Ultrasound Machine Repair
GE Logiq E9 Ultrasound Machine Repair Touch Screen Flower Screen
GE Logiq E9 Ultrasound Machine Repair Touch Screen Flower Screen 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: The device can enter the system normally. Except for the touch screen blurred screen, other functions are basically normal. It is judged that the touch screen is faulty. 4. Solutions: replace the touch screen Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 motherboard
Bisound Biosound Mylab Series CPU Mainboard 9501361000
Repair Bisound MyLab 15/25/30/40/50 mainboard 9501361000 1. Part number: 9501361000/9501361/ 9501080 2. Compatible with Bisound MyLab 15/25/30/40/50 Ultrasound 3. With 60 days warranty 4. Maintenance time: 2-4 days Other ultrasound parts related to Biosound that we can offer: Brand System Description Biosound Mylab 20 plus/30/40 CPU mainboard 9501361000 Biosound MyLab 25 power board 9501083010 4271440192 Biosound MyLab 25 Doppler PCB board 8607300660 8607300670 Biosound MyLab
Doppler Ultrasound Machine Repair Siemens X300 Medical Equipment Assemble
Siemens X300 System Reports Error Fault Phenomenon When using the hollow pressure machine suddenly standby, after a few seconds to restart. This happens again and again. Fault analysis and Troubleshooting Analysis of air compressor standby reasons under normal conditions: First, the air pressure of the air compressor storage tank reaches the upper limit of pressure; Secondly, the external air source is connected to the ventilator. When the fault occurs, the pressure displayed
GE Voluson E8 Auto Restart Ultrasound Machine Repair Replace Power Supply
GE Voluson E8 Auto Restart Ultrasound Machine Repair Replace Power Supply 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Auto Restart Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE Logiq 400 TLMC 2158390-2 GE
GE Voluson E10 Ultrasound Machine Repair Image Anomaly Replace Rfm Board
GE Voluson E10 Ultrasound Machine Repair Image Anomaly Replace Rfm Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Image Anomaly Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE Logiq 400 TLMC 2158390-2 GE
GE Logiq S8 Ultrasound Machine Repair Occasionally Boot Blue Screen And Crash During Operation
GE Logiq S8 Ultrasound Machine Repair Occasionally Boot Blue Screen And Crash During Operation 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Occasionally Boot Blue Screen And Crash During Operation Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE
ALOKA SSD-3500 Ultrasound Machine Repair Abnormal Driving Voltage Reported
ALOKA SSD-3500 Abnormal driving voltage reported Ultrasound Machine Repair 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Abnormal driving voltage reported Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to Aloka that we can offer: Brand System Description Aloka SSD-1000 CPU EP448902BB Aloka SSD-1000 CPU EP453000 Aloka SSD-1000 power board EU-6025B Aloka SSD-1000 TI
Hitachi HI VISION Ultrasound Machine Repair Replace Cell Board Preirus Image Blurred And Report Error
Hitachi HI VISION Preirus Image Blurred And Report Error Ultrasound Machine Repair Replace Cell Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Image Blurred And Report Error Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related that we can offer: Brand Compatible System Description Hitachi EUB-5500 CW Doppler board EZU-ST5 Hitachi EUB-5500 MAP-A WU8012-2 Hitachi EUB
PM30-38696 Ultrasound Machine Repair Toshiba Aplio 300 400 500 Mainboard
Ultrasound Machine Repair Toshiba Aplio 300/400/500 Mainboard PM30-38696 Repair Toshiba Aplio 300/400/500 Mainboard (P/N: PM30-38696) 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part number: PM30-38696 4.Compatible with Toshiba Aplio 300/400/500 Other ultrasound parts related to Toshiba that we can offer: Brand Compatible System Description Toshiba Famio 5 (SSA-510A) TFT board BSM31-5629 Toshiba Famio 8 SSA-530A PCB board I/O TSB1-20-20226 Toshiba Famio 8 SSA-530A CPU
Abnormal Ultrasound Machine Repair Hitachi Aloka Preirus Occasionally Boot Without Response And Image
Preirus Occasionally Boot Without Response And Image Abnormal Ultrasound Machine Repair Hitachi Aloka 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: Occasionally Boot Without Response And Image Abnormal Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to Hitachi that we can offer: Brand Model Description Hitachi EUB-5500 CW Doppler board EZU-ST5 Hitachi EUB-5500 MAP-A
