Fully Automatic CT PT Testing Equipment for Current and Potential Transformer

Price Negotiable
Price: Negotiable
MOQ: 1 set Fully Automatic CT PT Testing Equipment
Delivery Time: 15 days
Brand: AI
Product Description

Introduction:

Fully Automatic CT PT Testing Equipment is used to measure all kinds of current transformer and voltage transformer.

It can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one time test.

Fully Automatic CT PT Testing Equipment can automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.

 

 

Application:

Tests for current transformer Tests for voltage transformer Applications for CTPT analyzer
Excitation curve and parameters test Turns ratio test CT nameplate check
Turns ratio test Polarity test CT parameters check in work burden
Ratio and phase error test Secondary burden test CT transient parameters analysis
Polarity mark check Coil resistance test CT ratio and phase error calibration
Coil resistance measurement Ratio error, phase angle error test PT routine test
Secondary loop burden measurement    
Error line curve test for protection CT    
Transient CT parameters test    
CT nameplate guess    
Saturation hysteresis loop curve measurement    
 

 

Features:

  1. Fully Automatic CT PT Testing Equipment can evaluate test results according to selected standards.
  2. Make word report for test result.
  3. Make word reports one time for multi-group test records on the PC.
  4. Fully Automatic CT PT Testing Equipment can calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
  5. Compare excitation curves with saved excitation curves in the same window.

 

Specifications:

  • Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
  • Power supply: AC220V±10%, 50/60Hz±10%
  • Voltage output: 0.1~180V (AC)
  • Current output: 0.001~5A(RMS)
  • Power output: 500VA
  • Maximum knee voltage measurement: 45KV
  • PT ratio error measurement: typical error <0.05%, maximum error<0.1%
  • PT phase angle measurement: maximum error < 3min
  • Memory capacity: >1000 groups test results
  • Working condition: temperature: -10℃~50℃, humidty: ≤90%
  • Size: 485mm×356mm×183mm, weight: <15kg

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Advanced Instruments Co.,Limited
Location Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China
Contact Person Sandy

Request A Quote

Please check your email address.
Your message must be at least 20 characters.