Ultrasound Machine Repair
GE Voluson S6 Ultrasound Medical Device Repair RFS Mainboard
GE Voluson S6 System Reports Error The parts with high failure rate&available in stock of this machine: 1.DBM64 2.DBM128 3.BF64 4.BF128 Transformer 5.CPS Power Supply 6.RFS Mainboard Common faults of GE ultrasound machine System Faults Solutions LOGIQ 500 No image when scanning far field Check power supply, reinsert the circuit board. Suggest to do metal earthing. LOGIQ 500PRO Artifacts appear in color flow imaging (betweentimes) Replace ACFP3 board LOGIQ 200E No image on
GE Voluson P8 Sonography Ultrasound Machine Repair BF128 Transformer
GE Voluson P8 Ultrasound Sonography Machine Repair GE Voluson P8 System Reports Error The parts with high failure rate&available in stock of this machine: 1.DBM64 2.DBM128 3.BF64 4.BF128 Transformer 5.CPS Power Supply 6.RFS Mainboard Common faults of GE ultrasound machine System Faults Solutions LOGIQ 500 No image when scanning far field Check power supply, reinsert the circuit board. Suggest to do metal earthing. LOGIQ 500PRO Artifacts appear in color flow imaging
Hitachi Aloka F37 Ultrasound diagnostic Imaging Repair EP575700BC
Hitachi Aloka F37 System Reports Error The parts with high failure rate&available in stock of this machine: 1.RX Beamformer board(EP568900) 2.Mainboard(EP575700BC/EP560800) 3.TX/RS(EP557400/EP557300) 4.BF Beamformer board(EP557400) 5. RX mainboard(EP557500) 6.CONT(EP556700BB) 7.USP(EP556600) 8.Cell Board CPU(EP558800/EU-9148B) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard
Aloka Alpha 5 Laptop Ultrasound Machine Repair Industrial Ultrasonic Transducer
Hitachi Aloka Alpha 5 System Reports Error ALOKA alpha 5 is equipped with advanced front-end technology, original data processing platform,high-capacity digital beam generator (12bit digital beam generator) and other technologies to ensure the high-quality image of all organs in the body.And as well as the varties probes in ALOKA, ALOKA alpha 5 can meet the needs of linical diagnosis and scientific research,At present, ALOKA alpha 5 is used in many hospitals in China. Now we
EPIQ7 Ultrasound Machine Repair 453561734844 453561704246
EPIQ7 Ultrasound Machine Maintenance EPIQ7 System Reports Error Failure phenomenon The EPIQ 7 Ultrasound was suddenly powered off during use, and then suddenly powered off after it was powered on. After encountering two sudden power failures, it turned on again. An abnormal startup failure occurred. The display stayed on the "" interface for a long time, and finally entered the boot interface. Error "511" is reported, and the device cannot be
Toshiba Aplio 400 Vascular Therapy Ultrasound Machine Repair Ultrasonic Scanner
Toshiba Aplio 400 Vascular Therapy Ultrasound Maintenance Toshiba Aplio 400 System Reports Error The parts with high failure rate&available in stock of this machine: 1.Motherboard (BV board)(PM30-38696) 2.TX Board (PM30-38691) 3.RX Board(PM30-39444) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson E6
Toshiba Aplio 500 Fetal Ultrasound Machine Maintenance
Toshiba Aplio 500 Envisor Ultrasound Maintenance Toshiba Aplio 500 System Reports Error The parts with high failure rate&available in stock of this machine: 1.Motherboard (BV board)(PM30-38696) 2.TX Board (PM30-38691) 3.RX Board(PM30-39444) Ultrasound parts that we can repair: Repair List of Featured Ultrasonic Board & Assy Brand System Description Part Number GE Logiq P5 CPU mainboard 5168431 GE Logiq P6 CPU mainboard GE Logiq E9/vivid E9 GFI2 5161631 GE Voluson E6/Voluson
EPIQ 5 Report Error 1226 And After Restart Report Error 503 Replace ACQ Board
EPIQ 5 Report Error 1226 And After Restart Report Error 503 Replace ACQ Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Report Error 1226 And After Restart Report Error 503 Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ mintenance range. Other ultrasound parts related to that we can offer: Brand System Description Envisor control panel 453561184013 Envisor TR board M2540
GE Voluson E10 Ultrasound Machine Repair All Probes Without Echo Repair RFM423
GE Voluson E10 Ultrasound Machine Repair All Probes Without Echo Repair RFM423 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:All Probes Without Echo Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE Logiq 400
GE Voluson E10 Ultrasound Machine powered off Replace Power Supply
GE Voluson E10 Ultrasound Machine powered off Replace Power Supply 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon: Ultrasound Machine powered off Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to GE that we can repair: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE Logiq 400 TLMC
GE Voluson E10 Ultrasound Machine Report Error At Startup Replace Power Supply
