Test Finger Probe
8mm Cylindrical Rod Test Probe For Blender As Per IEC 60335-2-14 Clause 20.102
Φ8mm Cylindrical Rod Test Probe for Blender as Per IEC60335-2-14 clause 20.102 1. Introduction The Φ8mm cylindrical rod test probe is designed to meet the test requirements of IEC60335-2-14 clause 20.102 and GB4706 clause 20.102, it is applied to check if the blades of hand-held blenders are completely screened from above and unable to touch a flat surface while rotating. The cylindrical rod from any position between the vertical and an angle of 450 to the upperside of the
Similar Test Finger Probe B With 50mm Circular Stop Face IEC 60335-1 Clause 20.2
Similar Test Probe B with 50mm Circular Stop Face IEC60335-1 Clause 20.2 1. Introduction The probe is similar to test probe B of IEC61032 but having a circular stop face with a diameter of 50mm, instead of the non-circular face. The probe is designed to meet the test requirements of IEC60335-1 clause 20.2, it is applied to verify the mechanical strength of enclosures, guards and simliar parts. 2. Specification Model PG-TPB-1 Jointed point size 1 30±0.2 Jointed point size 2 60
Nylon Handle Test Finger Probe UL507 Standard For Testing The Accessability To Live Parts
UL Accessability Test Probe as Per UL1278 (PA140A) and UL507 (PA170D) 1. Standard conforms to UL507 (PA170D) , UL1278 (PA140A) , UL398 (PA170B) 2. Application In determining if an opening in an enclosure is acceptable. Probe for uninsulated live parts UL1278 (PA130A) Probe for film-coated wire of fan UL507 (PA135A) 3. Specification Rigid finger length 101.6mm (4 inch) Rigid finger diameter Φ25.4mm (1 inch) Head radius R12.7MM (1/2 inch) Tail diameter 31.5mm (1_1/4 inch)
UL Accessability Test Probe As Per UL507 PA135A And UL1278 PA130A
UL Accessability Test Probe as Per UL507 (PA135A) and UL1278 (PA130A) 1. Standard conforms to UL507 (PA135A) and UL1278 (PA130A) 2. Application In determining if an opening in an enclosure is acceptable. Probe for uninsulated live parts UL1278 (PA130A) Probe for film-coated wire of fan UL507 (PA135A) 3. Specification Rigid finger length 101.6mm (4 inch) Rigid finger diameter Φ12.7mm (1/2 inch) Head length 14.3mm (9/16 inch) Head radius R4.8mm (3/16 inch) Tail diameter 191.mm
Steel Test Pin Test Finger Probe With Nylon Handle As Per BS1363-1 Figure 1
Steel Test Pin with Nylon Handle as Per BS1363-1 Figure 1 1. Introduction The test pin meets the requirements of BS1363-1 clause 12.6.1 and figure 1.The test pin meets the requirements of BS1363-1 clause 12.6.1 and figure 1. 2. Parameters Pin diameter 0.95-1.00mm Diameter of insulating material 7.95-8.00mm Pin length 19.95-20.00mm Handle diameter 19.95-20.00mm Handle length 49-51mm Diameter of insulating material 7.95-8.00mm Length of insulating material 29.8-30.2mm 3. Figure
UL60335-2-24 Articulated Probe With Flat And Cone Shaped Hand 3.5-4.5 Year Age
UL60335-2-24 Articulated Probe with Flat and Cone Shaped hand 3.5-4.5 Year Age 1. Introduction The articulated probe meets the requirements of UL60335-2-24 Annex 101. DVA and figure 101. DVA.1. It’s used to hazard assessment for moving parts and probe to simulate access to hazardous parts by 3.5-4.5 year old Children’s hand. 2. Parameter: Item Dimension description Dimension (mm) A Middle finger length, 95 percentile 55 B Middle finger diameter, 5 percentile 9.1 C Hand length