Ultrasound Probe Repair
GE IC5-9-D Ultrasound Transducer Repair Connector Housing And Crystal Array Replacement
GE IC5-9-D Ultrasound Transducer Crystal Array Replacement Cable and Strain Relief Repair Model: GE IC5-9-D Fault Phenomenon: It has been repaired, the connector housing is damaged, the cable is yellow, the image on the machine is seriously missing, interference, and the crystal is broken. Maintenance Plan: Replace connector housing and original crystal (Check whether the cable is faulty when dismantling and repairing.) 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka
Ge M5sc-D Ultrasound Probe Repair Transducer Lens Replacement Cable And Strain Relief
GE M5SC-D Ultrasound Transducer Crystal Array Replacement Cable and Strain Relief Repair Model: GE M5SC-D Fault Phenomenon: Cable and strain relief are aging, lens bubbling. Maintenance Plan: Replace lens, repair cable and strain relief (the matching layer needs to be removed and repaired for lens detection) 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane
GE RIC6-12-D Ultrasound Transducer Dome Replacement And 4D Maintenance
GE RIC6-12-D Ultrasound Transducer Dome Replacement and 4D Maintenance Model: GE RIC6-12-D Fault Phenomenon: 4D error report, the Dome is off, the image and cable can be detected when the error report occured after repair Maintenance Plan: Repair 4D, replace the dome (oil filling). 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain
GE RAB4-8-RS 4D Ultrasound Transducer Repair Cardiovascular Ultrasound Machine
GE RAB4-8-RS 4D Ultrasound Transducer Repair Cardiovascular Ultrasound Machine Model: GE RAB4-8-RS Fault Phenomenon: There is an error for 4D. Suggestion: Repair 4D. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal/Array replacement,Plastic housing repair,Connecting cable repair
GE RAB4-8-D Convex Ultrasound Transducer Probe 4D Repair And Dome Replacement
GE RAB4-8-D Convex Ultrasound Transducer 4D Repair and Dome Replacement Model: GE RAB4-8-D Fault Phenomenon: The dome is damaged and the oil leaks, and the 4D error is reported. Maintenance Plan: Replace the Dome and repair 4D 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal
Samsung L3-12A Ultrasound Transducer Probe Replace Acoustic Lens For Color Doppler
Samsung L3-12A Ultrasound Transducer Probe Replace Acoustic Lens For Color Doppler Model: Samsung L3-12A Fault description: The lens is blistered and the acoustic lens cannot detect. Maintenance scheme: Replace acoustic lens. Common Probe failure 1. Lens: Acoustic lens damage or bulge 2. Cable: the cable is damaged and the shell is cracked 3. Image attenuation: aging attenuation 4. Shadow: dark vertical line 5. Not recognized: probe not recognized 6. Interference: probe
Biosound Biosound CA123 Ultrasound Probe Repair Service Replace Crystal Lens Cable
Biosound Biosound CA123 Ultrasound Probe Repair Service Replace Crystal Lens Cable 1. Type: Curved Array 2.Compatible system: Biosound MyLab 5; Biosound MyLab 15; Biosound MyLab 15XV; Biosound MyLab 20; Biosound MyLab 20XV; Biosound MyLab 20 Plus; Biosound MyLab 25; Biosound MyLab 25 Gold; 90; Biosound MyLab 90 Gold 3. Frequency: 5.0 - 9.0 MHz. 4. Application: Abdominal, Veterinary 5. With 60 days warranty after fixed and 3-5 working days to repair We provide repair service on most common probes
Wisonic L15-4 Ultrasound Transducer Probe Replace Acoustic Lens
Wisonic L15-4 Ultrasound Transducer Probe Replace Acoustic Lens 1. Type: 2D Linear 2. With 60 days warranty after fixed and 3-5 working days to repair Common Probe failure 1. Lens: Acoustic lens damage or bulge 2. Cable: the cable is damaged and the shell is cracked 3. Image attenuation: aging attenuation 4. Shadow: dark vertical line 5. Not recognized: probe not recognized 6. Interference: probe interference 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka
GE RIC5-9W-RS Ultrasound Probe Repair Monitor Dome Crystal
GE RIC5-9W-RS Ultrasound Probe Repair Monitor Dome Crystal 1. Type: Microconvex 2.Compatible system: Voluson i, Voluson e, Voluson S8, Voluson S10, Logiq S6 , Logiq P6 3. Frequency: 5.0-9.0 MHz 4. Application: Abdominal, Anesthesia, Breast, Cardiac, Emergency Medicine, General Imaging, Musculoskeletal, OB/GYN, Pediatrics, Small Parts, Superficial, TCD, Vascular, Venous 5. With 60 days warranty after fixed and 3-5 working days to repair 2D Probe Repair Service Brand GE,
Aloka ASU-1010 Ultrasound Transducer Probe Replace Housing Cover And Crystal
Aloka ASU-1010 Ultrasound Transducer Probe Replace Housing Cover And Crystal Model: Aloka ASU-1010 Fault Phenomenon: The connector cable is aging, the housing cover is deformed and there are gaps, the computer image is seriously missing and interference, the crystal is broken. Maintenance Plan: Replace housing cover and crystal. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector
C5-1 Ultrasound Probe Repair For Cable And Lens Replacement
