are important conductive materials in the electric smelting industry. They come with good electrical conductivity, thermal conductivity, and have good resistance to oxidation and corrosion at high temperatures. They are widely used in electric arc steel making furnaces, mineral thermal electric furnaces for the production of iron alloys, pure silicon, yellow phosphorus, matte copper , Calcium carbide, etc. They have become an important part of the contemporary raw material industry.
| Factors | Eody Breakage | Nipplc Breakaze | Loosening | Tip Spalling | Bolt Loss | 0xidation | Consuption |
| Honconductor in Charge | ◆ | ◆ | |||||
| Heavy scrap in Charge | ◆ | ◆ | |||||
| Trnsformer Capacity too large | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | |
| Phase imbalance | ◆ | ◆ | ◆ | ◆ | ◆ | ||
| Phase Rotation | ◆ | ◆ | |||||
| Excessive Vibration | ◆ | ◆ | ◆ | ||||
| Clanper pressure too High or too low | ◆ | ◆ | |||||
| Roof Electrode socket disalignment ith clectrodc | ◆ | ◆ | |||||
| Water Sprayed on Electrode above Roof | △ | ||||||
| scrap Preheating | △ | ||||||
| Secondary Voltage too High | ◆ | ◆ | ◆ | ◆ | ◆ | ||
| Secondary Current too High | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | |
| Pover Factor too low | ◆ | ◆ | ◆ | ◆ | ◆ | ||
| 0il Consumption too High | ◆ | ◆ | ◆ | ||||
| Oxygen Consunption tooHigh | ◆ | ◆ | ◆ | ◆ | |||
| long tiae gop fron tapping to tapping | ◆ | ◆ | |||||
| Electrode Dipping | ◆ | ◆ | |||||
| Dirty Joint | ◆ | ◆ | |||||
| Poorly Maintained Lift Plug and Tightening Tod | ◆ | ◆ | ◆ | ||||
| Insufficient Joint Tightening | ◆ | ◆ | ◆ | ||||
| △ Note:AIndictes increased performance. | |||||||
| ◆ Note:Tndicates decreased nerforaanco. | |||||||
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.