HD15 Error 0030 When Booting Ultrasound Machine Repair ACB
HD15 Error 0030 When Booting Ultrasound Machine Repair ACB 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: It reports 0030 when it is turned on, and the self-test ACB fails. After replacing the ACB, it can be turned on and used, but the error 0022 is reported when the probe is switched, and the self-test AIM fails again. Various GE/Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range. Other ultrasound parts related to
Aloka F31 Therapy Ultrasound Machine Repair USP EP556600
Hitachi Aloka F31 System Reports Error The parts with high failure rate&available in stock of this machine: 1.RX Beamformer board(EP568900) 2.Mainboard(EP575700BC/EP560800) 3.TX/RS(EP557400/EP557300) 4.BF Beamformer board(EP557400) 5. RX mainboard(EP557500) 6.CONT(EP556700BB) 7.USP(EP556600) 8.Cell Board CPU(EP558800/EU-9148B) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard
Toshiba Aplio 300 Ultrasound Repair Service Report Error BSM31-5629
Toshiba Aplio 300 Ultrasound Repair Service Report Error 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: Report Error Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related to Toshiba that we can offer: Brand Compatible System Description Toshiba Famio 5 (SSA-510A) TFT board BSM31-5629 Toshiba Famio 8 SSA-530A PCB board I/O TSB1-20-20226 Toshiba Famio 8 SSA-530A CPU
EPIQ 5 EPIQ 7 ACQ Acquisition Module Board Maintenance 453561704246
EPIQ 5/EPIQ 7 ACQ Acquisition Module Board Maintenance 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part Number: 453561734844 REV A /453561704246/453561734845/453561734843 4. Compatible for EPIQ5/EPIQ 7 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related that we can repair: Brand System Description Envisor control panel 453561184013 Envisor TR board
HD7 Envisor Ultrasound Machine Repair Power Supply 453561184013
HD7 Envisor Ultrasound Machine Maintenance Repair Power Supply 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Compatible for HD7 Envisor Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related that we can repair: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540-20240 453561448371 Envisor RX/TX M2540-20040 REV C
IU22 IE33 Ultrasound Machine Repair Front End Controller Board
Repair IU22 IE33 Ultrasound Machine Front End Controller Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part Number: 453561278261/453561278266/453561464291/453561153751 4. Compatible for IU22 IE33 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related that we can repair: Brand System Description Envisor control panel 453561184013 Envisor TR board
IU22 IE33 Ultrasound Machine Repair Parts Unified Motherboard
Repair IU22 IE33 Ultrasound Machine Unified Motherboard 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part Number: 453561254492/453561360251/453561244586/453561604293 4. Compatible for IU22 IE33 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related that we can repair: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540
EPIQ 5 Ultrasound Machine Repair Startup Report Error 511 Replace ACQ
EPIQ 5 Startup Report Error 511 Replace ACQ 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: Startup Report Error 511 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540-20240 453561448371 Envisor RX/TX M2540-20040 REV C
Hitachi HI VISION Ultrasound Machine Repair Avius L Probe Switch Key Insensitive
Hitachi HI VISION Avius L Probe Switch Key Insensitive Ultrasound Machine Repair 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Probe Switch Key Insensitive Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related that we can offer: Brand Compatible System Description Hitachi EUB-5500 CW Doppler board EZU-ST5 Hitachi EUB-5500 MAP-A WU8012-2 Hitachi EUB-5500 MAP WB8002-A
EPIQ 5 Report Error 005 Ultrasound Machine Repair Replace ACQ Board
EPIQ 5 Report Error 005 Ultrasound Machine Repair Replace ACQ board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Report Error 005 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related that we can offer: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540-20240 453561448371 Envisor RX/TX M2540-20040 REV C