TD3810 / TD3810R Field Detector Two / Three Phase For Three Phase Power Devices

Price Negotiable
Price: negotiation
MOQ: negotiation
Delivery Time: Negotiable
Brand: TUNKIA
Product Description
TD3810/TD3810R Field Detector for Three-Phase Power Devices
 

Introduction

  • TH3810/TH3810R are two three-phase AC standard instruments, with accuracy of 0.01% and 0.02%.

  • It can simultaneously measure multiple electrical parameters in an measuring circuit, such as voltage, current, frequency, phase, harmonic, active power/electric energy, reactive power/electric energy, apparent power, power factor, etc.

  • Fundamental frequency of TH3810: 45 Hz ~ 65 Hz; Fundamental frequency of TH3810R: 45 Hz ~ 400 Hz, it meets the requirements of the new national standard and R46 directive for electric energy measurement

  • Applied to calibrate AC standard source, and can be used as a standard for electric energy metering.

Features

  • Wide range of direct current measurement: a pair of terminals can be used to measure the wide range AC current measurement.

  • The minimum current measurement of TH3810R is as low as 0.2mA, which can check the accuracy and stability of power / energy of the device and standard meter at the minimum starting current.

  • Harmonic Analysis: Measure 2nd ~ 127th harmonic, analyze harmonic content and total harmonic distortion, and draw harmonic histogram.

  • Waveform Display: Oscilloscope function can display the waveform of the measured electrical parameters in real time.

  • High reliability, the switch will not damage the instrument in a limit state (e.g. 500 V, 100A), but can also ensure the value accurate.

  • Statistics and Analysis of Data: Calculate the electrical parameters such as the maximum, minimum, average, difference, standard deviation, etc.

  • Magnetic Field Measurement: Measure the magnetic induction or other weak AC magnetic field at the measured meter position of the electric energy meter calibrators.

  • Meter Potential Difference Measurement: Measure the meter potential difference of the calibrators for AC electrical energy meters.

  • Temperature and humidity measurement.

  • Clock Measurement: A built-in PPS standard second pulse I/O function can calibrate time for the measured devices with the ability to sustain voltage of 380 V.

  • Excellent Human-computer Interaction: LCD touch screen, more intuitive of value display and easier operation. it is equipped with RS232, USB, RJ45 interfaces, which is convenient to set up a full-automatic measurement system.

  • The proprietary software that meets the requirements of JJG 597-2005, supports on-site to analyze errors, record data and print reports for the measured devices.

Specification

 

Three-Phase Voltage Measurement

Range Resolution Accuracy (k = 2) ppm*RD +ppm*RG Temperature Coefficient (/℃)
0.02% 0.01% TD3810 TD3810R
60 V 10 μV 60 + 40 30 + 20 <1.0 <0.5
120 V 0.1 mV 60 + 40 30 + 20 <1.0 <0.5
240 V 0.1 mV 60 + 40 30 + 20 <1.0 <0.5
480 V 0.1 mV 60 + 40 30 + 20 <1.0 <0.5

Measuring Range: 6 V ~ 528 V

Range Switching: Automatic or Manual

 

Three-phase Current Measurement

Range Resolution Accuracy (k = 2) ppm*RD +ppm*RG Temperature Coefficient (/℃)
TH3810(0.02%) TH3810(0.01%) TH3810R(0.02%) TH3810R(0.01%) 0.02% 0.01%
5 mA 1 nA —— —— 600 + 400 300 + 200 < 10 < 5.0
10 mA 10 nA 300 + 200 150 +100 300 + 200 150 +100 < 5.0 < 3.0
20 mA 10 nA 150 + 100 80 + 50 150 + 100 80 + 50 < 2.5 < 1.5
50 mA 10 nA 60 + 40 30 + 20 60 + 40 30 + 20 < 1.0 < 0.5
100 mA 0.1 μA 60 + 40 30 + 20 60 + 40 30 + 20 < 1.0 < 0.5
200 mA 0.1 μA 60 + 40 30 + 20 60 + 40 30 + 20 < 1.0 < 0.5
500 mA 0.1 μA 60 + 40 30 + 20 60 + 40 30 + 20 < 1.0 < 0.5
1 A 1 μA 60 + 40 30 + 20 60 + 40 30 + 20 < 1.0 < 0.5
2 A 1 μA 60 + 40 30 + 20 60 + 40 30 + 20 < 1.0 < 0.5
5 A 1 μA 60 + 40 30 + 20 60 + 40 30 + 20 < 1.0 < 0.5
10 A 10 μA 60 + 40 30 + 20 60 + 40 30 + 20 < 1.0 < 0.5
20 A 10 μA 60 + 40 30 + 20 60 + 40 30 + 20 < 1.0 < 0.5
50 A 10 μA 60 + 40 30 + 20 60 + 40 30 + 20 < 1.0 < 0.5
100 A 0.1 mA 60 + 40 30 + 20 60 + 40 30 + 20 < 1.0 < 0.5
  • Measuring Range of TH3810: 1 mA ~ 120 A