C5-1 Ultrasound Probe Repair For Cable And Lens Replacement 1. Type: Curved Array 2.Compatible system: GE LogiqBook; GE LogiqBook Xp; GE Logiq e 3. Frequency: 1.0 - 5.0 MHz. 4. Application:Abdominal, Obstetrics, Gynaecology 5. With 60 days warranty after fixed and 3-5 working days to repair 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane
Hospital C5-2S Ultrasound Transducer Probe For Mindray Replace Crystal And Lens
C5-2S Ultrasound Transducer Probe For Mindray Replace Crystal And Lens 1. Type: Curved Array 2.Compatible system: Mindray TE5, M7 3. Frequency: 1.3 MHz. - 5.7 MHz. 4. Application: Abdomen, OB/GYN, Urology 5. With 60 days warranty after fixed and 3-5 working days to repair Common Probe failure 1. Lens: Acoustic lens damage or bulge 2. Cable: the cable is damaged and the shell is cracked 3. Image attenuation: aging attenuation 4. Shadow: dark vertical line 5. Not recognized:
L14-6NE Ultrasound Transducer Probe For Mindray Replace Crystal And Lens
L14-6NE Ultrasound Transducer Probe For Mindray Replace Crystal And Lens 1. Type: Linear Array 2.Compatible system: Mindray DC-70; Mindray DC-8; Mindray DC-8 Expert 3. Frequency: 6.0 - 14.0 MHz. 4. Application: Small Parts, Vascular, Musculoskeletal, Pediatrics 5. With 60 days warranty after fixed and 3-5 working days to repair Common Probe failure 1. Lens: Acoustic lens damage or bulge 2. Cable: the cable is damaged and the shell is cracked 3. Image attenuation: aging
Samsung EA2-11AR Ultrasound Transducer Probe Repair Service Cable Lens
Samsung EA2-11AR Ultrasound Transducer Probe Strain Relief Maintenance Model: Samsung EA2-11AR Fault Phenomenon: can not be tested on the machine, the lens is damaged, the strain relief is damaged. Maintenance Plan: Repair the strain relief. Other hot models we can repair: Brand Model Aloka UST-52101 Aloka UST-52105 Aloka UST-5299 Aloka UST-5412 Aloka UST-5413 Aloka UST-9118 Aloka UST-984-5 Aloka UST-9123 Aloka UST-9124 Aloka UST-9130 Biosound Biosound CA541 Biosound Biosound
Maintenance GE RM6C Ultrasound Probe Transducer Repair 4D pencil
Probe Maintenance for GE RM6C Ultrasound Transducer Repair 4D Model: GE RM6C Fault Phenomenon: 4D ocurred error while detection and there are scratches on the housing cover. Suggestion: Repair 4D. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief replacement,Electronic connector repair,Crystal/Array replacement,Plastic
Siemens 18L6 Ultrasound Probe Repair Transducer Lens Replacement
Siemens 18L6 Linear Array Ultrasound Transducer Probe Lens Replacement Model: Siemens 18L6 Fault description: The cable is yellow, the image on the computer has dark shadows, and the lens is blistered. Maintenance scheme: Replace lens. We provide repair service on most common probes (Linear, convex, sector), 3D/4D transducers, and Endocavity/TEE probes. With 10 years experiences on probe repair, our technical engineer team owns the most advanced probe repair processes, which
GE 4C Ultrasound Probe Repair Transducer Maintenance Lens
Probe Maintenance for GE 4C Ultrasound Transducer Lens Replacement Model: GE 4C Fault Phenomenon: The cable and strain relief are aging, the image on the computer has dark shadows, and the lens is blistered and damaged. Suggestion: Replace the lens. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief replacement,Electronic
GE 8C-RS Ultrasound Probe Transducer Maintenance Lens Replacement
Probe Maintenance for GE 8C-RS Ultrasound Transducer Lens Replacement Model: GE 8C-RS Fault Phenomenon: The cable and strain relief are aging, the image on the computer has dark shadows, and the lens is damaged. Suggestion: Replace the lens. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range Membrane/lens replacement,Strain relief replacement,Electronic
Samsung EVN4-8 Ultrasound Probe Repair Transducer Lens Replacement
Samsung EVN4-8 Ultrasound Transducer Probe Lens Replacement Model: Samsung EVN4-8 Fault Phenomenon: The lens is damaged and cannot be detected on the machine. Maintenance Plan: Replace lens. Other hot models we can repair: Brand Model Aloka UST-52101 Aloka UST-52105 Aloka UST-5299 Aloka UST-5412 Aloka UST-5413 Aloka UST-9118 Aloka UST-984-5 Aloka UST-9123 Aloka UST-9124 Aloka UST-9130 Biosound Biosound CA541 Biosound Biosound CA621 Biosound Biosound CA431 Biosound Biosound CA123
GE RIC5-9-D Ultrasound Probe Repair 4D And Replace Dome In Operating Room
GE RIC5-9-D Ultrasound Probe Transducer Maintenance Repair 4D and Replace the Dome Probe Maintenance for GE RIC5-9-D Ultrasound Transducer Repair 4D and Dome Replacement Model: GE RIC5-9-D Fault Phenomenon: The dome is damaged and leaks oil, and the 4d does not work. Suggestion: Repair 4D and replace the dome. 2D Probe Repair Service Brand GE,,Siemens,Hitachi Aloka,Toshiba,Biosound Biosound,Sumsang Medison Service Type Linear,Convex,Phased,Sector,Endocavity Repair Range