MTL Safety Barrier
MTL5544D 24V Repeater Power Supply for HART Transmitters
96ma 24v MTL Safety Barrier MTL5544D Repeater Power Supply Key Attributes Attribute Value Number of channels One Temperature drift < 0.8µA/°C Response time Settles to within 10% of final value within 50µs Communications supported HART (terminals 1 & 2, output Ch 1 only) LED indicator Green: power indication Maximum power dissipation within unit 96mA at 24V dc Product Overview MTL5544D REPEATER POWER SUPPLY The MTLx544D provides a fully-floating dc supply for energising a
MTL5582B Resistance Isolator MTL Safety Barrier For 10Ω To 400Ω RTDs
10ohm To 400ohm MTL5582B Resistance Isolator Product Attributes Number of channels One Resistance source 2-, 3-, or 4-wire* RTDs to BS 1904/DIN 43760 (100Ω at 0°C) *user selectable by switches (factory set for 3-wire) Resistance range 10Ω to 400Ω Output configuration 2, 3 or 4 wires (independent of mode selected for hazardous area terminals) LED indicator Green: power indication Maximum power dissipation within unit 0.8W at 24V 1.0W at 35V Product Description MTL5582B
MTL5511 NAMUR Proximity Detector Interface 24V 25mA
MTL5511 Switch Proximity Detector Interface 25mA 24V Key Specifications Attribute Value Number of channels One Hazardous-area input Inputs conforming to BS EN60947-5-6:2001 standards for proximity detectors (NAMUR) Safe-area output Single pole relay with changeover contactsNote: reactive loads must be adequately suppressed Maximum current consumption 25mA at 24V Power dissipation within unit 0.6W at 24V LED indicator Green: power indication Yellow: channel status, on when
MTL5531 Vibration Transducer Interface 2-Wire 3.3mA
CE 3.3mA MTL5531 Vibration Transducer Interface 2 Wire Product Specifications Attribute Value Sensor type 2- or 3-wire vibration transducer Hazardous-area input Input impedance (terminals 2 & 3): 10kΩ Signal range Minimum –20V, maximum –0.5V Temperature coefficient ±50ppm/°C (10 to 65°C) ±100ppm/°C (–20 to 10°C) Safe-area output impedance
MTL Safety Barrier TP48-3-N-NDI Surge Protection 20kA EN 61643-21
USA EN 61643-21 MTL Safety Barrier TP48-3-N-NDI Key Specifications Attribute Value Leakage current Less than 1µA at max. working voltage Electrical Safety To BS EN 61643-21 for surge protection devices Ambient temperature -40°C to +85°C (-40°F to +185°F) (working)-40°C to +85°C (-40°F to +185°F) (storage) Humidity 5% to 95% RH (non-condensing) Bandwidth 1MHz Weight 175g (6.2oz) Product Overview The MTL Safety Barrier TP48-3-N-NDI provides superior protection for 2, 3, and 4
SD32X MTL Safety Barrier 2.8kA Surge Protection DIN Rail Mount Intrinsically Safe Barriers
2.8kA 1.0kA Mtl Intrinsically Safe Barriers SD32X Product Specifications Max discharge surge current (Imax) (8/20µs) 20kA (8/20µs) 6.5kA (SD150X and SD275X only) Lightning impulse current (Iimp) (10/350µs) 2.8kA 1.0kA (SD150X and SD275X only) Ambient temperature –40°C to +80°C / -40°F to 176°F storage –40°C to +80°C / -40°F to 176°F working Humidity 5 to 95% RH (non-condensing) Mounting T-section DIN-rail 35 x 7.5 or 35 x 15mm rail (1.38" x 0.3" x 0.6") Weight 70g approximate
MTL HCU16 HART Connection Unit Safety Barrier 0.5KG England
0.5KG England MTL Safety Barrier HART Connection Unit HCU16 MTL Instrument Product Specifications Attribute Value Leading Time On Request Dimensions 1.58 Cm X 10.98 Cm X 12.36 Cm Country Of Origin England Product Name Instrument HART Connection Unit Product Type HCU16 Manufacturer MTL Net Weight 0.5KG Shipping Weight 1.5KG HCU16 MTL Instrument HART Connection Unit The HCU16 HART Connection Unit connects to 16 general purpose field instruments while maintaining channel-to