Endress Hauser FTL31 Liquiphant Point Level Detection with G1/2 Thread ISO228 Connection
Product Specifications
Attribute Value
Approval Non-hazardous area
Power Supply; Output 10-30VDC; 3-wire PNP
Electrical Connection Valve plug ISO4400 M16, IP65 NEMA Type 4X Encl.
Sensor Design Max. process temperature 150°C/302°F
Sensor Type Compact version 316L Ra<3.2µm/126µin
Process Connection Thread ISO228 G1/2, 316L
Product Description

The Endress+Hauser Liquiphant FTL31 is a reliable point level switch designed for liquid detection in industrial applications across various industries, with particular suitability for machinery applications.

Key Features
  • Compact Design: Smallest vibronic sensor in the market
  • Safety Features: Continuous self-monitoring and reliable switching independent of media properties
  • Easy Operation: No calibration required, plug & play functionality with IO-Link connectivity
  • Robust Construction: Stainless steel housing with process connections via threads
  • Wide Operating Range: Temperature from -40 to +150°C (-40 to +302°F), pressure from -1 to +40bar (-14.5 to 580psi)
  • Certifications: Overfill protection WHG, marine approvals (ABS/LR/BV/DNV), final inspection report EN 10204-3.1
Technical Specifications
Measuring Principle Vibration Liquids
Application Level switch for liquids in tanks, vessels and pipes
Power Supply 20...253V AC/DC, 2-wire or 10...30V DC-PNP 3-wire
Temperature Range Ambient: -40°C to 70°C (-40°F to 158°F)
Process: -40°C to 150°C (-40°F to 302°F)
Pressure Range Vacuum to 40 bar (580 psi)
Process Connections Threads: G1/2, G3/4, G1, MNPT1/2, MNPT3/4, MNPT1, R1/2, R3/4, R1
Certifications CSA C/US, EAC, WHG overfill protection, marine approvals
Endress Hauser FTL31 Liquiphant Point Level Detection Sensor Close-up view of FTL31 sensor with G1/2 thread connection

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company SC Automation Limited
Location Unit 1406B 14/F,The Belgian Bank Building, Nos. 721-725 Nathan Road, Mongkok, Kowloon,Hong kong.
Contact Person Joy chen

Request A Quote

Please check your email address.
Your message must be at least 20 characters.