GE Voluson E10 Ultrasound Machine Error At Startup Replace Power Supply 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Report Error At Startup Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE Logiq 400 TLMC
GE Logiq P3 Severe Interference In Blood Flow Mode Replace Transmitting board
GE Logiq P3 Severe Interference In Blood Flow Mode Replace Transmitting Board 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Severe Interference In Blood Flow Mode Various GE//Siemens/Toshiba/Hitachi/ Biosound ultrasonic boards are within our repair/ maintenance range. Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737
GE Logiq E9 Ultrasound Machine Repair Image Blurred Replace monitor
GE Logiq E9 Ultrasound Machine Repair Image Blurred Replace monitor 1. Repair time: 2-4 days 2. Warranty: 60 days 3. Fault phenomenon:Image blurred Other ultrasound parts related to GE that we can offer: Brand System Description GE Logiq 200 MSTE board 2266030 GE Logiq 200 mother board 2220786-2 GE Logiq 400 PCONT(high voltage) 2269737 GE Logiq 400 TLMC 2158390-2 GE Logiq 400 VIPP 2245652 GE Logiq 400 MPU ASSY (CPUboard) 2123339 GE Logiq 400 LV3 power board 2211491 GE Logiq
GE Logiq S8 Medical Ultrasound Repair
GE Logiq S8 System Reports Error Failure phenomenon 2D image and blood flow of the machine is abnormal, the blood flow knob is not working good. Failure analysis According to the above failure phenomenon, it can be judged that the image channel of the machine is abnormal. Therefore, it is suspected that there is a problem with the BF channel board. It was also found that the knob& of blood flow section was not working good, so the control panel was disassembled and the
GE Logiq P6 Diagnostic Ultrasound Systems Repair
GE Logiq P6 System Reports Error Failure phenomenon All probes of GE LOGIQ P6 machine have interference in color Doppler mode. Failure analysis and Troubleshooting LOGIQ P6 machine plate structure is simple, plate function integration is high. The color Doppler processing function of the machine is on the SYSCOM motherboard. Generally, this kind of interference is caused by probe failure, external interference or SYSCOM motherboard and APS power supply. Due to the interferenc
GE Logiq P5 Surgical Ultrasound Instrument Repair
GE Logiq P5 System Reports Error Failure phenomenon LOGIQ P5 has no response at start up. Failure analysis Switch ON the POWER, turn ON the main switch at the back of the machine, press the "POWER ON" button, the monitor and keyboard lights are off, the cooling fan is not turned, and the machine has no response.POWER ON cannot be activated when the UPS POWER supply and the main switch of the machine are restarted. The output voltage of UPS measured on fieldis 222V,which
GE HealthCare VOLUSON S8 BF128 5338209-2
GE HealthCare VOLUSON S8 BF128 5338209-2 1. Repair time: 2-4 days 2. Warranty: 60 days 3. New original and full-tested one in perfect working condition Picture Related information VOLUSON S8 GE Healthcare's VOLUSON S8 is a high-end professional four-dimensional Doppler color ultrasound diagnostic instrument, which is widely used in many clinical fields such as obstetrics and gynecology, pediatrics, abdomen, blood vessels, and small organs. Product Overview 1) Make and model:
GE HealthCare VOLUSON S8 DRFM 5497712
GE HealthCare VOLUSON S8 DRFM 5497712 1. Repair time: 2-4 days 2. Warranty: 60 days 3. New original and full-tested one in perfect working condition Picture Related information VOLUSON S8 GE Healthcare's VOLUSON S8 is a high-end professional four-dimensional Doppler color ultrasound diagnostic instrument, which is widely used in many clinical fields such as obstetrics and gynecology, pediatrics, abdomen, blood vessels, and small organs. Product Overview 1) Make and model:
GE HealthCare VOLUSON S8 E-DPI 5722794-2
GE HealthCare VOLUSON S8 E-DPI 5722794-2 1. Repair time: 2-4 days 2. Warranty: 60 days 3. New original and full-tested one in perfect working condition Picture Related information VOLUSON S8 GE Healthcare's VOLUSON S8 is a high-end professional four-dimensional Doppler color ultrasound diagnostic instrument, which is widely used in many clinical fields such as obstetrics and gynecology, pediatrics, abdomen, blood vessels, and small organs. Product Overview 1) Make and model:
GE HealthCare VOLUSON S6 BF64D 5728958
GE HealthCare VOLUSON S6 BF64D 5728958 1. Repair time: 2-4 days 2. Warranty: 60 days 3. New original and full-tested one in perfect working condition Picture GE VOLUSON S6 BF64D is a high-end color ultrasound diagnostic instrument under GE Healthcare, which belongs to the VOLUSON S6 series. This series is well-known in the medical community for its advanced ultrasound imaging technology and wide range of applications. Related information VOLUSON S6 As an advanced color