Guangzhou Rongtao Medical Tech LTD.
                                                                                                           
Verified Supplier
12 Years
Since 2014
Menu
Home Products Ultrasound Machine Repair

Ultrasound Machine Repair

China EP539000BE Ultrasound Machine Repair Aloka Alpha 7 Probe Interface Board for sale Video

EP539000BE Ultrasound Machine Repair Aloka Alpha 7 Probe Interface Board

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Aloka Alpha 7 Probe Interface Board Ultrasound Repair/Spare Part Medical Repair Aloka Alpha 7 Probe Interface Board (EP539000BE) 1. Model: EP539000BE 2. Repair time: 2-4 days 3. We provide 60 days warranty Other ultrasound parts related to Aloka that we can offer: Brand System Description Aloka SSD-1000 CPU EP448902BB Aloka SSD-1000 CPU EP453000 Aloka SSD-1000 power board EU-6025B Aloka SSD-1000 TI board EP401500EH Aloka SSD-1000 EP400600CH Aloka SSD-1000 EP3996 EP3997 Aloka

China IU22 Ultrasonic Machine Repair No Display Failure for sale Video

IU22 Ultrasonic Machine Repair No Display Failure

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 working days

IU22 Ultrasound Device Has No Display Fault phenomenon After pressing the power button, the screen of the IU22 ultrasound device does not display an image. Fault analysis and Troubleshooting The device's non-display failure is roughly divided into two categories: the display or the display cable is faulty; the computer host fails to start normally. After the device is turned on, you can feel the vibration of the host when it is running. Press the shutdown

China IE33 Ultrasonic Diagnostic Instrument Common Fault for sale Video

IE33 Ultrasonic Diagnostic Instrument Common Fault

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 working days

IE33 ultrasonic diagnostic instrument common fault troubleshooting Fault phenomenon During the use of the machine, the image is out of sync (image delay, once every two or three days at the beginning), and there is an eha206 error occasionally. After that, the phenomenon of image delay appears every day. It will be fine after shutdown and restart, but it will appear again after a long time. Troubleshooting Check the fault log, and all the errors point to sip. Focus on

China Repair GE Logiq S8 Ultrasonic Board 5357234 for sale Video

Repair GE Logiq S8 Ultrasonic Board 5357234

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

Repair GE Logiq S8 Ultrasonic BF Board (P/N: 5357234) 1. P/N: 5357234 2. System: Logiq S8 3. With 2-4 days warranty 4. with 60 days warranty Outright/exchange/repair is available for ultrasound parts/Assy. Other ultrasound parts that we can offer: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 APS Power Supply 5140505/5166108/5329667 GE Logiq P5 CPU mainboard 5168431 GE Logiq P5 SYSCONPM 5177848-3 GE Logiq P6 CPU mainboard GE

China Logiq S7 S8 Power Supply Ultrasound Machine Repair CPS 6626600 R02 5413249-3 for sale Video

Logiq S7 S8 Power Supply Ultrasound Machine Repair CPS 6626600 R02 5413249-3

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Repair GE Logiq S7/Logiq S8 Power supply CPS ASSY 6626600 R02, 5413249-3 1. Part number: 6626600 R02, 5413249-3 2. Compatible with GE Logiq S7, Logiq S8 3. With 60 days warranty 4. Maintenance time: 2-4 days Knowledge Point The GE Logiq S7 is a midrange ultrasound machine designed for complete shared service applications from cardiac to GI to 4D OB/GYN. The GE Logiq S7 is extremely light and compact and looks visually very similar to the Voluson S8 and S6. The GE Logiq S7 is

China SSA 580A Toshiba Keyboard Repair , Buttons Failure Digital Keyboard Repair for sale Video

SSA 580A Toshiba Keyboard Repair , Buttons Failure Digital Keyboard Repair

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 working days

Repair and Replace Toshiba SSA-580A numeric Keyboard Brand: Toshiba SSA-580A Model: BSM31-3078 Symptom: Some buttons on the Toshiba SSA-580A numeric keypad are out of order Service Content: Repair and Replace Toshiba SSA-580A New Digital Keyboard (BSM31-3078) Service period: 5 working days Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE

China Clinic Acuson Ultrasound Machine Repair For Display Problem for sale Video

Clinic Acuson Ultrasound Machine Repair For Display Problem

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 working days

Ultrasound Machine SIEMENS Acuson Antares The fault phenomenon After the Antares machine starts, the display stays at the SIEMENS interface, and the machine restarts automatically repeatedly. Failure analysis After testing the other components without any problems, the DVD driver was replaced, the system software was successfully reinstalled, the machine was restarted after the system disc automatically exited, and the firmware was loaded into the ultrasonic two-dimensional

China HD15 ACB Board Medical Ultrasound Machine Repair Solutions for sale Video

HD15 ACB Board Medical Ultrasound Machine Repair Solutions

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

HD15 ACB Board Ultrasound Machine Repair Solutions 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Provide test video after fixed Various GE/Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range. Other ultrasound parts related to that we can offer: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540-20240 453561448371 Envisor RX/TX M2540-20040 REV C Envisor APIO 453561235651 HD3 back end board/mainboard BD

China GE Logiq S6 Ultrasound Machine Repair Displays Virtual Plot And No Echo Zone for sale

GE Logiq S6 Ultrasound Machine Repair Displays Virtual Plot And No Echo Zone

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

GE Logiq S6 Ultrasound Machine Repair Displays Virtual Plot And No Echo Zone 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: Displays Virtual Plot And No Echo Zone Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737