  • Measuring Range of TH3810R: 0.5 mA ~ 120 A

  • Range Switching: Automatic or Manual

 

Frequency and Phase

Model Frequency (Hz)

Accuracy

(k = 2)

Phase

(I ≥ 50 mA)

Accuracy (k = 2) (Hz)
45≤F≤120 120≤F≤400
TH3810(0.02%) 45.000 0 ~ 65.000 0 50 ppm*RD 0.000° ~ 359.999° 0.01 ° ——
TH3810(0.01%) 45.000 0 ~ 65.000 0 50 ppm*RD 0.000° ~ 359.999° 0.005 ° ——
TH3810R(0.02%) 45.000 0 ~ 400.000 50 ppm*RD 0.000° ~ 359.999° 0.01 ° 0.02 °
TH3810R(0.01%) 45.000 0 ~ 400.000 50 ppm*RD 0.000° ~ 359.999° 0.005 ° 0.01 °

 

Three-phase Power and Electric Energy

Parameter Type U Range I Range Accuracy (k = 2) of Power and Electric Energy at Diff. Frequency (Hz)
0.02% 0.01%
45≤F≤120(65) 120<F≤400 45≤F≤120(65) 120<F≤400

Active Power/

Electric Energy

|cosφ| ≥0.5

Reactive Power/

Electric Energy

|sinφ| ≥0.5

TH3810 30 V≤U≤480 V 20 mA≤I≤120 A 0.02%*RD —— 0.01%*RD ——
10 mA≤I≤20 mA 0.05%*FS   0.02%*FS  
1 mA≤I≤10 mA 0.1%*FS —— 0.05%*FS ——
TH3810R 30 V≤U≤480 V 20 mA≤I≤120 A 0.02%*RD 0.05%*RD 0.01%*RD 0.02%*RD
10 mA≤I≤20 mA 0.05%*FS 0.1%*FS 0.02%*FS 0.05%*FS
5 mA≤I≤10 mA 0.1%*FS 0.2%*FS 0.05%*FS 0.1%*FS
0.5 mA≤I≤5 mA 0.2%*FS 0.5%*FS 0.1%*FS 0.2%*FS
  • Notes: ①: The superior limit of operating frequency of TH3810 is 65Hz;

  • Power / Electric Energy Measuring Range: Combination of DC voltage range and DC current range.

  • Power Factor Measuring Range: -1.000 00…0.000 00…1.000 00

  • Output of Standard Electric Energy Pulse: High frequency FS @ 60 kHz, low frequency FS @ 6 Hz.

  • Input of Standard Electric Energy Pulse: Frequency≤200 kHz, input level 0…3.3 V…24 V.

 

Meter Potential Difference and Clock

  • Range: 5 mV,50 mV,500 mV,5 V

  • Accuracy: 0.2 mV

  • It can withstand 250V voltage continuously. PPS standard second pulse output / measurement.

  • Accuracy: 0.1 ppm

 

Device Magnetic Field Measurement

  • Range: 100 μT,1 mT, 5-digit display

  • Accuracy: 0.5%

  • Probe: Three-axis magnetic field sensing probe

  • Remark:It is used to measure the magnetic flux density or environmental magnetic field at the position of the meter being tested.