2.8kA 1.0kA Mtl Intrinsically Safe Barriers SD32X
Product Specifications
Max discharge surge current (Imax) (8/20µs) 20kA (8/20µs) 6.5kA (SD150X and SD275X only)
Lightning impulse current (Iimp) (10/350µs) 2.8kA 1.0kA (SD150X and SD275X only)
Ambient temperature –40°C to +80°C / -40°F to 176°F storage –40°C to +80°C / -40°F to 176°F working
Humidity 5 to 95% RH (non-condensing)
Mounting T-section DIN-rail 35 x 7.5 or 35 x 15mm rail (1.38" x 0.3" x 0.6")
Weight 70g approximately (2.5oz)
Product Description
The Crouse-Hinds series MTL SD range is a series of surge protection devices combining unparalleled packing densities, application versatility, proven reliable hybrid circuitry, simple installation and optional 'loop disconnect' facilities - features which make the range the ultimate surge protection solution for process equipment, I/O systems and communications networks.
The exceptionally high packing densities are the consequence of an ultra-slim footprint for individual modules which can thus "double-up" as feedback terminals. Each module provides full hybrid surge protection for 2 and 3 wire loop protection.
SDX models are available in 7V, 16V, 32V and 55V versions (SD07X, SD16X, SD32X and SD55X respectively) and are suitable for a wide range of applications including THCs, 4-20mA loops, shut-down systems and fire and gas detectors.
Technical Specifications
Model Nominal voltage+ (Un) (Vdc) (Vac) Nominal current (In) (mA) Series resistance (Ω/line) Max. leakage current (µA) Rated voltage *MCOV) (Uc) Voltage protection level (Up) @1kV/µs (V) Residual voltage @isn (V) Bandwidth (frequency) (fG) Special feature
SD07 7 5 250 4.2† 500 7.7 <12 30 25kHz Fuse disconnect
Note: all figures are typical at +25°C unless otherwise stated; *standard fuse; +over full working temperature range; †at 20mA with a 250mA standard fuse; ‡these units need external 3A fuses; ^Signal; **Power & Common; <maximum energizing current depends upon RTD resistance.
Related Part Numbers
HCU16
MTL5521
MTL4546Y
MTL7761PAC
MTL Intrinsically Safe Barrier SD32X product photo

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company SC Automation Limited
Location Unit 1406B 14/F,The Belgian Bank Building, Nos. 721-725 Nathan Road, Mongkok, Kowloon,Hong kong.
Contact Person Joy chen

Request A Quote

Please check your email address.
Your message must be at least 20 characters.