China Report Power Management Error Ultrasound Machine Repair Replace Power Supply GE Voluson E10 for sale

Report Power Management Error Ultrasound Machine Repair Replace Power Supply GE Voluson E10

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

GE Voluson E10 Report Power Management Error Ultrasound Machine Replace Power Supply 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Report Power Management Error Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE

China GE Voluson E10 Image Anomaly Ultrasound Machine Repair RFM423 for sale

GE Voluson E10 Image Anomaly Ultrasound Machine Repair RFM423

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

GE Voluson E10 Image Anomaly Ultrasound Machine Repair Repair RFM423 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: Image is abnormal Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE Logiq 400 TLMC 2158390-2 GE

China Repair  HD11 HD11XE Ultrasound Machine SP Board 453561210154 453561343282 for sale

Repair HD11 HD11XE Ultrasound Machine SP Board 453561210154 453561343282

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Repair HD11 HD11XE Ultrasound Machine SP Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Part Number: 453561210154/453561343282 4. Compatible for HD11/HD11XE Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related that we can repair: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540-20240 453561448371 Envisor RX

China HD15 Report Error 0030 Ultrasound Machine Repair Replace ACB Board for sale

HD15 Report Error 0030 Ultrasound Machine Repair Replace ACB Board

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

HD15 Report Error 0030 Ultrasound Machine Repair Replace ACB Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Report Error Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related that we can offer: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540-20240 453561448371 Envisor RX/TX M2540-20040 REV C

China GE Logiq S7 Imaging Scan Ultrasound Machine Repair Cardiac Probe Frequency for sale Video

GE Logiq S7 Imaging Scan Ultrasound Machine Repair Cardiac Probe Frequency

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

GE Logiq S7 System Reports Error The parts with high failure rate&available in stock of this machine: 1.CPS Power supply(6626600 R02/5413249-3) 2.GBF128 transmitting board(5392446/5392446-3) 3.Mainboard GFS Assy(5371196) 4.BF192 Beamformer(5357234/5357234-2) Common faults of GE ultrasound machine System Faults Solutions LOGIQ 500 No image when scanning far field Check power supply, reinsert the circuit board. Suggest to do metal earthing. LOGIQ 500PRO Artifacts appear in

China Hitachi Aloka HI VISION Avius Ultrasound Machine Repair Vascular Therapy for sale Video

Hitachi Aloka HI VISION Avius Ultrasound Machine Repair Vascular Therapy

Price: Negotiable
MOQ: Negotiable
Delivery Time: 2-4 work days

Hitachi Aloka HI VISION Avius System Reports Error The parts with high failure rate&available in stock of this machine: 1.RDBF(7513907A/7513612/CZK4AB-S12) 2.CONT-B(7513734A/7513640A/CZ84AJ) 3.Cell board(7345930A) 4.RX Board(CZH4AA) 5.TX Board(7513629A) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson

China Ultrasound Repair Service Aloka Prosound Main Board Repair Solutions for sale

Ultrasound Repair Service Aloka Prosound Main Board Repair Solutions

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Ultrasound Repair Service Aloka Prosound Main Board Repair Solutions 1. Repair time: 2-4 days 2. Warranty: 60 days Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range Other ultrasound parts related to Aloka that we can offer: Brand System Description Aloka SSD-1000 CPU EP448902BB Aloka SSD-1000 CPU EP453000 Aloka SSD-1000 power board EU-6025B Aloka SSD-1000 TI board EP401500EH Aloka SSD-1000 EP400600CH Aloka SSD-1000 EP3996

China IU22 Ultrasound Machine Repair No signal at startup repair mainboard for sale

IU22 Ultrasound Machine Repair No signal at startup repair mainboard

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

IU22 Ultrasound Machine Repair No signal at startup repair mainboard 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:No signal at startup Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related that we can offer: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540-20240 453561448371 Envisor RX/TX M2540-20040

China SP Board Ultrasound Machine Repair Solutions For HD15 for sale

SP Board Ultrasound Machine Repair Solutions For HD15

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Repair Solutions For HD15 Ultrasound Machine SP Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Provide test video after fixed Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/maintenance range. Other ultrasound parts related that we can repair: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540-20240 453561448371 Envisor RX/TX M2540-20040 REV C Envisor APIO 453561235651 HD3 back end board/mainboard

China All Probe Images No Echo Ultrasound machine Repair System Aloka ARIETTA 70 for sale

All Probe Images No Echo Ultrasound machine Repair System Aloka ARIETTA 70

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

Aloka ARIETTA 70 All Probe Images No Echo Ultrasound Repair System 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: ALOKA ARIETTA 70 starts slowly, and there is no probe echo area after entering the system, and the lower left corner prompts that the hardware response timed out. Determine system failure. Maintenance result: After replacing the system, booted normally. Various GE/Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair

China GE VIVID E95 Ultrasound Machine Repair Startup Display Flickering Continuously for sale

GE VIVID E95 Ultrasound Machine Repair Startup Display Flickering Continuously

Price: Negotiable
MOQ: 1
Delivery Time: 2-4 work days

GE VIVID E95 Ultrasound Machine Repair Startup Display Flickering Continuously 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: When the device is turned on, the display keeps flickering, the touch screen is black, and it cannot be used normally. 4. Solutions: After the device is turned on, it can enter the ultrasound interface, but the display will keep flickering. When you put your hand on the probe, the image responds normally, and it is judged that it is